![Infineon Technologies XC2200 User Manual Download Page 461](http://html1.mh-extra.com/html/infineon-technologies/xc2200/xc2200_user-manual_2055439461.webp)
XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-201
V2.1, 2008-08
SCU, V1.13
GSC
8
rh
GSC Interrupt Request Flag
This bit is set if a GSC trigger occurs and INTDIS.GSCI = 0.
0
B
No GSC interrupt was requested since this bit was
cleared the last time
1
B
A GSC interrupt was requested since this bit was
cleared the last time
ESR0T
11
rh
ESR0 Trap Request Flag
This bit is set if pin ESR0 is asserted.
0
B
No ESR0 trap was requested since this bit was cleared
the last time
1
B
An ESR0 trap was requested since this bit was cleared
the last time
ESR1T
12
rh
ESR1 Trap Request Flag
This bit is set if pin ESR1 is asserted.
0
B
No ESR1 trap was requested since this bit was cleared
the last time
1
B
An ESR1 trap was requested since this bit was cleared
the last time
ESR2T
13
rh
ESR2 Trap Request Flag
This bit is set if pin ESR2 is asserted.
0
B
No ESR2 trap was requested since this bit was cleared
the last time
1
B
An ESR2 trap was requested since this bit was cleared
the last time
RAT
15
rh
Register Access Trap Request Flag
This bit is set a protected register is written by an non-
authorized access.
0
B
No RA trap was requested since this bit was cleared the
last time
1
B
A RA trap was requested since this bit was cleared the
last time
0
[10:9],
14
r
Reserved
Read as 0; should be written with 0.
Field
Bits
Type Description