XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-88
V2.1, 2008-08
SCU, V1.13
LEV2V
[11:8]
rw
Level Threshold 2 Voltage
This bit field defines the voltage level that is used as
check level threshold 2.
The values of the level thresholds are listed in the
data sheet.
L2OK
12
rh
Level Threshold 2 Check Result
0
B
The supply voltage is below the Level
Threshold 2 voltage LEV2V
1
B
The supply voltage is equal or above the Level
Threshold 2 voltage LEV2V
L2ACON
[14:13] rw
Level Threshold 2 Action Control
This bit field defines which actions are requested if
the supply voltage comparison matches the action
level L2ALEV. Following actions can be requested:
00
B
No action is requested
01
B
An interrupt is requested
10
B
A reset is requested
11
B
A reset and an interrupt are requested
L2ALEV
15
rw
Level Threshold 2 Action Level
0
B
When the supply voltage is below the Level
Threshold 2 voltage LEV2V the actions
configured by bit field L2ACON are requested
1
B
When the supply voltage is equal or above the
Level Threshold 2 voltage LEV2V the actions
configured by bit field L2ACON are requested
Field
Bits
Type
Description