9. MANUFACTURER FUNCTIONS
9 - 35
(a) Cam pattern of to-and-fro control
1) Searching from "Cam axis current value per cycle = 0" (Cam data start position = 0)
The cam axis one cycle current value is restored with
the first feed current value that matched.
(The cam axis one cycle current value is not restored
with the second and subsequent feed current values
that matched.)
Search from "Cam axis one cycle current value = 0".
Cam axis one cycle current value
Cam axis feed current value
(Feed current value)
Cam standard position
2) Searching from a value in the middle of the cam axis current value per cycle (Cam data start
position = 0)
Search from a value in the middle, and the cam axis
one cycle current value is restored with the first feed
current value that matched.
(The cam axis one cycle current value is restored with
the second feed current value that matched.)
Search from a value in the middle of the cam axis one
cycle current value.
(Preceding feed current values are searched later.)
Cam axis one cycle current value (Initial setting)
Cam axis one cycle current value
Cam axis feed current value
(Feed current value)
Cam standard position
3) Searching from a value in the middle of the cam axis current value per cycle (Cam data start
position
≠
0)
Search from a value in the middle, and
the cam axis one cycle current value is
restored with the first feed current value
that matched.
Search from a value in the middle of the
cam axis one cycle current value.
Cam axis one cycle current value (Initial setting)
Cam data
start position
Cam axis one cycle current value
Cam axis feed current value
(Feed current value)
Cam standard position