XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-83
V2.1, 2008-08
SCU, V1.13
Power Supply and Control Functions
The power supply and control is divided into following parts:
•
monitoring of the supply voltage
•
controlling and adjusting the supply voltage
The supply voltage of pad IO domain for system and communication I/Os (power domain
DMP_B) is monitored by a Supply WatchDog (SWD, see
The core voltage for each of the two core supply domains is supervised by a separate
Power Validation Circuit (PVC) that provides two monitoring levels. Each monitoring
level can request an interrupt (e.g. power-fail warning) or a reset depending on the
voltage level. A PVC is used to detect under voltage due to an external short (see
).
By controlling the regulator, a core power domain can be switched off to save the
leakage current within this area (see
).
Table 6-10
XC2200 Power Domains Supply and Control
Power Domain
Supply
Source
Supply Voltage
[V]
Supply
Checked by
Pad IO domain
(DMP_B)
External supply V
DDPB
: 3.0
…
5.5 typ
See data sheet
SWD
ADC IO domain
(DMP_A)
External supply V
DDPA
: 3.0
…
5.5 typ
See data sheet
-
Wake-up domain
(DMP_M)
EVR_M
V
DDIM
: 1.0, 1.5 typ
See data sheet
PVC_M
System domain
(DMP_1)
EVR_1
V
DDI1
: 0, 1.0, 1.5 typ
See data sheet
PVC_1