![Infineon Technologies XC2200 User Manual Download Page 645](http://html1.mh-extra.com/html/infineon-technologies/xc2200/xc2200_user-manual_2055439645.webp)
XC2200 Derivatives
System Units (Vol. 1 of 2)
Startup Configuration and Bootstrap Loading
User’s Manual
10-28
V2.1, 2008-08
SCFG/BSL, V1.3
10.6.4.1 Specific Settings
When the XC2200 has entered the CAN BSL mode, the following configuration is
automatically set:
Data frame
Identifier
Data message identifier DMSGID as sent by data
bytes [7:6] of the initialization frame
DLC = 8
Data length code, 8 bytes within CAN frame
Data bytes
0 to 7
Data bytes, assigned to increasing destination
(PSRAM) addresses
Table 10-13 CAN BSL-Specific State
Item
Value
Comments
P2_IOCR05
00A0
H
P2.5 is push/pull output (TxD)
P2_IOCR06
0020
H
P2.6 is input with pull-up (RxD)
SCU_HPOSCCON
0030
H
OSC_HP enabled, External Crystal/Clock mode
SCU_SYSCON0
0001
H
OSC_HP selected as system clock
CAN_MOCTR0L
0008
H
Message Object 0 Control, low
CAN_MOCTR0H
00A0
H
Message Object 0 Control, high
CAN_MOCTR1L
0000
H
Message Object 1 Control, low
CAN_MOCTR1H
0F28
H
Message Object 1 Control, high
CAN_MOFCR1H
0400
H
Message Object Function Control, high
CAN_MOAMR0H
1FFF
H
Message Object 0 - Acceptance Mask bit set
CAN_NPCR0
0003
H
Data input selection
Table 10-12 CAN Bootstrap Loader Frames
(cont’d)
Frame Type
Parameter
Description