XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-137
V2.1, 2008-08
SCU, V1.13
TRGSEL
[11:8]
rw
Trigger Selection
This bit field defines the which of the four possible OK
signals from both PVCs are used for validating the
power transition.
0000
B
Non of the signals is used
0001
B
OK 1 from PVC_M is used
0010
B
OK 2 from PVC_M is used
0011
B
OK 1 from PVC_M AND OK 2 from PVC_M is
used
0100
B
OK 1 from PVC_1 is used
0101
B
OK 1 from PVC_M AND OK 1 from PVC_1 is
used
0110
B
OK 2 from PVC_M AND OK 1 from PVC_1 is
used
0111
B
OK 1 from PVC_M AND OK 2 from PVC_M
AND OK 1 from PVC_1 is used
1000
B
OK 2 from PVC_1 is used
1001
B
OK 1 from PVC_M AND OK 2 from PVC_1 is
used
1010
B
OK 2 from PVC_M AND OK 2 from PVC_1 is
used
1011
B
OK 1 from PVC_M AND OK 2 from PVC_M
AND OK 2 from PVC_1 is used
1100
B
OK 1 from PVC_1 AND OK 2 from PVC_1 is
used
1101
B
OK 1 from PVC_M AND OK 1 from PVC_1
AND OK 2 from PVC_1 is used
1110
B
OK 2 from PVC_M AND OK 1 from PVC_1
AND OK2 from PVC_1 is used
1111
B
OK 1 from PVC_M AND OK 2 from PVC_M
AND OK 1 from PVC_1 AND OK2 from PVC_1
is used
SYSDIV
12
rw
System Clock Divider
This bit defines the number of system clock cycles
f
SYS
before the sequence is continued.
0
B
The sequence is continued after 1
f
SYS
cycles
1
B
The sequence is continued after 64
f
SYS
cycles
Field
Bits
Type
Description