detection where the actual status of the input is important (enabling both edge detections
is not useful in this mode).
The output of the status flag is connected to all following Output Gating Units (OGUy) in
parallel (see
) to provide
pattern detection capability of all OGUy
units
based on different or the same status flags.
In addition to the modification of the status flag, a trigger pulse output TRxy of ETLx can
be enabled (by bit EXICONx.PE) and selected to
trigger actions in one of the OGUy
units. The target OGUy for the trigger is selected by bit field EXICON.OCS.
The trigger becomes active when the selected edge event is detected, independently
from the status flag EXICONx.FL.