SCU, V1.13
L2RSTEN
14
rwh
Level Threshold 2 Reset Request Enable
This bit defines if a reset request trigger is requested
if the comparison check was successful. When a
check is successful is defined via bit L2ALEV.
0
B
No reset is requested
1
B
An reset is requested
L2ASEN
15
rwh
Level Threshold 2 Asynchronous Action Enable
This bit defines if asynchronous action can be
performed if the comparison check was successful.
When a check is successful is defined via bit
L2ALEV.
0
B
No asynchronous actions are performed
1
B
Asynchronous actions can be performed