XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-171
V2.1, 2008-08
SCU, V1.13
6.8.5
Connecting Matrix
The connecting matrix distributes the trigger signals (TRxy) and status signals
(EXICONx.FL) from the different ETLx units between the OGUy units. In addition, it
receives peripheral trigger signals that can be OR-combined with the ETLx trigger
signals in the OGUy units.
provides a complete overview of the connections
between the ETLx and the OGUy units.
Figure 6-27 Connecting Matrix between ETLx and OGUy
OGU0
ERU_ETL_OGU_Overview.vsd
ETL0
ETL1
ETL2
ETL3
TR00
TR01
TR02
TR03
EXICON0.FL
TR10
TR11
TR12
TR13
EXICON1.FL
TR20
TR21
TR22
TR23
EXICON2.FL
TR30
TR31
TR32
TR33
EXICON3.FL
Pattern
Detection
Inputs
Trigger
Inputs
TRx0
OGU1
Pattern
Detection
Inputs
Trigger
Inputs
TRx1
OGU3
Pattern
Detection
Inputs
Trigger
Inputs
TRx3
OGU2
Pattern
Detection
Inputs
Trigger
Inputs
TRx2
Peripheral
Triggers
ERU_IOUT3
ERU_TOUT3
ERU_PDOUT3
ERU_IOUT2
ERU_TOUT2
ERU_PDOUT2
ERU_IOUT1
ERU_TOUT1
ERU_PDOUT1
ERU_IOUT0
ERU_TOUT0
ERU_PDOUT0
Peripheral
Triggers
Peripheral
Triggers
Peripheral
Triggers
ERU_GOUT0
ERU_GOUT1
ERU_GOUT2
ERU_GOUT3