10. OBJECT DICTIONARY
10 - 8
Index
Sub
Index
Name and function
Data
Type
Access
Variable
mapping
Default
Range
Units
EEP-
ROM
Param
eter
2C20
0
Machine diagnostic status
[Bit 0 to Bit 3: Friction estimation status at forward
rotation]
0: Normal (During estimation)
1: Normal (Estimation is completed)
2: Warning (the servo motor may rotate in one
direction too frequently.)
3: Warning (the servo motor speed may be too
slow for friction estimation.)
4: Warning (the change in the servo motor speed
may be small for friction estimation.)
5: Warning (the acceleration/deceleration time
constants may be too short for friction
estimation.)
6: Warning (the operation time may not be
enough.)
When warning conditions for 2 to 6 are met at the
same time, the smaller number is returned.
When an estimation is completed even though a
warning has once occurred, the status changes
to "Estimation is completed".
[Bit 4 to Bit 7: Friction estimation status at reverse
rotation]
0: Normal (During estimation)
1: Normal (Estimation is completed)
2: Warning (the servo motor may rotate in one
direction too frequently.)
3: Warning (the servo motor speed may be too
slow for friction estimation.)
4: Warning (the change in the servo motor speed
may be small for friction estimation.)
5: Warning (the acceleration/deceleration time
constants may be too short for friction
estimation.)
6: Warning (the operation time may not be
enough.)
When warning conditions for 2 to 6 are met at the
same time, the smaller number is returned.
When an estimation is completed even though a
warning has once occurred, the status changes
to "Estimation is completed".
[Bit 8 to Bit 11: Vibration estimation status]
0: During estimation
1: Estimation is completed.
[Bit 12 to Bit 15: reserved]
The value at reading is undefined.
U16 ro
Impossible
0 0000h
to
FFFFh
2C21
0
Static friction torque at forward rotation)
Coulomb friction at forward rotation torque is
returned in increments of 0.1%.
I16 ro
Impossible
0 8000h
to
7FFFh
0.1
%
2C22
0
Dynamic friction torque at forward rotation (at
rated speed)
Friction torque at forward rotation torque at rated
speed is returned in increments of 0.1%.
I16 ro
Impossible
0 8000h
to
7FFFh
0.1
%
2C23
0
Static friction torque at reverse rotation
Coulomb friction at reverse rotation torque is
returned in increments of 0.1%.
I16 ro
Impossible
0 8000h
to
7FFFh
0.1
%
2C24
0
Dynamic friction torque at reverse rotation (at
rated speed)
Friction torque at reverse rotation torque at rated
speed is returned in increments of 0.1%.
I16 ro
Impossible
0 8000h
to
7FFFh
0.1
%
2C25
0
Oscillation frequency during motor stop
Vibration frequency during stop/servo-lock is
returned in increments of 1 Hz.
I16 ro
Impossible
0 8000h
to
7FFFh
Hz