XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-208
V2.1, 2008-08
SCU, V1.13
6.10.1
Temperature Compensation Registers
6.10.1.1 TCCR
This register contains the control options.
TCCR
Temperature Compensation Control Register
ESFR (F1AC
H
/D6
H
)
Reset Value: 0003
H
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
TCE
TCDIV
TCC
r
rw
rw
rw
Field
Bits
Type
Description
TCC
[1:0]
rw
Temperature Compensation Control
The value which controls the temperature
compensation inputs of the pads.
00
B
Maximum reduction = min. driver strength,
i.e. very low temperature
11
B
No reduction = max. driver strength,
i.e. very high temperature
TCDIV
[6:2]
rw
Temperature Compensation Clock Divider
This value adjusts the temperature compensation
logic to the selected operating frequency.
TCE
7
rw
Temperature Compensation Enable
0
B
No action
1
B
Enable counting to generate new temperature
values.
Clearing this bit also stops the temperature
compensation oscillator.
0
[15:8]
r
Reserved
Read as 0; should be written with 0.