7. PARAMETERS
7 - 14
7.1.9 Network setting parameters ([Pr. PN_ _ ])
No. Symbol
Name
Initial
value
Unit
Detailed
explanation
PN01
For manufacturer setting
0
PN02
CERT
Communication error detection time
0
[ms]
Section
7.2.5
PN03
**NWMD Communication mode setting for CC-Link IE communication
0000h
PN04
**NWNO CC-Link IE communication network number
0
PN05 CERI Communication
error
detection frequency setting
0
[%]
PN06
NOP1
Function selection N-1
0000h
PN07 For manufacturer setting
0000h
PN08
0000h
PN09
0000h
PN10
EIC
Ethernet communication time-out selection
0
[s]
Section
7.2.5
PN11
**IPADA IP address setting A
0000h
PN12
**IPADB IP address setting B
0000h
PN13
**SNMKA Subnet mask setting A
0000h
PN14
**SNMKB Subnet mask setting B
0000h
PN15 For manufacturer setting
0000h
PN16
0000h
PN17
0000h
PN18
**IPAFA
IP address filter A
0000h
Section
7.2.5
PN19
**IPAFB
IP address filter B
0000h
PN20
**IPFRA IP address filter A range setting
0000h
PN21
**IPFRB IP address filter B range setting
0000h
PN22
**IPOAA Operation specification IP address A
0000h
PN23
**IPOAB Operation specification IP address B
0000h
PN24 **IPOR Operation
specification
IP address range specification
0000h
PN25 For manufacturer setting
0000h
PN26
0000h
PN27
0000h
PN28
0000h
PN29
0000h
PN30
0000h
PN31
0000h
PN32
0000h
Summary of Contents for MR-J4-_GF
Page 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Page 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Page 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Page 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Page 271: ...MEMO ...