![Infineon Technologies XC2200 User Manual Download Page 287](http://html1.mh-extra.com/html/infineon-technologies/xc2200/xc2200_user-manual_2055439287.webp)
XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-27
V2.1, 2008-08
SCU, V1.13
6.1.7.3
PLL Control Register
This register controls the trimmed current controlled clock source.
PLLOSCCON
PLL OSC Control Register
ESFR (F1B6
H
/DB
H
)
Reset Value: 0000
H
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
OSCTRIM
OSC
PD
r
rw
rw
Field
Bits
Type
Description
OSCPD
0
rw
Clock Source Power Saving Mode
0
B
Trimmed current controlled clock source is
active
1
B
Trimmed current controlled clock source is off
OSCTRIM
[9:1]
rw
Clock Source Trim Configuration
This value is used to adjust the frequency range of
the current controlled clock source.
Do not change this value when writing to this register.
0
[15:10] r
Reserved
Read as 0; should be written with 0.