![Infineon Technologies XC2200 User Manual Download Page 332](http://html1.mh-extra.com/html/infineon-technologies/xc2200/xc2200_user-manual_2055439332.webp)
XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-72
V2.1, 2008-08
SCU, V1.13
6.4.1.5
ESR as Trigger Input for the GSC
The ESR can be used to request a change in the Control Mode. For more information
see
.
6.4.1.6
Overlay with other Product Functions
Additionally other port inputs (e.g. serial communication input) can be used to generate
ESR operations.
This feature can be used for various applications:
•
Wake-up from a power saving mode on an external Interrupt or CCU6x trigger and
on a CAN or USIC operation
•
Wake-up from a Clock-off Mode on an external Interrupt or CCU6x trigger and on a
CAN or USIC operation
•
Request to enter a Clock-off Mode on an external Interrupt or CCU6x trigger and on
a CAN or USIC operation
•
Stop input for the CCU6x modules on an external event
For more information about the external interrupt trigger see
Table 6-6
Additional ESR0 Functions
Function
Module Function is Implemented
Trap Generation
Trap Generation
PSC Wake-up Request
OSC_WU enable
Power State Machine (PSC and CGU)
Peripheral Normal Mode Request Global Mode Control (GSC)
Table 6-7
Additional ESR1 Functions
Function
Module Function is Implemented
Trap Generation
Trap Generation
PSC Wake-up Request
OSC_WU enable
Power State Machine (PSC and CGU)
Peripheral Normal Mode Request Global Mode Control (GSC)