![Infineon Technologies XC2200 User Manual Download Page 441](http://html1.mh-extra.com/html/infineon-technologies/xc2200/xc2200_user-manual_2055439441.webp)
XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-181
V2.1, 2008-08
SCU, V1.13
LD
1
rw
Rebuild Level Detection for Status Flag for ETLx
This bit selects if the status flag FL is used as “sticky”
bit or if it rebuilds the result of a level detection.
0
B
The status flag FL is not cleared by hardware
and is used as “sticky” bit. Once set, it is not
influenced by any edge until it becomes
cleared by software.
1
B
The status flag FL rebuilds a level detection of
the desired event. It becomes automatically set
with a rising edge if RE = 1 or with a falling
edge if FE = 1. It becomes automatically
cleared with a rising edge if RE = 0 or with a
falling edge if FE = 0.
RE
2
rw
Rising Edge Detection Enable ETLx
This bit enables/disables the rising edge event as
edge event as set condition for the status flag FL or
as possible trigger pulse for TRxy.
0
B
A rising edge is not considered as edge event
1
B
A rising edge is considered as edge event
FE
3
rw
Falling Edge Detection Enable ETLx
This bit enables/disables the falling edge event as
edge event as set condition for the status flag FL or
as possible trigger pulse for TRxy.
0
B
A falling edge is not considered as edge event
1
B
A falling edge is considered as edge event
OCS
[6:4]
rw
Output Channel Select for ETLx Output Trigger
Pulse
This bit field defines which Output Channel OGUy is
targeted by an enabled trigger pulse TRxy.
000
B
Trigger pulses are sent to OGU0
001
B
Trigger pulses are sent to OGU1
010
B
Trigger pulses are sent to OGU2
011
B
Trigger pulses are sent to OGU3
1XX
B
Reserved, do not use this combination
FL
7
rwh
Status Flag for ETLx
This bit represents the status flag that becomes set
or cleared by the edge detection.
0
B
The enabled edge event has not been
detected
1
B
The enabled edge event has been detected
Field
Bits
Type
Description