XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-19
V2.1, 2008-08
SCU, V1.13
•
Bit PLLSTAT.VCOLOCK = 0, while the PLL is not locked
•
Bit SYSCON0.EMSVCO is set, if SYSCON0.EMCLKSELEN is set
•
The PLL VCO clock input is disconnected (PLLSTAT.FINDIS = 1) and the PLL clock
slows down to its VCO base frequency.
System Behavior
Emergency routines can be executed with the alternate clock (emergency clock or VCO
base frequency). The application can then enter a safe status and stop operation, or it
can switch to an emergency operating mode, where a reduced performance and/or
feature set is provided.
The Programmer’s Guide describes both, how to enable these features, and how to react
properly on each of the two events.