10. OBJECT DICTIONARY
10 - 32
10.3.6 Point Demand Value (2D68h)
Index
Sub
Index
Name Data
Type
Access
2D68h
0
Point Demand Value
I16
ro
The currently specified point table error No. can be read. The returned values vary depending on the control
mode.
[Pr. PA01]
Control mode
Setting value
_ _ _ 0
Point table mode (pt)
The currently specified point table No. is returned.
While the servo motor is stopped, the value becomes the set value of the Target point
Table (2D60h).
Jog mode (jg)
0 is returned.
_ _ _ 8
Indexer mode (idx)
The currently specified next station No. is returned.
While the servo motor is stopped, the value becomes the set value of the Target point
Table (2D60h).
Jog mode (jg)
The next station No. is returned.
10.3.7 Point Actual Value (2D69h)
Index
Sub
Index
Name Data
Type
Access
2D69h
0
Point Actual Value
I16
ro
The completed point table is returned. The returned values vary depending on the control mode.
Control mode
Setting value
Point table mode (pt)
The completed point table is returned.
After homing completed, "0" is set.
Indexer mode (idx)
The completed station No. is returned. The previous value is held until completion.
10.3.8 Target speed No. (2DD1h)
Index
Sub
Index
Name Data
Type
Access
2DD1h
0
Target speed No.
I16
rw
The command speed, acceleration time constant, and deceleration time constant of the next station to
execute in the indexer mode (idx) is specified with the point table No.
When Profile velocity (6081h), Profile acceleration (6083h), and Profile deceleration (6084h) are all set to
values other than 0, the setting value of 2DD1h is disabled.