![Infineon Technologies XC2200 User Manual Download Page 401](http://html1.mh-extra.com/html/infineon-technologies/xc2200/xc2200_user-manual_2055439401.webp)
XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-141
V2.1, 2008-08
SCU, V1.13
L2INTEN
13
rw
Level Threshold 2 Interrupt Request Enable
This bit defines if an interrupt request trigger is
requested if the comparison check was successful.
When a check is successful is defined via bit
L2ALEV.
0
B
No interrupt is requested
1
B
An interrupt is requested
L2RSTEN
14
rw
Level Threshold 2 Reset Request Enable
This bit defines if a reset request trigger is requested
if the comparison check was successful. When a
check is successful is defined via bit L2ALEV.
0
B
No reset is requested
1
B
An reset is requested
L2ASEN
15
rw
Level Threshold 2 Asynchronous Action Enable
This bit defines if asynchronous action can be
performed if the comparison check was successful.
When a check is successful is defined via bit
L2ALEV.
0
B
No asynchronous actions are performed
1
B
Asynchronous actions can be performed
0
3, 11
rw
Reserved
Should be written with 0.
Field
Bits
Type
Description