![Infineon Technologies XC2200 User Manual Download Page 313](http://html1.mh-extra.com/html/infineon-technologies/xc2200/xc2200_user-manual_2055439313.webp)
XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-53
V2.1, 2008-08
SCU, V1.13
Example2
Reset request trigger A is asserted and leads to an Application Reset. Reset request
trigger A is de-asserted before RSTCNTA reached zero. Reset request trigger B is
asserted after reset request trigger A but before RSTCNTA reaches zero. Reset request
trigger B is also configured to result in a Application Reset. If the reset request trigger B
is de-asserted before RSTCNTA reached zero the Application Reset is de-asserted
when RSTCNTA reaches zero. If the reset request trigger B is de-asserted after
RSTCNTA reached zero the Application Reset is de-asserted when the reset request
trigger B is de-asserted.
6.3.3
Debug Reset Assertion
Unlike the other reset types a Debug Reset can only be asserted if the following two
conditions are valid:
•
A reset request trigger is asserted that request a debug reset
•
An Application Reset is already active in the system
6.3.4
Coupling of Reset Types
The different reset types are coupled for a better usage:
•
The assertion of a Power-on Reset automatically asserts also the following reset
types:
– Debug Reset
– Internal Application Reset
– Application Reset
•
The assertion of an Internal Application Reset automatically asserts also the
following reset type: