Limit Testing
12-23
Remote limit testing
Limit commands
Table 12-1
summarizes remote commands to control limit testing parameters, while
Table
12-2
summarizes commands to control the Digital I/O port bit parameters for limit testing.
See
Section 18
, “
CALCulate2
” and “
SOURce2
,” for more details on these commands.
Table 12-1
Limit commands
Command*
Description*
:CALCulate2:FEED <name>
Select limit test input path (name = CALCu-
late[1], VOLTage, CURRent, or RESistance).
:CALCulate2:DATA?
Acquire limit test data.
:CALCulate2:LIMit:COMPliance:FAIL <name>
Set Limit 1 fail condition. Name = IN (fail into
compliance) or OUT (fail out of compliance).
:CALCulate2:LIMitX:LOWer <n>
Specify lower Limit X; X = 2, 3, 5-12 (n = limit).
:CALCulate2:LIMitX:UPPer <n>
Specify upper Limit X; X = 2, 3, 5-12 (n = limit).
:CALCulate2:LIMit[1]:COMPliance:SOURce2
<NRf> | <NDN>
Specify limit 1 fail bit pattern. (NRf | NDN =
pattern).
:CALCulate2:LIMitX:LOWer:SOURce2 <NRf> |
<NDN>
Specify lower Limit X fail bit pattern for grading
mode; X = 2, 3, 5-12 (NRf | NDN = bit pat-
tern).
:CALCulate2:LIMitX:UPPer:SOURce2 <NRf> |
<NDN>
Specify upper Limit X fail bit pattern for grading
mode; X = 2, 3, 5-12 (NRf = bit pattern).
:CALCulate2:LIMitX:PASS:SOURce2 <NRf> |
<NDN>
Specify pass pattern for sorting mode (NRf |
NDN = bit pattern).
:CALCulate2:LIMit[1]:STATe <state>
Enable/disable Limit 1 test (state = ON or OFF).
:CALCulate2:LIMitX:STATe <state>
Enable/disable Limit X test; X = 2, 3, 5-12
(state = ON or OFF).
:CALCulate2:LIMit[1]:FAIL?
Query Limit 1 test result (0 = pass, 1 = fail).
:CALCulate2:LIMitX:FAIL?
Query Limit X test result; X = 2, 3, 5-12 (0 =
pass, 1 = fail).
:CALCulate2:CLIMits:PASS:SOURce2 <NRf> |
<NDN>
Specify pass bit pattern (NRf | NDN = pattern).
Sorting mode only if limits 2, 3 and 5-12 dis-
abled.
:CALCulate2:CLIMits:FAIL:SOURce2 <NRf> |
<NDN>
Specify fail bit pattern for sorting mode (NRf |
NDN = pattern).
:CALCulate2:CLIMits:PASS:SMLocation <location>
Specify pass source memory location. Location =
NRf (memory #) or NEXT (next location).
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for SourceMeter 2400
Page 589: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 591: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 592: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...