6. SERVO MOTOR DRIVING
6 - 90
(b) Jog operation
The following timing chart shows that a jog operation is started from being stopped at the station No.
0 at servo-on.
Reverse
rotation
0 r/min
Forward
rotation
ON
OFF
ON
OFF
ON
OFF
INP/S_INP
(In-position)
Point actual value
Enabled torque limit value
Controlword bit 4
(Rotation start)
Controlword bit 5
(Direction)
Servo motor speed
Point demand value
1
1 2 3
5
5
0
0
3
Profile velocity
Status DO 5 bit 5
(S_CPO (Rough match))
Status DO 5 bit 6
(S_MEND (Travel completion))
ON
OFF
ON
OFF
(Note)
[Pr. PC77]
Positive torque limit value/
Negative torque limit value
[Pr. PC77]
Positive torque limit value/
Negative torque limit value
[Pr. PC77]
(Note)
4
4
2
100.00 r/min
0
150.00 r/min
Note. A delay time can be set with [Pr. PT39].