7. PARAMETERS
7 - 15
7.2 Detailed list of parameters
POINT
For parameters which are not described in this section, refer to chapter 5 of
"MR-J4-_GF_(-RJ) Servo Amplifier Instruction Manual (Motion Mode)".
Set a value to each "x" in the "Setting digit" columns.
The symbols in the control mode column mean as follows:
CP: Point table method
PS: Indexer method
7.2.1 Basic setting parameters ([Pr. PA_ _ ])
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
C
P
P
S
PA01
**STY
Operation
mode
_ _ _ x Control mode selection
Select a control mode.
0: Positioning mode (point table method)
8: Positioning mode (indexer method)
0h
_ _ x _ Operation mode selection
0: Standard control mode
1: Fully closed loop control mode
4. Linear servo motor control mode
6: DD motor control mode
The following settings will trigger [AL. 37 Parameter error].
A value other than "0", "1", "4", and "6" is set in this digit.
A value other than "0" and "6" is set in this digit in the positioning mode (indexer
method).
0h
_ x _ _ For manufacturer setting
0h
x _ _ _
1h
PA06
*CMX
Electronic
gear
numerator
Set an electronic gear numerator. (Refer to section 7.2.6.)
Set the electronic gear within the following range. Setting out of the range will trigger [AL.
37 Parameter error].
1/865 < CMX/CDV < 271471
Setting range: 1 to 16777215
1