XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-35
V2.1, 2008-08
SCU, V1.13
EMFINDISEN
6
rw
Emergency Input Clock Disconnect Enable
This bit defines if bit PLLSTAT.FINDIS is set in a
VCOLCK emergency case.
0
B
No action
1
B
PLLSTAT.FINDIS is set in a VCOLCK
emergency case
Note: Please refer to the Programmer’s Guide for a
description of the proper handling.
PDIV
[11:8]
rw
P-Divider Value
The value the P-Divider operates is PDIV+1.
PACK
15
rw
P-Divider Ready Acknowledge
Setting this bit provides the acknowledge to PRDY.
0
4, 7,
[14:12]
r
Reserved
Read as 0; should be written with 0.
Field
Bits
Type
Description