9. MANUFACTURER FUNCTIONS
9 - 2
9.2 One-touch tuning
For one-touch tuning, refer to "MR-J4-_GF_(-RJ) Servo Amplifier Instruction Manual (Motion Mode)". Using
One-touch tuning mode (2D50h) allows one-touch tuning from the master station (controller).
(1) Related object
Index Sub Access
Name
Data
Type
Default Description
2D50h
0
rw
One-touch tuning mode
U8
0
Setting "1" to "3" starts one-touch tuning.
After one-touch tuning is completed, the
setting value automatically changes to
"0".
0: During one-touch tuning stop
1: Basic mode
2: High mode
3: Low mode
2D51h
0
ro
One-touch tuning status
I8
0
Regardless of whether one-touch tuning
is properly completed or not, the setting
value changes to 100% at the
completion.
Unit: %
2D52h
0
wo
One-touch tuning Stop
U16
0
Writing "1EA5h" stops one-touch tuning.
Writing a value other than "1EA5h" will
trigger the error code "CCD4h".
2D53h
0
wo
One-touch tuning Clear
U16
0
The parameter changed in one-touch
tuning can be returned to the value
before the change.
0000h: Restores the initial value
0001h: Restores the value before one-
touch tuning
The setting value of the restored
parameter is stored to the EEP-ROM.
2D54h
0
ro
One-touch tuning Error Code
U16
0
The following shows the details of the
one-touch tuning error codes.
0000h: Finished normally
C000h: Tuning canceled
C001h: Overshoot exceeded
C002h: Servo-off during tuning
C003h: Control mode error
C004h: Time-out
C005h: Load to motor inertia ratio
misestimated
C00Fh: One-touch tuning disabled
Summary of Contents for MR-J4-_GF
Page 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Page 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Page 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Page 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Page 271: ...MEMO ...