![Infineon Technologies XC2200 User Manual Download Page 485](http://html1.mh-extra.com/html/infineon-technologies/xc2200/xc2200_user-manual_2055439485.webp)
XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-225
V2.1, 2008-08
SCU, V1.13
6.12.3.3 Register TRAPSET
This register contains the software set control for the trap status flags in register
TRAPSTAT. Clearing a bit in this register has no effect, reading a bit always returns zero.
TRAPSET
Trap Set Register
SFR (FE8C
H
/46
H
)
Reset Value: 0000
H
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
VCO
LCK
T
PE
T
RA
T
OSC
WDT
T
ESR
2
T
ESR
1
T
ESR
0
T
FA
T
r
w
w
w
w
w
w
w
w
Field
Bits
Type Description
FAT
0
w
Set Flash Access Trap Request Flag
0
B
No action
1
B
Flag TRAPSTAT.FAT is set
ESR0T
1
w
Set ESR0 Trap Request Flag
0
B
No action
1
B
Flag TRAPSTAT.ESR0T is set
ESR1T
2
w
Set ESR1 Trap Request Flag
0
B
No action
1
B
Flag TRAPSTAT.ESR1T is set
ESR2T
3
w
Set ESR2 Trap Request Flag
0
B
No action
1
B
Flag TRAPSTAT.ESR2T is set
OSCWDTT
4
w
Set OSCWDT Trap Request Flag
0
B
No action
1
B
Flag TRAPSTAT.OSCWDTT is set
RAT
5
w
Set Register Access Trap Request Flag
0
B
No action
1
B
Flag TRAPSTAT.RAT is set
PET
6
w
Set Parity Error Access Trap Request Flag
0
B
No action
1
B
Flag TRAPSTAT.PET is set
VCOLCKT
7
w
Set VCOLCK Trap Request Flag
0
B
No action
1
B
Flag TRAPSTAT.VCOLCKT is set