![Infineon Technologies XC2200 User Manual Download Page 443](http://html1.mh-extra.com/html/infineon-technologies/xc2200/xc2200_user-manual_2055439443.webp)
XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-183
V2.1, 2008-08
SCU, V1.13
6.8.8.3
Output Control Registers EXOCONy
These registers control the outputs of the Output Gating Unit y (y = 0..3).
EXOCON0
External Output Trigger Control 0 Register
SFR (FE30
H
/18
H
)
Reset Value: 0000
H
EXOCON1
External Output Trigger Control 1 Register
SFR (FE32
H
/19
H
)
Reset Value: 0000
H
EXOCON2
External Output Trigger Control 2 Register
SFR (FE34
H
/1A
H
)
Reset Value: 0000
H
EXOCON3
External Output Trigger Control 3 Register
SFR (FE36
H
/1B
H
)
Reset Value: 0000
H
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
IPEN
3
IPEN
2
IPEN
1
IPEN
0
0
GP
PDR
GE
EN
ISS
rw
rw
rw
rw
r
rw
rh
rw
rw
Field
Bits
Type
Description
ISS
[1:0]
rw
Internal Trigger Source Selection
This bit field defines which input is selected as
peripheral trigger input for OGUy. The possible input
signals are given in
.
00
B
The peripheral trigger function is disabled
01
B
Input ERU_OGUy1 is selected
10
B
Input ERU_OGUy2 is selected
11
B
Input ERU_OGUy3 is selected
GEEN
2
rw
Gating Event Enable
Bit GEEN enables the generation of a trigger event
when the result of the pattern detection changes from
match to miss or vice-versa.
0
B
The event detection is disabled
1
B
The event detection is enabled
PDR
3
rh
Pattern Detection Result Flag
This bit represents the pattern detection result.
0
B
A pattern miss is detected
1
B
A pattern match is detected