![Infineon Technologies XC2200 User Manual Download Page 363](http://html1.mh-extra.com/html/infineon-technologies/xc2200/xc2200_user-manual_2055439363.webp)
XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-103
V2.1, 2008-08
SCU, V1.13
EVRMCON0
EVR_M Control 0 Register
ESFR (F084
H
/42
H
)
Reset Value: 0D20
H
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
EVR
DIS
0
CC
DIS
CCLEV
LPR
DIS
RES
1
0
LPRLEV
0
rh
r
rh
rw
rh
rw
rw
rw
r
Field
Bits
Type
Description
LPRLEV
[5:3]
rw
Low Power Reference Level
This bit field adjusts the core voltage generated by
the EVR for low power reference settings.
Do not change this value when writing to this register.
0
[7:6]
rw
Reserved
Must be written with reset value 00
B
.
RES1
8
rw
Reserved
Must be written with 1.
LPRDIS
9
rh
Low Power Reference Disable
0
B
The LPR is enabled
1
B
The LPR is disabled
This bit is updated by bit EVRMSETy.LPRDIS.
CCLEV
[11:10] rw
Current Control Level
The values for the different configurations are listed
in the data sheet.
CCDIS
12
rh
Current Control Disable
0
B
The current control is enabled
1
B
The current control is disabled
This bit is updated by bit EVRMSETy.CCDIS.
EVRDIS
15
rh
EVR_M Disable
0
B
The EVR_M is enabled
1
B
The EVR_M is disabled
This bit is updated by bit EVRMSETy.EVRDIS.
0
[2:0], 8
[14:13]
r
Reserved
Read as 0; should be written with 0.