![Infineon Technologies XC2200 User Manual Download Page 426](http://html1.mh-extra.com/html/infineon-technologies/xc2200/xc2200_user-manual_2055439426.webp)
XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-166
V2.1, 2008-08
SCU, V1.13
The following table describes the ERU input connections for the ERSx stages. The
selection is defined by the bit fields in register
.
Note: All functional inputs of the ERU are synchronized to f
SYS
before they can affect the
internal logic. The resulting delay of 2/f
SYS
and an uncertainty of 1/f
SYS
have to be
taken into account for precise timing calculation.
An edge of an input can only be correctly detected if both, the high phase and the
low phase of the input are each longer than 1/f
SYS
.
Table 6-14
ERSx Connections in
XC2200
Input
from/to
Module
I/O to
ERSx
Can be used to/as
ERS0 Inputs
ERU_0A0
P2.1
I
ERS0 input A
ERU_0A1
ESR1
I
ERU_0A2
U0C0_DX0INS
I
ERU_0A3
U0C0_DX2INS
I
ERU_0B0
P1.0
I
ERS0 input B
ERU_0B1
P5.13
I
ERU_0B2
U0C1_DX0INS
I
ERU_0B3
U0C1_DX2INS
I
ERS1 Inputs
ERU_1A0
P2.2
I
ERS1 input A
ERU_1A1
ESR2
I
ERU_1A2
U1C0_DX0INS
I
ERU_1A3
U1C0_DX2INS
I
ERU_1B0
P1.1
I
ERS1 input B
ERU_1B1
MultiCAN_CAN4INS
I
ERU_1B2
U1C1_DX0INS
I
ERU_1B3
U1C1_DX2INS
I
ERS2 Inputs
ERU_2A0
P1.2
I
ERS2 input A
ERU_2A1
MultiCAN_CAN3INS
I
ERU_2A2
U2C0_DX0INS
I
ERU_2A3
U2C0_DX2INS
I