806f040c-2018ffff
[PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 24)
Explanation:
This message is for the use case when an implementation has detected that Memory has been
Disabled.
May also be shown as 806f040c2018ffff or 0x806f040c2018ffff
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0131
SNMP Trap ID:
Automatically notify Support:
No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit
reached), follow the suggested actions for that error event and restart the server.
3.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory
event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the
DIMM through the Setup utility or the Advanced Settings Utility (ASU).
806f040c-2581ffff
[PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (All DIMMS)
Explanation:
This message is for the use case when an implementation has detected that Memory has been
Disabled.
May also be shown as 806f040c2581ffff or 0x806f040c2581ffff
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0131
SNMP Trap ID:
Automatically notify Support:
No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit
reached), follow the suggested actions for that error event and restart the server.
3.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory
event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the
DIMM through the Setup utility or the Advanced Settings Utility (ASU). One of the DIMMs :
806f040c-2018ffff • 806f040c-2581ffff
532
System x3650 M5 Type 5462: Installation and Service Guide
Summary of Contents for System x3650 M5
Page 1: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Page 8: ...vi System x3650 M5 Type 5462 Installation and Service Guide ...
Page 16: ...xiv System x3650 M5 Type 5462 Installation and Service Guide ...
Page 58: ...42 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 86: ...70 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 320: ...304 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 832: ...816 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 988: ...972 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 992: ...976 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1001: ...Taiwan Class A compliance statement Notices 985 ...
Page 1002: ...986 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1008: ...992 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1009: ......
Page 1010: ... Part Number 00AK781 Printed in USA 1P P N 00AK781 ...