
201-901-003
Standalone Memory Test Failed
Explanation:
Memory Diagnostics Test Failed.
Severity:
Error
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Perform the actions mentioned one at a time and try the test after each action.
2.
If the problem remains, contact your technical-service representative.
3.
Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
4.
Make sure that DSA and BIOS/uEFI are at the latest level.
5.
Replace any DIMMS(s) mentioned in error, one by one.
6.
Make sure that all DIMMs are enabled in the Configuration/Setup Utility program.
7.
If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
Related Links:
v
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
DSA memory stress test results
The following messages can result when you run the memory stress test.
202-000-000
MemStr Test Passed
Explanation:
Test Passed.
Severity:
Event
Serviceable:
No
Recoverable:
No
Automatically notify Support:
No
Related Links:
v
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
201-901-003 • 202-000-000
944
System x3650 M5 Type 5462: Installation and Service Guide
Summary of Contents for System x3650 M5
Page 1: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Page 8: ...vi System x3650 M5 Type 5462 Installation and Service Guide ...
Page 16: ...xiv System x3650 M5 Type 5462 Installation and Service Guide ...
Page 58: ...42 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 86: ...70 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 320: ...304 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 832: ...816 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 988: ...972 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 992: ...976 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1001: ...Taiwan Class A compliance statement Notices 985 ...
Page 1002: ...986 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1008: ...992 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1009: ......
Page 1010: ... Part Number 00AK781 Printed in USA 1P P N 00AK781 ...