4. STARTUP
4 - 15
(2) Operation procedure
1) Turn off the power.
2) Set SW1-1 to "ON (up)" and SW1-2 to "OFF (down)".
Set SW1-1 to "ON (up)" and SW1-2 to "OFF (down)".
1
ON
2
1
ON
2
The test operation mode is not enabled when switches SW1-1and SW1-2 are set during power-
on.
3) Turn on the servo amplifier.
When initialization is completed, the decimal point on the first digit blinks as follows.
After 1.6 s
After 0.2 s
Blinking
If an alarm or warning occurs during the test operation, the decimal point on the first digit also
blinks as follows.
After 0.8 s
After 0.8 s
After 0.2 s
Blinking
Blinking
4) Start operation with the personal computer.
4.5.2 Motor-less operation with a controller
POINT
The servo amplifier need to be connected to the master station (controller) for
motor-less operation.
The motor-less operation cannot be used in the fully closed loop control mode,
linear servo motor control mode, or DD motor control mode.