4. STARTUP
4 - 8
4.3.2 Scrolling display
Axis number will be displayed in hexadecimal.
(1) Normal display
When there is no alarm, the identification number (2 digits) is displayed.
Status
(1 digit)
Identification No.
(2 digits)
"b"
"C"
"d"
: Indicates ready-off and servo-off status.
: Indicates ready-on and servo-off status.
: Indicates ready-on and servo-on status.
(2) Alarm display
When an alarm occurs, the alarm number (two digits) and the alarm detail (one digit) are displayed
following the status display. For example, the following shows when [AL. 32 Overcurrent] is occurring.
Identification No.
(2 digits)
Status
After 0.8 s
Alarm No.
After 0.8 s
Blank
After 0.2 s
Status
(1 digit)
"n": Indicates that an alarm is occurring.
Alarm detail
(1 digit)
Alarm No.
(2 digits)
If an alarm occurs during initial communication through a network, the status, the alarm number (two
digits) and alarm detail (one digit), and the network initial communication status are displayed, in that
order. For example, the following shows when [AL. 16.1 Encoder initial communication - Receive data
error 1] is occurring.
Identification No.
(2 digits)
Status
After 0.8 s
Alarm No.
After 0.8 s
Blank
After 0.2 s
Status
(1 digit)
"n": Indicates that an alarm is occurring.
Alarm detail
(1 digit)
Alarm No.
(2 digits)
After 0.2 s
Network initial
communication
status
After 1.6 s
Blank