9. MANUFACTURER FUNCTIONS
9 - 38
(2) Cam standard position restoration
When the cam axis position restoration target is set to "Cam standard position restoration", and then bit
5 of Control DI2 (2D02h) turns on, the control is switched to the cam control, restoring the "Cam
standard position" based on the "Cam axis current value per cycle" and the "Cam axis feed current
value".
Set the "Cam axis current value per cycle" used for the restoration with cam control data. The feed
current value of when bit 5 of Control DI2 (2D02h) is on is used as "Cam axis feed current value".
The cam standard position is restored to the cam stroke position that corresponds to
"Feed current value - Cam axis one cycle current value".
Cam axis one cycle current value
Cam axis feed current value
Cam standard position
The following is an example of when restoring the cam standard position to start an operation from a
point where both the feed current value and the cam axis current value per cycle are "0" in the cam
whose cam data start position is not "0".
Cam data
start position
Cam data
0
0
Cam axis one cycle current value
Cam axis feed current value
(Feed current value)
Cam standard position