XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-174
V2.1, 2008-08
SCU, V1.13
6.8.6.2
Pattern Detection
The pattern detection logic allows the combination of the status flags of all ETLx units.
Each status flag can be individually included or excluded from the pattern detection for
each OGUy, via control bits EXOCONy.IPENx. The pattern detection block outputs the
following pattern detection results:
•
Pattern match
(EXOCONy.PDR = 1 and ERU_PDOUTy = 1):
A pattern match is indicated while all status flags FL that are included in the pattern
detection are 1.
•
Pattern miss
(EXOCONy.PDR = 0 and ERU_PDOUTy = 0):
A pattern miss is indicated while at least one of the status flags FL that are included
in the pattern detection is 0.
Table 6-15
OGUy Peripheral Trigger Connections in
XC2200
Input
from/to
Module
I/O to
OGUy
Can be used to/as
OGU0 Inputs
ERU_OGU01 CCU60_MCM_ST
I
Peripheral triggers for OGU0
ERU_OGU02 CCU60_T13_PM
I
ERU_OGU03 CC2_28
I
OGU1 Inputs
ERU_OGU11 CCU61_MCM_ST
I
Peripheral triggers for OGU1
ERU_OGU12 CCU61_T13_PM
I
ERU_OGU13 CC2_29
I
OGU2 Inputs
ERU_OGU21 CCU62_MCM_ST
I
Peripheral triggers for OGU2
ERU_OGU22 CCU62_T13_PM
I
ERU_OGU23 CC2_30
I
OGU3 Inputs
ERU_OGU31 CCU63_MCM_ST
I
Peripheral triggers for OGU3
ERU_OGU32 CCU63_T13_PM
I
ERU_OGU33 CC2_31
I