![Infineon Technologies XC2200 User Manual Download Page 375](http://html1.mh-extra.com/html/infineon-technologies/xc2200/xc2200_user-manual_2055439375.webp)
XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-115
V2.1, 2008-08
SCU, V1.13
6.5.7
Power Control Registers
6.5.7.1
PSC Status and Control Registers
SEQCON
Sequence Control Register
SFR (FEE4
H
/72
H
)
Reset Value: 8008
H
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
GSC
BY
SEQ
B
OSC
DIS
SEQ
A
OSC
DIS
0
ESR
2
EN
ESR
1
EN
ESR
0
EN
WUT
EN
0
IDLE
EN
SEQ
B
EN
SEQ
A
EN
SEQ
B
TRG
SEQ
A
TRG
rw
rw
rw
r
rw
rw
rw
rw
r
rw
rwh rwh
w
w
Field
Bits
Type
Description
SEQATRG
0
w
Sequence A Trigger
Setting this bit trigger a power transition defined by
sequence A
0
B
No action
1
B
Sequence A is started
Sequence A is only started if Sequence B is not
currently active.
SEQBTRG
1
w
Sequence B Trigger
Setting this bit trigger a power transition defined by
sequence B
0
B
No action
1
B
Sequence B is started
Sequence B is only started if Sequence A is not
currently active.
SEQAEN
2
rwh
Sequence A Enable
0
B
Sequence A is never started
1
B
Sequence A is started if requested
Sequence A is only started if Sequence B is not
currently active.
This bit is automatically cleared after the sequence
was started.