![Infineon Technologies XC2200 User Manual Download Page 489](http://html1.mh-extra.com/html/infineon-technologies/xc2200/xc2200_user-manual_2055439489.webp)
XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-229
V2.1, 2008-08
SCU, V1.13
6.12.3.5 Register TRAPNP
This register contains the control for the trap node pointers of all SCU trap request trigger
sources.
TRAPNP
Trap Node Pointer Register
SFR (FE92
H
/49
H
)
Reset Value: 8254
H
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
VCOLCK
PE
RA
OSCWDT
ESR2
ESR1
ESR0
FA
rw
rw
rw
rw
rw
rw
rw
rw
Field
Bits
Type Description
FA
[1:0]
rw
Trap Node Pointer for Flash Access Traps
TRAPNP.FA selects the trap request output for an
enabled FAT trap request.
00
B
Select request output SCU_TRQ0 (TFR.ACER)
01
B
Select request output SCU_TRQ1 (TFR.SR1)
10
B
Select request output SCU_TRQ2 (TFR.SR0)
11
B
Reserved, do not use this combination
ESR0
[3:2]
rw
Trap Node Pointer for ESR0 Traps
TRAPNP.ESR0 selects the trap request output for an
enabled ESR0 trap request.
00
B
Select request output SCU_TRQ0 (TFR.ACER)
01
B
Select request output SCU_TRQ1 (TFR.SR1)
10
B
Select request output SCU_TRQ2 (TFR.SR0)
11
B
Reserved, do not use this combination
ESR1
[5:4]
rw
Trap Node Pointer for ESR1 Traps
TRAPNP.ESR1 selects the trap request output for an
enabled ESR1 trap request.
00
B
Select request output SCU_TRQ0 (TFR.ACER)
01
B
Select request output SCU_TRQ1 (TFR.SR1)
10
B
Select request output SCU_TRQ2 (TFR.SR0)
11
B
Reserved, do not use this combination