N9030B PXA Signal Analyzer Service Guide 239
Analog/Digital IF Troubleshooting
A3 Digital IF Assembly Theory of Operation
The signal then passes through a 30 MHz to 90 MHz tripler. A 0 to 5V, 30
MHz square wave is generated. Capacitors form a single-pole band pass
filter to select the 3rd harmonic, 90 MHz.
Noise Source Voltage Regulator
Various external noise sources can be connected to the rear panel of the
PXA Signal Analyzer. These noise sources require a very accurate 28 volt DC
power supply.
The 28 volt BNC output connector is used with the 346 series noise sources.
The Smart Noise Source (SNS) interface includes power switching for the
28 volt and 15 volt power supply. In addition, it has buffers to interface to
the SNS I2C bus for control and read back of ENR data automatically. The
SNS connector is used with the SNS series noise sources.
DSP
The signal from the ADC is sent to the Digital Signal Processor.
Digital Bus Common Mode Filtering
The Digital Bus is a real time digital interface. It is sometimes referred to as
Messenger or LVDS. The implementation on the Digital IF is unidirectional,
meaning it can only source data, not receive it. Common mode filtering is
required to translate the digital ground referenced signals to analog ground
at the rear panel.
Summary of Contents for N9030B
Page 4: ...4 ...
Page 14: ...14 N9030B PXA Signal Analyzer Service Guide Contents ...
Page 342: ...342 N9030B PXA Signal Analyzer Service Guide Hardware Options Option RTS Streaming ...
Page 344: ...344 N9030B PXA Signal Analyzer Service Guide Block Diagrams Block Diagrams Block Diagrams ...
Page 572: ...572 N9030B PXA Signal Analyzer Service Guide Post Repair Procedures Post Repair Procedures ...
Page 612: ...612 N9030B PXA Signal Analyzer Service Guide Instrument Software Software Updates ...