XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-154
V2.1, 2008-08
SCU, V1.13
The mode that has to be entered when the Suspend Mode is requested.
The mode that has to be entered when the Suspend Mode is left.
The request to enter Suspend Mode is forwarded from the OCDS. When the Suspend
Mode is requested the system is expected to be stopped as soon as possible in an idle
state where no internal process is pending and in a way that this system state does not
lead to any damage internally or externally and can also be left without any damage.
Therefore all peripherals in the system are requested to enter a mode where the clock
can be stopped. This is done by sending a debug command.
Leaving the Suspend Mode should serve the goal that debugging is a non-intrusive
operation. Therefore leaving the Suspend Mode can not lead to only one dedicated
system mode, instead it leads to the system mode the system left when it was requested
to exit the Suspend Mode. The system mode is stored when a Suspend Mode request
is detected by the GSC and is used as target system mode when a leave Suspend Mode
trigger is detected by the GSC.
6.6.1.6
Error Feedback for a Mode Transition
In case at least one peripheral reports an error the error flag in register GSCSTAT is set.
If no error is currently detected upon a new assertion of a system mode by the GSC the
error flag is cleared. To inform the system of this erroneous state an interrupt can be
generated.