6.
▌2▐
Align the adapter with the PCI connector on the system board and press
the adapter firmly into the PCI connector on the system board.
7.
Rotate the retention bracket to the close position.
8.
Connect any required cables to the adapter.
Attention:
v
When you route cables, do not block any connectors or the ventilated space
around any of the fans.
v
Make sure that cables are not routed on top of components that are under
the riser-card assembly.
v
Make sure that cables are not pinched by the server components.
9.
Perform any configuration tasks that are required for the adapter.
10.
Reinstall the top cover (see “Replacing the top cover” on page 147).
11.
Slide the server into the rack.
12.
Reconnect the power cords and any cables that you removed.
13.
Turn on the peripheral devices and the server.
Expansion-slot covers
1
2
Adapters
Brackets
Adapter connector (slot 4)
Adapter connector (slot 5)
Figure 126. Adapter installation
196
System x3650 M5 Type 5462: Installation and Service Guide
Summary of Contents for System x3650 M5
Page 1: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Page 8: ...vi System x3650 M5 Type 5462 Installation and Service Guide ...
Page 16: ...xiv System x3650 M5 Type 5462 Installation and Service Guide ...
Page 58: ...42 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 86: ...70 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 320: ...304 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 832: ...816 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 988: ...972 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 992: ...976 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1001: ...Taiwan Class A compliance statement Notices 985 ...
Page 1002: ...986 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1008: ...992 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1009: ......
Page 1010: ... Part Number 00AK781 Printed in USA 1P P N 00AK781 ...