background image

40000024-00000000

Flash of [arg1] from [arg2] failed for user [arg3].

Explanation:

This message is for the use case where a user has not flashed the firmware component from the

interface and IP address due to a failure.

May also be shown as 4000002400000000 or 0x4000002400000000

Severity:

Info

Alert Category:

System - other

Serviceable:

No

CIM Information: Prefix:

IMM and

ID:

0036

SNMP Trap ID:

22

Automatically notify Support:

No

User response:

Information only; no action is required.

40000025-00000000

The [arg1] on system [arg2] is 75% full.

Explanation:

This message is for the use case where a Management Controller Event Log on a system is 75% full.

May also be shown as 4000002500000000 or 0x4000002500000000

Severity:

Info

Alert Category:

System - Event Log 75% full

Serviceable:

No

CIM Information: Prefix:

IMM and

ID:

0037

SNMP Trap ID:

35

Automatically notify Support:

No

User response:

Information only; no action is required.

40000026-00000000

The [arg1] on system [arg2] is 100% full.

Explanation:

This message is for the use case where a Management Controller Event Log on a system is 100% full.

May also be shown as 4000002600000000 or 0x4000002600000000

Severity:

Info

Alert Category:

System - Event Log 75% full

Serviceable:

No

CIM Information: Prefix:

IMM and

ID:

0038

SNMP Trap ID:

35

Automatically notify Support:

No

User response:

To avoid losing older log entries, save the log as a text file and clear the log.

40000024-00000000 • 40000026-00000000

330

System x3650 M5 Type 5462: Installation and Service Guide

Summary of Contents for System x3650 M5

Page 1: ...System x3650 M5 Type 5462 Installation and Service Guide ...

Page 2: ......

Page 3: ...System x3650 M5 Type 5462 Installation and Service Guide ...

Page 4: ...page 973 Notices on page 977 the Warranty Information document and the Safety Information and Environmental Notices and User Guide documents on the IBM Documentation CD First Edition October 2014 Copyright IBM Corporation 2014 US Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp ...

Page 5: ...he remote presence and blue screen capture features 57 Obtaining the IMM host name 58 Obtaining the IP address for the IMM 58 Logging on to the web interface 59 Using the embedded hypervisor 60 Configuring the Ethernet controller 61 Enabling Features on Demand Ethernet software 61 Enabling Features on Demand RAID software 61 Configuring RAID arrays 61 IBM Advanced Settings Utility program 62 Updat...

Page 6: ...ving a memory module 166 Installing a memory module 167 Removing the fan cage assembly 172 Replacing the fan cage assembly 173 Removing a hot swap fan 174 Replacing a hot swap fan 175 Removing the media cage 176 Replacing the media cage 178 Removing a riser card assembly 180 Replacing a riser card assembly 181 Removing the dedicated slotless RAID controller 183 Replacing the dedicated slotless RAI...

Page 7: ...ults 953 DSA system management test results 957 DSA tape drive test results 967 Appendix D Getting help and technical assistance 973 Before you call 973 Using the documentation 974 Getting help and information from the World Wide Web 974 How to send DSA data to IBM 974 Creating a personalized support web page 975 Software service and support 975 Hardware service and support 975 IBM Taiwan product ...

Page 8: ...vi System x3650 M5 Type 5462 Installation and Service Guide ...

Page 9: ...dukt Lees voordat u dit product installeert eerst de veiligheidsvoorschriften Ennen kuin asennat tämän tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de sécurité Vor der Installation dieses Produkts die Sicherheitshinweise lesen Prima di installare questo prodotto leggere le Informazioni sulla Sicurezza Copyright IBM Corp 2014 vii ...

Page 10: ...te produktet Antes de instalar este produto leia as Informações sobre Segurança Antes de instalar este producto lea la información de seguridad Läs säkerhetsinformationen innan du installerar den här produkten viii System x3650 M5 Type 5462 Installation and Service Guide ...

Page 11: ... or disconnect any cables or perform installation maintenance or reconfiguration of this product during an electrical storm v Connect all power cords to a properly wired and grounded electrical outlet v Connect to properly wired outlets any equipment that will be attached to this product v When possible use one hand only to connect or disconnect signal cables v Never turn on any equipment when the...

Page 12: ...e than 100 C 212 F v Repair or disassemble Dispose of the battery as required by local ordinances or regulations Statement 3 CAUTION When laser products such as CD ROMs DVD drives fiber optic devices or transmitters are installed note the following v Do not remove the covers Removing the covers of the laser product could result in exposure to hazardous laser radiation There are no serviceable part...

Page 13: ...Statement 4 CAUTION Use safe practices when lifting 18 kg 39 7 lb 32 kg 70 5 lb 55 kg 121 2 lb Statement 5 CAUTION The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove all electrical current from the device ensure that all power cords are disconnect...

Page 14: ...ver on a power supply or any part that has the following label attached Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serviceable parts inside these components If you suspect a problem with one of these parts contact a service technician Statement 12 CAUTION The following label indicates a hot surface nearby Statement 26 xii ...

Page 15: ... Safety Information Statement 2 DANGER v Always lower the leveling pads on the rack cabinet v Always install stabilizer brackets on the rack cabinet v Always install servers and optional devices starting from the bottom of the rack cabinet v Always install the heaviest devices in the bottom of the rack cabinet Safety xiii ...

Page 16: ...xiv System x3650 M5 Type 5462 Installation and Service Guide ...

Page 17: ... with the server The server contains IBM X Architecture technologies which help increase performance and reliability For more information see What your server offers on page 13 and Reliability availability and serviceability on page 17 You can obtain up to date information about the server and other IBM server products at http www ibm com systems x At http www ibm com support mysupport you can cre...

Page 18: ...pgrade the server to sixteen 2 5 inch simple swap hard disk drive bays Note The basic 2 5 inch simple swap model supports SATA simple swap hard disk drives only With the simple swap serveRAID function it supports SATA and SAS simple swap hard disk drives The following illustration shows a server with eight 2 5 inch hot swap hard disk drive bays You can purchase an optional kit to install the eight...

Page 19: ...e swap hard disk drives only With the simple swap serveRAID function it supports SATA and SAS simple swap hard disk drives The following illustration shows a server with eight 3 5 inch hot swap hard disk drive bays The following illustration shows a server with twelve 3 5 inch hot swap hard disk drive bays SATA SAS hard disk drive bays 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ...

Page 20: ...__________________ The model number and serial number are on the ID label on the front of the server as shown in the following illustration Note The illustrations in this document might differ slightly from your hardware In addition the system service label which is on the cover of the server provides a QR code for mobile access to service information You can scan the QR code using a QR code reade...

Page 21: ...x v 100 MHz microprocessor v 32 MB of RAM v Adobe Acrobat Reader 3 0 or later or xpdf which comes with Linux operating systems The IBM Documentation CD Use the Documentation Browser to browse the contents of the CD read brief descriptions of the documents and view documents using Adobe Acrobat Reader or xpdf The Documentation Browser automatically detects the regional settings in use in your serve...

Page 22: ...ion about using the Documentation Browser Related documentation This Installation and Service Guide contains general information about the server including how to set up and cable the server how to install supported optional devices how to configure the server and information to help you solve problems yourself and information for service technicians The following documentation also comes with the...

Page 23: ... that is not included in the server documentation These updates are available from the IBM website To check for updates go to http www ibm com supportportal Notices and statements in this document The caution and danger statements in this document are also in the multilingual Safety Information document which is on the IBM System x Documentation CD Each statement is numbered for reference to the c...

Page 24: ...ports depending on the model 4 GB 8 GB and 16 GB registered DIMMs 32 GB and 64 GB load reduction DIMM Integrated functions v Integrated management module 2 1 IMM2 1 which consolidates multiple management functions in a single chip v Broadcom BCM5719 Quad Port Gigabit Ethernet controller with Wake on LAN support v Eight Universal Serial Bus USB depending on the model Three front of the chassis Two ...

Page 25: ... Flash with optional FoD RAID 6 60 and SED upgrade RAID 5 50 4 GB Flash with optional FoD RAID 6 60 and SED upgrade FoD RAID 6 60 Upgrade FoD Zero Cache RAID 5 50 FoD Performance Accelerator FoD SSD Caching Enabler Video controller integrated into integrated management module 2 1 IMM2 1 v Matrox G200eR2 Note The maximum video resolution is 1600 x 1200 at 75 Hz SVGA compatible video controller DDR3...

Page 26: ...ss 3 0 x8 full height half length Electrical input v Sine wave input 50 60 Hz required v For 550W 750W 900W Platinum power supply Input voltage low range Minimum 100 Vac Maximum 127 Vac Input voltage high range Minimum 200 Vac Maximum 240 Vac v For 750W Titanium power supply Input voltage range Minimum 200 Vac Maximum 240 Vac v Input kilovolt amperes kVA approximately Minimum 0 168 kVA Maximum 1 1...

Page 27: ...es powerconfig html Acoustical noise emissions v Sound power idling 6 6 bels maximum v Sound power operating 6 6 bels maximum Heat output Approximate heat output v Minimum configuration 587 Btu per hour AC 172 watts v Maximum configuration 4063 Btu per hour AC 1191 watts Environment The IBM System x3650M5 compute node complies with ASHRAE class A3 specifications Power on v Temperature 5 C 40 C 41 ...

Page 28: ...ent in the data center All personnel and mobile furnishings and equipment must be connected to ground via an appropriate static control system The following items are considered the minimum requirements Conductive materials conductive flooring conductive footwear on all personnel that go into the datacenter all mobile furnishings and equipment will be made of conductive or static dissipative mater...

Page 29: ...ons on page 85 v Features on Demand If a Features on Demand feature is integrated in the server or in an optional device that is installed in the server you can purchase an activation key to activate the feature For information about Features on Demand see http www ibm com systems x fod v IBM ServerGuide Setup and Installation CD The ServerGuide Setup and Installation CD which you can download fro...

Page 30: ... the System Security menu option v Large data storage capacity and hot swap capability The hot swap server models support a maximum of twenty six 2 5 inch or fourteen 3 5 inch hot swap Serial Attached SCSI SAS hard disk drives or hot swap Serial ATA SATA hard disk drives The simple swap server models support a maximum of sixteen 2 5 inch or eight 3 5 inch simple swap SATA hard disk drives With the...

Page 31: ...ent wattages and different 80 plus efficiency level of power supplies in the server v ServeRAID support The ServeRAID adapter provides hardware redundant array of independent disks RAID support to create configurations The standard RAID adapter provides RAID levels 0 1 and 10 An optional RAID adapter is available for purchase v Systems management capabilities The server comes with an IMM2 1 When t...

Page 32: ... provides many of the core capabilities that are required for basic management which means instant out of the box business value The common tasks include the following v Discovery v Inventory v Configuration v System health v Monitoring v Updates v Event notification v Automation for managed systems The IBM Systems Director Web and command line interfaces provide a consistent interface that is foc...

Page 33: ...M in each rank is reserved as a space device v Diagnostic support for ServeRAID and Ethernet adapters v Error codes and messages v Error correcting code ECC L3 cache and system memory v Full Array Memory Mirroring FAMM redundancy v Hot swap cooling fans with speed sensing capability v Hot swap hard disk drives v Information and LCD system information display panel v Integrated Management Module IM...

Page 34: ...ible Firmware Interface UEFI v Solid state drives v Standby voltage for system management features and monitoring v Startup boot from LAN through remote initial program load RIPL or dynamic host configuration protocol boot protocol DHCP BOOTP v System auto configuring from the configuration menu v System error logging POST and IMM v Systems management monitoring through the Inter Integrated Circui...

Page 35: ...se latch CD DVD drive optical drive Bay 7 Bay 0 Video connector USB connectors User information tag Figure 10 8 hard disk drive configuration 16 hard disk drive configuration front view Hard disk drive activity LED green Hard disk drive status LED yellow Rack release latch USB connectors Operator information panel Rack release latch Video connector User information tag Figure 11 24 hard disk drive...

Page 36: ...ject button Press this button to release a DVD or CD from the optional DVD drive v Optional DVD drive activity LED When this LED is lit it indicates that the optional DVD drive is in use v Operator information panel This panel contains controls and LEDs that provide information about the status of the server For information about the controls and LEDs on the operator information panel see Operator...

Page 37: ...the server among other servers A system locator LED is also on the rear of the server This LED is used as a presence detection button as well You can use IBM Systems Director or IMM web interface to light this LED remotely This LED is controlled by the IMM The locator button is pressed to visually locate the server among the others servers v Check log LED When this yellow LED is lit it indicates t...

Page 38: ...illustration shows the controls on the LCD system information display panel v Scroll up button Press this button to scroll up or scroll to the left in the main menu to locate and select the system information that you want displayed v Select button Press this button to make your selection from the menu options v Scroll down button Press this button to scroll down or scroll to the right in the main...

Page 39: ...panel displays the number of errors that have occurred If no errors occur the no error menu will be available for navigation Error System VPD System FW Levels IMM Network Info System Environment Error 3 Error n MTM Serial UUID String uEFI Primary Level uEFI Backup Level IMM Primary Level IMM Primary Level pDSA Level IMM Hostname IMM Shared of Ext MAC IP Add DNS Primary DNS Secondary Ambient Temp C...

Page 40: ...evel IMM code level pDSA code level v IMM network information IMM hostname IMM dedicated MAC address Note Only the MAC address that is currently in use is displayed dedicated or shared IMM shared MAC address IP v4 information IP v6 address v System environmental information Ambient temperature CPU temperature AC input voltage Estimated power consumption Rear view The following illustration shows t...

Page 41: ...rk or a shared network See Using the Setup utility in the Problem Determination and Service Guide for more information v Ethernet connectors Use either of these connectors to connect the server to a network When you enable shared Ethernet for IMM2 1 in the Setup utility you can access the IMM2 1 using either the Ethernet 1 or the system management Ethernet default connector See Using the Setup uti...

Page 42: ...er is not present or the power supply or the LED itself has failed Flashing rapidly 4 times per second The server is turned off and is not ready to be turned on The power control button is disabled This will last approximately 5 to 10 seconds Flashing slowly once per second The server is turned off and is ready to be turned on You can press the power control button to turn on the server Lit The se...

Page 43: ...from your hardware Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 3 5 inch rear two hard disk drive kit Figure 22 PCI riser card adapter expansion slot locations Slot 4 Slot 5 3 5 inch rear two hard disk drive kit Slot 3 2 5 inch rear two hard disk drive kit Figure 23 PCI riser card adapter expansion slot locations Chapter 1 The System x3650 M5 server 27 ...

Page 44: ...kplate Fan cage Fan Air baffle cover PCI riser card assembly Heat sink Microprocessor DIMM System board 2 5 inch 4 drive filler panel Power supply filler panel Power supply 2 5 inch HDD hot swap backplane expander 2 5 inch HDD hot swap backplane 3 5 inch HDD hot swap backplane with 12 HDDs 3 5 inch HDD hot swap backplane with 8 HDDs 3 5 inch HDD simple swap backplate 3 5 inch simple swap hard disk...

Page 45: ...dle module connector Microprocessor 2 Fan 6 connector Fan 3 connector Fan 2 connector Fan 1 connector SAS SATA backplane power config connector 4 Front USB connector Front Video connector Microprocessor 1 DIMM connectors NMI button Battery SATA 0 SATA 1 PCI slot connector 4 PCI slot connector 5 Fan 4 connector Fan 5 connector Power supply connector SAS SATA backplane power config connector 3 SAS S...

Page 46: ... clear protective sticker on the top of the switch blocks you must remove and discard it to access the switches System management dedicated Video connector Ethernet 1 connector Ethernet 2 connector Ethernet 4 connector Ethernet 3 connector USB connectors Figure 26 System board external connectors 30 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 47: ...ndary backup server firmware ROM page Notes 1 If no jumper is present the server responds as if the pins are set to the default 2 Changing the position of the UEFI boot backup jumper J15 from pins 1 and 2 to pins 2 and 3 before the server is turned on alters which flash ROM page is loaded Do not change the jumper pin position after the server is turned on This can cause an unpredictable problem Th...

Page 48: ...nge any switch settings or move any jumpers turn off the server then disconnect all power cords and external cables Review the information in Safety on page vii Installation guidelines on page 283 Handling static sensitive devices on page 285 and Turning off the server on page 40 2 Any system board switch or jumper block that is not shown in the illustrations in this document are reserved The foll...

Page 49: ...IMM heartbeat LED Battery error LED DIMM 1 6 error LED Microprocessor 1 error LED Microprocessor 2 error LED System board LED Microprocessor mismatch LED DIMM 19 24 error LED Fan 1 error LED Fan 2 error LED Fan 3 error LED Fan 4 error LED Fan 5 error LED Fan 6 error LED Slot 4 error LED Slot 5 error LED DIMM 7 18 error LED SD adapter error LED Figure 28 System board LEDs PCI riser card assembly Sl...

Page 50: ...ser card assembly Slot 1 PCIe x8 Slot 3 ML2 Slot 2 PCIe x8 Figure 30 Type 2 PCI riser card PCI riser card assembly Slot 1 PCIe x16 Slot 3 PCIe x8 Figure 31 Type 3 PCI riser card PCI riser card assembly Slot 1 PCIe x16 Slot 3 ML2 Figure 32 Type 4 PCI riser card 34 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 51: ...while the server is connected to power PCI riser card assembly Slot 6 PCIe x8 Slot 8 PCIe x8 Slot 7 PCIe x8 Figure 33 Type 5 PCI riser card PCI riser card assembly Slot 6 PCIe x16 Slot 8 PCIe x8 Figure 34 Type 6 PCI riser card Upper PCI slot error LED Center PCI slot error LED Lower PCI slot error LED Figure 35 Riser card assembly LEDs Chapter 1 The System x3650 M5 server 35 ...

Page 52: ...te assemblies and backplanes v 2 5 inch simple swap hard disk drive backplate assembly Type 1 v 2 5 inch hot swap hard disk drive backplanes Type 2 Type 3 2 5 inch HDD simple swap backplate iPASS connector 2 5 inch HDD simple swap backplate for RAID card mini SAS HD connector Figure 36 Type 1 2 5 inch HDD hot swap backplane Figure 37 Type 2 36 System x3650 M5 Type 5462 Installation and Service Gui...

Page 53: ...v 3 5 inch simple swap hard disk drive backplate assembly Type 4 2 5 inch HDD hot swap backplane expander Figure 38 Type 3 Chapter 1 The System x3650 M5 server 37 ...

Page 54: ...disk drive backplanes Type 5 3 5 inch HDD simple swap backplate iPASS connector 3 5 inch HDD simple swap backplate for RAID card mini SAS HD connector Figure 39 Type 4 38 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 55: ... Type 6 3 5 inch HDD hot swap backplane with 8HDDs Figure 40 Type 5 3 5 inch HDD hot swap backplane with 12HDDs Figure 41 Type 6 Chapter 1 The System x3650 M5 server 39 ...

Page 56: ...tart automatically when power is restored v If your operating system supports the Wake on LAN feature the Wake on LAN feature can turn on the server Notes 1 When 4 GB or more of memory physical or logical is installed some memory is reserved for various system resources and is unavailable to the operating system The amount of memory that is reserved for system resources depends on the operating sy...

Page 57: ... off automatically v You can press the power control button to start an orderly shutdown of the operating system and turn off the server if your operating system supports this feature v If the operating system stops functioning you can press and hold the power control button for more than 4 seconds to turn off the server v The server can be turned off by Wake on LAN feature with the following limi...

Page 58: ...42 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 59: ...eXpress System Pack or UpdateXpress CD image An UpdateXpress System Pack contains an integration tested bundle of online firmware and device driver updates for your server Use UpdateXpress System Pack Installer to acquire and apply UpdateXpress System Packs and individual firmware and device driver updates For additional information and to download the UpdateXpress System Pack Installer go to the ...

Page 60: ...and installation tools that are designed for the server Use this CD during the installation of the server to configure basic hardware features such as an integrated SAS SATA controller with RAID capabilities and to simplify the installation of your operating system For information about using this CD see Using the ServerGuide Setup and Installation CD on page 46 v IBM FastSetup IBM FastSetup is a ...

Page 61: ...re to assist in determining the cause of the hang condition For more information see Using the remote presence and blue screen capture features on page 57 v Ethernet controller configuration For information about configuring the Ethernet controller see Configuring the Ethernet controller on page 61 v Features on Demand software Ethernet software The server provides Features on Demand software Ethe...

Page 62: ...he MegaRAID go to http www ibm com support entry portal docdisplay lndocid MIGR 5073015 Using the ServerGuide Setup and Installation CD Use this information as an overview for using the ServerGuide Setup and Installation CD The ServerGuide Setup and Installation CD provides software setup tools and installation tools that are designed for your server The ServerGuide program detects the server mode...

Page 63: ... not need setup diskettes You can use the CD to configure any supported IBM server model The setup program provides a list of tasks that are required to set up your server model On a server with a ServeRAID adapter or SAS SATA controller with RAID capabilities you can run the SAS SATA RAID configuration program to create logical drives Note Features and functions can vary slightly with different v...

Page 64: ... the following tasks v View configuration information v View and change assignments for devices and I O ports v Set the date and time v Set and change passwords v Set the startup characteristics of the server and the order of startup devices v Set and change settings for advanced hardware features v View set and change settings for power management features v View and clear error logs v Change int...

Page 65: ...mware the integrated management module and diagnostics code and the version and date This choice is on the full Setup utility menu only v System Settings Select this choice to view or change the server component settings Adapters and UEFI Drivers Select this choice to view information about the UEFI 1 10 and UEFI 2 0 compliant adapters and drivers installed in the server Processors Select this cho...

Page 66: ...ce Select this choice to enable or disable the Ethernet over USB interface on IMM The default is Enable Network Configuration Select this choice to view the system management network interface port the IMM MAC address the current IMM IP address and host name define the static IMM IP address subnet mask and gateway address specify whether to use the static IP address or have DHCP assign the IMM2 IP...

Page 67: ... the operating system supports Wake on LAN functions you can specify a startup sequence for the Wake on LAN functions For example you can define a startup sequence that checks for a disc in the CD RW DVD drive then checks the hard disk drive and then checks a network adapter This choice is on the full Setup utility menu only v Boot Manager Select this choice to view add delete or change the device...

Page 68: ...it limits access to the full Setup utility menu If an administrator password is set the full Setup utility menu is available only if you type the administrator password at the password prompt See Administrator password on page 55 for more information Clear Administrator Password Select this choice to clear an administrator password See Administrator password on page 55 for more information v Save ...

Page 69: ...user who types the power on password has access to only the limited Setup utility menu the user can set change and delete the power on password if the system administrator has given the user that authority Power on password If a power on password is set when you turn on the server you must type the power on password to complete the system startup You can use any combination of 6 20 printable ASCII...

Page 70: ...is turned off move power on password switch switch 2 on the system board switch block SW6 to the On position to enable the power on password override You can then start the Setup utility and reset the power on password You do not have to return the switch to the previous position The power on password override switch does not affect the administrator password 1 2 3 4 5 6 7 8 1 2 3 1 2 3 System TPM...

Page 71: ... Down arrow keys to select an item from the menu and press Enter Results The next time the server starts it returns to the startup sequence that is set in the Setup utility Starting the backup server firmware The system board contains a backup copy area for the server firmware This is a secondary copy of the server firmware that you update only during the process of updating the server firmware If...

Page 72: ...d the operating system watchdog timer times out The IMM might be configured to watch for the operating system watchdog timer and reboot the system after a timeout if the ASR feature is enabled Otherwise the IMM allows the administrator to generate a nonmaskable interrupt NMI by pressing an NMI button on the LCD system information display panel for an operating system memory dump ASR is supported b...

Page 73: ...application can access the SOL connection For more information about IMM see the Integrated Management Module II User s Guide at http www ibm com support entry portal docdisplay lndocid MIGR 5086346 Using the remote presence and blue screen capture features The remote presence and blue screen capture features are integrated functions of the integrated management module II IMM2 The remote presence ...

Page 74: ...E 5E AA D0 5 Convert the first pair of hexadecimal characters to binary for example 5 0101 C 1100 which results in 01011100 F3 FC FF FE 5E AA D0 6 Flip the 7th binary character from left 0 to 1 or 1 to 0 which results in 01011110 F3 FF FE 5E AA D0 7 Convert the binary back to hexadecimal for example 5E F3FCFFFE5EAAD0 Obtaining the IP address for the IMM Use this information to obtain the IP addres...

Page 75: ...the IMM for the first time you can obtain the user name and password from your system administrator All login attempts are documented in the system event log Note The IMM is set initially with a user name of USERID and password of PASSW0RD with a zero not a the letter O You have read write access You must change the default password the first time you log on 3 Click Log in to start the session The...

Page 76: ...F1 Setup is displayed press F1 3 From the Setup utility main menu select Boot Manager 4 Select Add Boot Option then select Generic Boot Option Embedded Hypervisor Press Enter and then select Esc 5 Select Change Boot Order Change the order Use the Up arrow and Down Arrow keys to select Embedded Hypervisor and use the plus and minus keys to move Embedded Hypervisor in the boot order When Embedded Hy...

Page 77: ...SI storage protocols that is integrated in the integrated management module For more information and instructions for activating the Features on Demand Ethernet software key see the IBM Features on Demand User s Guide To download the document go to http www ibm com systems x fod log in and click Help Enabling Features on Demand RAID software You can activate the Features on Demand FoD software upg...

Page 78: ...gure the optional remote presence features or other IMM2 settings The remote presence features provide enhanced systems management capabilities In addition the ASU program provides IMM LAN over USB interface configuration through the command line interface Use the command line interface to issue setup commands You can save any of the settings as a file and run the file as a script The ASU program ...

Page 79: ...4 Select the updates that you want to install and click Install to start the installation wizard Installing updates with your management server is not connected to the Internet About this task If your management server is not connected to the Internet to locate and install updates and interim fixes complete the following steps Procedure 1 Make sure that you have run the Discovery and Inventory col...

Page 80: ...d Settings Utility ASU e Scroll down and click the link and download the ASU version for your operating system 2 ASU sets the UUID in the Integrated Management Module IMM Select one of the following methods to access the Integrated Management Module IMM to set the UUID v Online from the target system LAN or keyboard console style KCS access v Remote access to the target system LAN based v Bootable...

Page 81: ... You do not need to specify a value for access_method when you use this access method Example asu set SYSTEM_PROD_DATA SysInfoUUID uuid_value The KCS access method uses the IPMI KCS interface This method requires that the IPMI driver be installed Some operating systems have the IPMI driver installed by default ASU provides the corresponding mapping layer See the Advanced Settings Utility Users Gui...

Page 82: ...e DMI SMBIOS data Use this information to update the DMI SMBIOS data About this task The Desktop Management Interface DMI must be updated when the system board is replaced Use the Advanced Settings Utility to update the DMI in the UEFI based server The ASU is an online tool that supports several operating systems Make sure that you download the version for your operating system You can download th...

Page 83: ...erver model number s n The serial number on the server Type sn zzzzzzz where zzzzzzz is the serial number asset_method The server asset tag number Type asset aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa where aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa is the asset tag number access_method The access method that you select to use from the following methods v Online authenticated LAN access type the command host imm_in...

Page 84: ...cedure might vary slightly from what is described in this document a Go to http www ibm com supportportal b Click the Downloads tab at the top of the panel c Under ToolsCenter select View ToolsCenter downloads d Select Advanced Settings Utility ASU e Scroll down and click the link and download the ASU version for your operating system Scroll down and look under Online Help to download the Advanced...

Page 85: ...rd asu set SYSTEM_PROD_DATA SysEncloseAssetTag asset_tag host imm_ip user imm_user_id password imm_password Examples that do use the userid and password default values asu set SYSTEM_PROD_DATA SysInfoProdName m t_model host imm_ip asu set SYSTEM_PROD_DATA SysInfoSerialNum s n host imm_ip asu set SYSTEM_PROD_DATA SysEncloseAssetTag asset_tag host imm_ip v Bootable media You can also build a bootabl...

Page 86: ...70 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 87: ...lem occurred If any hardware software or firmware was changed before the problem occurred if possible reverse those changes This might include any of the following items v Hardware components v Device drivers and firmware v System software v UEFI firmware v System input power or network connections 2 View the light path diagnostics LEDs and event logs The server is designed for ease of diagnosis o...

Page 88: ...gnostics For more information about UpdateXpress System Packs see http www ibm com support entry portal docdisplay lndocid SERV XPRESS and Updating the firmware on page 43 For more information about the Bootable Media Creator see http www ibm com support entry portal docdisplay lndocid TOOL BOMC Be sure to separately install any listed critical updates that have release dates that are later than t...

Page 89: ...roblems and suggested solutions To search for troubleshooting procedures and RETAIN tips go to http www ibm com supportportal 8 Use the troubleshooting tables See Troubleshooting by symptom on page 88 to find a solution to a problem that has identifiable symptoms A single problem might cause multiple symptoms Follow the troubleshooting procedure for the most obvious symptom If that procedure does ...

Page 90: ...ormation display panel indicate a microprocessor error the error might be in the microprocessor or in the microprocessor socket See Microprocessor problems on page 96 for information about diagnosing microprocessor problems v Before you run DSA you must determine whether the failing server is part of a shared hard disk drive cluster two or more servers sharing external storage devices If it is par...

Page 91: ...and power cords e Set all display controls to the middle positions f Turn on all external devices g Turn on the server If the server does not start see Troubleshooting by symptom on page 88 h Check the system error LED on the operator information panel If it is lit check the LCD system information display panel see LCD system information display panel on page 22 i Check for the following results v...

Page 92: ...rd interfaces Intelligent Platform Management Protocol IPMI version 2 0 Simple Network Management Protocol SNMP version 3 Common Information Model CIM Web browser For more information about the integrated management module II IMM2 see Using the integrated management module on page 56 Appendix A Integrated management module II IMM2 error messages on page 305 and the Integrated Management Module II ...

Page 93: ... collects and analyzes system information to aid in diagnosing server problems as well as offering a rich set of diagnostic tests of the major components of the server DSA Preboot collects the following information about the server Drive health information IMM2 configuration information IMM2 environmental information Event logs for ServeRAID controllers and service processors Installed hardware in...

Page 94: ... minimum configuration is required for the DC LED on the power supply to be lit v Power supply v Power cord Note You must turn on the server for the DC LED on the power supply to be lit The following illustration shows the locations of the power supply LEDs on the ac power supply The following table describes the problems that are indicated by various combinations of the power supply LEDs on an ac...

Page 95: ... Power supply not fully seated faulty system board or the power supply has failed 1 Reseat the power supply 2 Use the IBM Power Configurator utility to ensure current system power consumption is under limitation For more information and to download the utility go to http www ibm com systems bladecenter resources powerconfig html 3 Check the error LEDs on the system board and the IMM2 error message...

Page 96: ...ss 2 When this LED goes off momentarily this indicates that the IMM2 code has loaded completely 3 When this LED goes off momentarily and then starts blinking slowing approximately 1Hz this indicates that IMM2 is fully operational You can now press the power control button to power on the server 4 If this LED does not blink within 30 seconds of connecting a power source to the server trained techni...

Page 97: ...ge 305 Messages are listed on the left side of the screen and details about the selected message are displayed on the right side of the screen To move from one entry to the next use the Up Arrow and Down Arrow keys Some IMM sensors cause assertion events to be logged when their setpoints are reached When a setpoint condition no longer exists a corresponding deassertion event is logged However not ...

Page 98: ...port entry portal docdisplay lndocid SERV DSA If IPMItool is installed in the server you can use it to view the system event log Most recent versions of the Linux operating system come with a current version of IPMItool For an overview of IPMI go to http www ibm com developerworks linux blueprints and click Using Intelligent Platform Management Interface IPMI on IBM Linux platforms You can view th...

Page 99: ...g and no communication can be made with the IMM v If DSA Preboot is installed restart the server and press F2 to start DSA Preboot and view the event logs see Running the DSA Preboot diagnostic programs on page 86 for more information v Alternatively you can restart the server and press F1 to start the Setup utility and view the POST event log or system event log For more information see Viewing e...

Page 100: ... PCI and USB information v Installed applications and hot fixes available in DSA Portable only v Kernel modules available in DSA Portable only v Light path diagnostics status v Network interfaces and settings v Performance data and details about processes that are running v RAID controller configuration v Service processor integrated management module status and configuration v System configuratio...

Page 101: ...SB or PXE using the IBM ToolsCenter Bootable Media Creator BoMC For more details see the BoMC User Guide at http www ibm com support entry portal docdisplay lndocid TOOL BOMC In addition to the capabilities of the other editions of DSA DSA Preboot includes diagnostic routines that would be disruptive to run within the operating system environment such as resetting devices and causing loss of netwo...

Page 102: ...tand alone memory diagnostic environment you must restart the server to access the stand alone memory diagnostic environment again 5 Type gui to display the graphical user interface or type cmd to display the DSA interactive menu 6 Follow the instructions on the screen to select the diagnostic test to run Results If the diagnostic programs do not detect any hardware errors but the problem remains ...

Page 103: ... if you are running the DSA interactive menu or select Diagnostic Event Log in the graphical user interface To transfer DSA Preboot collections to an external USB device type the copy command in the DSA interactive menu Procedure v If you are running the DSA graphical user interface GUI click the Success link in the Status column v If you are running the DSA interactive menu CLI type x to exit the...

Page 104: ...olutions to problems that have identifiable symptoms About this task If you cannot find a solution to the problem in these tables see Appendix C DSA diagnostic test results on page 837 for information about testing the server and Running the DSA Preboot diagnostic programs on page 86 for additional information about running DSA Preboot program For additional information to help you solve problems ...

Page 105: ...is attached is enabled in the Setup utility v All cables and jumpers are installed correctly v The correct device driver is installed for the DVD drive 2 Run the DVD drive diagnostic programs 3 Reseat the following components a DVD drive b DVD drive cable 4 Replace the components listed in step 3 one at a time in the order shown restarting the server each time 5 Trained technician only Replace the...

Page 106: ...e Setup utility by pressing F1 1 See Nx boot failure on page 120 for more information 2 See Recovering the server firmware UEFI update failure on page 117 for more information Hard disk drive problems Use the troubleshooting tables to find solutions to problems that have identifiable symptoms v Follow the suggested actions in the order in which they are listed in the Action column until the proble...

Page 107: ...ane go to step 5 v If the green activity LED is flashing and the yellow status LED is lit replace the drive If the activity of the LEDs remains the same go to step 5 If the activity of the LEDs changes return to step 2 5 Make sure that the hard disk drive backplane is correctly seated When it is correctly seated the drive assemblies correctly connect to the backplane without bowing or causing move...

Page 108: ...d Reseat the hard disk drive e Turn on the server and observe the activity of the hard disk drive LEDs 2 See Problem determination tips on page 116 Hypervisor problems Use the troubleshooting tables to find solutions to problems that have identifiable symptoms v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved v If an action step i...

Page 109: ... POST watchdog setting make sure that sufficient time is allowed in the watchdog timeout value POST Watchdog Timer If the server continues to reset during POST see Appendix B UEFI POST diagnostic codes on page 817 and Appendix C DSA diagnostic test results on page 837 2 If neither condition applies check the system error log or IMM system event log see Event logs on page 81 Keyboard mouse or USB d...

Page 110: ...e or USB device does not work 1 Make sure that v The mouse or USB device cable is securely connected to the server v The mouse or USB device drivers are installed correctly v The server and the monitor are turned on v The mouse option is enabled in the Setup utility 2 If you are using a USB mouse or USB device and it is connected to a USB hub disconnect the mouse or USB device from the hub and con...

Page 111: ...y configuration in the Setup utility v All banks of memory are enabled The server might have automatically disabled a memory bank when it detected a problem or a memory bank might have been manually disabled v There is no memory mismatch when the server is at the minimum memory configuration 2 Reseat the DIMMs and then restart the server 3 Check the POST error log v If a DIMM was disabled by a sys...

Page 112: ... DIMM replace the failing DIMM 6 Trained technician only Install the failing DIMM into a DIMM connector for microprocessor 2 if installed to verify that the problem is not the microprocessor or the DIMM connector 7 Trained technician only Replace the system board Microprocessor problems Use the troubleshooting tables to find solutions to problems that have identifiable symptoms v Follow the sugges...

Page 113: ...een is blank 1 If the server is attached to a KVM switch bypass the KVM switch to eliminate it as a possible cause of the problem connect the monitor cable directly to the correct connector on the rear of the server 2 The IMM2 remote presence function is disabled if you install an optional video adapter To use the IMM2 remote presence function remove the optional video adapter 3 If the server inst...

Page 114: ...orrectly consider the location of the monitor Magnetic fields around other devices such as transformers appliances fluorescents and other monitors can cause screen jitter or wavy unreadable rolling or distorted screen images If this happens turn off the monitor Attention Moving a color monitor while it is turned on might cause screen discoloration Move the device and the monitor at least 305 mm 12...

Page 115: ... 10 seconds before restarting the server 4 If the problem still remains replace the dual port network adapter Log in failed by using LDAP account with SSL enabled 1 Make sure the license key is valid 2 Generate a new license key and log in again Optional device problems Use the troubleshooting tables to find solutions to problems that have identifiable symptoms v Follow the suggested actions in th...

Page 116: ...e connections for the device are secure 2 If the device comes with test instructions use those instructions to test the device 3 If the failing device is a SAS SATA device make sure that v The cables for all external SAS and SATA devices are connected correctly v The last device in each SAS and SATA chain or the end of the SAS and SATA cable is terminated correctly v Any external SAS and SATA devi...

Page 117: ... panel If the problem remains replace the operator information panel 2 Make sure that the reset button is working correctly a Disconnect the server power cords b Reconnect the power cords c Trained technician only Reseat the operator information panel cable and then repeat steps 2a and 2b v Trained technician only If the server starts replace the operator information panel v If the server does not...

Page 118: ... board on page 279 4 Reinstall the DIMM one at a time restarting the server each time If the Pwr rail B error has been recorded in the system event log again the DIMM that you just reinstalled is defective Replace the defective component The Pwr rail C error has been recorded in the system event log 1 Disconnect the server power cords 2 Trained technician only remove microprocessor 2 if Pwr rail C...

Page 119: ...ssembly 2 v Riser card assembly 2 3 Restart the server If the Pwr rail E error has been recorded in the system event log again trained technician only replace the system board see Removing the system board on page 276 and Replacing the system board on page 279 4 Reinstall the components one at a time in the order shown restarting the server each time If the Pwr rail E error has been recorded in th...

Page 120: ... v LCD monitor connected to rear VGA port if one is present 3 Restart the server If the Pwr rail F error has been recorded in the system event log again trained technician only replace the system board see Removing the system board on page 276 and Replacing the system board on page 279 4 Reinstall the components one at a time in the order shown restarting the server each time If the Pwr rail F err...

Page 121: ...restarting the server each time If the Pwr rail G error has been recorded in the system event log again the component that you just reinstalled is defective Replace the defective component v Microprocessor 2 Trained technician only Microprocessor 2 See Removing a microprocessor and heat sink on page 258 and Replacing a microprocessor and heat sink on page 264 v Riser card assembly 2 See Removing a...

Page 122: ... has been recorded in the system event log 1 Disconnect the server power cords 2 Remove the following components if the Pwr rail I error has been recorded in the system event log v Hard disk drives at backplane assembly 1 and or backplane assembly 2 v Hard disk drive backplane assembly 1 and or backplane assembly 2 3 Restart the server If the Pwr rail I error has been recorded in the system event ...

Page 123: ...in the component that you just reinstalled is defective Replace the defective component v Raid Card in Raid slot v Optional adapter if one is present installed in PCIe slot 5 v Optional adapter if one is present installed in PCIe slot 4 v Riser card assembly 1 or Rear two Hard disk drivekit on Riser 1 v Optional adapter if one is present installed in riser card assembly 1 or Rear Hard disk Drives ...

Page 124: ...ll the components one at a time in the order shown restarting the server each time If the Pwr rail M error has been recorded in the system event log again the component that you just reinstalled is defective Replace the defective component v Optional PCI adaptor power cable if one is present v PCI Riser Card Assembly where the optional PCI adaptor power cable correlated PCI adaptor is installed v ...

Page 125: ... b Serial cable 3 Replace the components listed in step 2 one at a time in the order shown restarting the server each time 4 Trained technician only Replace the system board ServerGuide problems Use the troubleshooting tables to find solutions to problems that have identifiable symptoms v Follow the suggested actions in the order in which they are listed in the Action column until the problem is s...

Page 126: ...or the ServerGuide System Partition is not present Run the ServerGuide program and make sure that setup is complete Software problems v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved v If an action step is preceded by Trained technician only that step must be performed only by a trained technician v Go to the IBM support website ...

Page 127: ...page 97 Solving power problems Power problems can be difficult to solve For example a short circuit can exist anywhere on any of the power distribution buses Usually a short circuit will cause the power subsystem to shut down because of an overcurrent condition About this task To diagnose a power problem use the following general procedure Procedure 1 Turn off the server and disconnect all power c...

Page 128: ...t installed in riser card assembly 2 v Riser card assembly 2 Pwr rail F error v Hard disk drives at backplane assembly 3 v Hard disk drive backplane assembly 3 v Rear Hard disk drives v Rear two Hard disk drive kit v Optional adapter if one is present installed in riser card assembly 1 v Riser card assembly 1 v PCIe Solid state drives v PCIe Solid state drive backplane assembly v USB devices v SD ...

Page 129: ...correlated PCI adaptor v PCI Riser Card Assembly where the optional PCI adaptor power cable correlated PCI adaptor is installed v Optional PCI adaptor power cable if one is present Pwr rail M error v Optional PCI adaptor power cable correlated PCI adaptor v PCI Riser Card Assembly where the optional PCI adaptor power cable correlated PCI adaptor is installed v Optional PCI adaptor power cable if o...

Page 130: ... speed and duplex mode of the hub v Check the Ethernet controller LEDs on the rear panel of the server These LEDs indicate whether there is a problem with the connector cable or hub The Ethernet link status LED is lit when the Ethernet controller receives a link pulse from the hub If the LED is off there might be a defective connector or cable or a problem with the hub The Ethernet transmit receiv...

Page 131: ...complete the following steps Procedure 1 Turn off the server 2 Make sure that the server is cabled correctly 3 Remove or disconnect the following devices one at a time until you find the failure Turn on the server and reconfigure it each time v Any external devices v Surge suppressor device on the server v Printer mouse and non IBM devices v Each adapter v Hard disk drives v Memory modules The min...

Page 132: ...e failure repeatable Has this configuration ever worked What changes if any were made before the configuration failed Is this the original reported failure v Diagnostic program type and version level v Hardware configuration print screen of the system summary v UEFI firmware level v IMM firmware level v Operating system software You can solve some problems by comparing the configuration and softwa...

Page 133: ...update package from one of the following sources v Download the server firmware update from the World Wide Web v Contact your IBM service representative To download the server firmware update package from the World Wide Web go to http www ibm com supportportal The flash memory of the server consists of a primary bank and a back up bank You must maintain a bootable UEFI firmware image in the back u...

Page 134: ...ge 147 13 Reconnect the power cord and any cables that you removed 14 Restart the server The system begins the power on self test POST If this does not recover the primary bank continue with the following steps 15 Remove the top cover see Removing the top cover on page 146 16 Reset the CMOS by removing the system battery see Removing the system battery on page 241 17 Leave the system battery out o...

Page 135: ...rimary bank The server boots from the primary bank Results Out of band method See the IMM2 documentation Integrated Management Module II User s Guide at http www ibm com support entry portal docdisplay lndocid MIGR 5086346 Automated boot recovery ABR Use this information for Automated boot recovery ABR About this task While the server is starting if the integrated management module II detects prob...

Page 136: ...cutive attempts automatic or manual the Nx boot failure feature causes the server to revert to the default UEFI configuration and start the Setup utility so that you can make the necessary corrections to the configuration and restart the server If the server is unable to successfully complete POST with the default configuration there might be a problem with the system board To specify the number o...

Page 137: ...of structural parts v Tier 1 customer replaceable unit CRU Replacement of Tier 1 CRUs is your responsibility If IBM installs a Tier 1 CRU at your request you will be charged for the installation v Tier 2 customer replaceable unit You may install a Tier 2 CRU yourself or request IBM to install it at no additional charge under the type of warranty service that is designated for your server For infor...

Page 138: ...rt numbers for the server replaceable components 30 31 32 33 35 3 4 5 6 7 21 9 8 29 28 27 26 25 22 23 24 20 18 17 11 12 2 1 19 34 13 16 15 14 10 Figure 47 Server components 122 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 139: ...AE688 5 Microprocessor Intel Xeon E5 2650 v3 2 3 GHz 25 MB 2133 MHz 105 W 10 core 00AE686 5 Microprocessor Intel Xeon E5 2699 v3 2 3 GHz 45 MB 2133 MHz 145 W 18 core 00KC789 5 Microprocessor Intel Xeon E5 2670 v3 2 3 GHz 30 MB 2133 MHz 120 W 12 core 00AE684 5 Microprocessor Intel Xeon E5 2680 v3 2 5 GHz 30 MB 2133 MHz 120 W 12 core 00AE683 5 Microprocessor Intel Xeon E5 2690 v3 2 6 GHz 30 MB 2133 ...

Page 140: ...ch hot swap 1 2 TB SAS 10 K 46W6819 20 Solid state drive 2 5 inch hot swap SATA 480 GB 00AJ406 20 Solid state drive 2 5 inch hot swap SAS 800 GB 00AJ218 20 Solid state drive 2 5 inch hot swap SATA 960 GB 00FN348 20 Solid state drive 2 5 inch hot swap SAS 1 6 TB 00AJ223 21 2 5 inch 4 drive filler panel 00KF417 22 Hard disk drive 3 5 inch simple swap 2 TB SATA 7 2 K 00FN119 22 Hard disk drive 3 5 in...

Page 141: ...ule 00FK636 3 5 inch simple swap filler 69Y5368 Media cage filler 00KF416 Blank fan filler 00KF418 Brocade 8Gb FC single port HBA 46M6061 Brocade 8Gb FC dual port HBA 46M6062 Brocade 16Gb FC Single port HBA 81Y1671 Brocade 16Gb FC Dual port HBA 81Y1678 Emulex 8Gb FC single port HBA 42D0491 Emulex 8Gb FC dual port HBA 42D0500 Emulex 16Gb FC single port HBA 00D8546 Emulex 16Gb FC dual port HBA 00D85...

Page 142: ...r 42C1816 BNT SFP transceiver module assembly 46C3449 ServeRAID M5200 Series 1GB Cache RAID 5 Upgrade 47C8657 ServeRAID M5200 Series 1GB Flash RAID 5 Upgrade 47C8661 ServeRAID M5200 Series 2GB Flash RAID 5 Upgrade 47C8665 ServeRAID M5200 Series 4GB Flash RAID 5 Upgrade 47C8669 Qlogic 8200 Dual Port 10GbE SFP VFA 90Y4605 Cable UMIQ V2 00AK143 Cable COM PORT 00KC965 Cable FPC PLANAR 00FK803 Cable SA...

Page 143: ...SB 1M 44E8893 Cable 1ft USB for USB kit 44E8894 Cable super cap for ServRAID M5200 series flash 46C9793 Cable USB CRUs 46M6475 Cable USB CRUs 46M6477 Cable internal USB FRU 81Y3643 Line cord 2 8M 39M5377 Line cord 2 8M 39M5509 Power cord 00JY023 Keyboard US ENG 00FL300 UltraSlim enhanced SATA multi burner 00FL353 Adapter assembly 43W8496 32GB Enterprise Value USB Memory Key 00ML201 3 0 VOLT batter...

Page 144: ...ase from the retail store Table 9 Structural parts Type 5462 Index Description Part number Chassis 2 5 inch HDD model 00KF407 Chassis 3 5 inch 8 HDD model 00KF408 Chassis 3 5 inch 12 HDD model 00KF409 35 Top cover 2 5 inch model and 3 5 inch 8 HDD model 00KF404 35 Top cover 3 5 inch 12 HDD model 00KF405 To order a structural part complete the following steps Note Changes are made periodically to t...

Page 145: ...umber Used in these countries and regions 39M5206 China 39M5102 Australia Fiji Kiribati Nauru New Zealand Papua New Guinea 39M5123 Afghanistan Albania Algeria Andorra Angola Armenia Austria Azerbaijan Belarus Belgium Benin Bosnia and Herzegovina Bulgaria Burkina Faso Burundi Cambodia Cameroon Cape Verde Central African Republic Chad Comoros Congo Democratic Republic of Congo Republic of Cote D Ivo...

Page 146: ...Bolivia Caicos Islands Canada Cayman Islands Colombia Costa Rica Cuba Dominican Republic Ecuador El Salvador Guam Guatemala Haiti Honduras Jamaica Mexico Micronesia Federal States of Netherlands Antilles Nicaragua Panama Peru Philippines Saudi Arabia Thailand Taiwan United States of America Venezuela 39M5081 110 120 V Antigua and Barbuda Aruba Bahamas Barbados Belize Bermuda Bolivia Caicos Islands...

Page 147: ...ge 121 to determine whether a component is a structural part Tier 1 CRU or Tier 2 CRU For information about the terms of the warranty see the Warranty Information document that comes with the server For more information about getting service and assistance see Appendix D Getting help and technical assistance on page 973 Returning a device or component If you are instructed to return a device or co...

Page 148: ...deo cables The following illustration shows the internal routing and connectors for the video graphic adapter VGA power cables Video graphic adapters VGA power cables Video card power connector 2 Video card power connector 1 Figure 48 VGA power cables connection 132 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 149: ...e 8x2 5 inch drive model cables The following illustration shows the internal routing for the 8x2 5 inch drive model cables 8x2 5 inch simple swap hard disk drive model v 8x2 5 inch simple swap hard disk drive with hardware RAID v 8x2 5 inch simple swap hard disk drive with software RAID SAS signal cable Power configuration cable Figure 49 8x2 5 inch simple swap hard disk drive with hardware RAID ...

Page 150: ...gnal cable Power configuration cable Figure 50 8x2 5 inch simple swap hard disk drive with software RAID cabling 2 5 inch HDD hot swap backplane Power configuration cable SAS signal cable SAS 0 SAS 1 Figure 51 Cable connection 134 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 151: ...e internal routing for the 16x2 5 inch drive model cables 16x2 5 inch simple swap hard disk drive model v 16x2 5 inch simple swap hard disk drive with hardware RAID SAS signal cable Power configuration cable SAS 0 SAS 1 Figure 52 8x2 5 inch hot swap hard disk drive cabling Chapter 5 Removing and replacing components 135 ...

Page 152: ...e 53 16x2 5 inch simple swap hard disk drive with hardware RAID cabling 2 5 inch HDD hot swap backplane Power configuration cable SAS signal cable SAS 0 SAS 1 2 5 inch HDD hot swap backplane Power configuration cable SAS signal cable SAS 0 SAS 1 Figure 54 16x2 5 inch hot swap hard disk drive cabling 136 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 153: ...S 0 SAS 1 Figure 55 16x2 5 inch hot swap hard disk drive cabling 2 5 inch HDD hot swap backplane Power configuration cable SAS signal cable Power configuration cable 2 5 inch HDD hot swap backplane expander Figure 56 16x2 5 inch hot swap hard disk drive cable connection Chapter 5 Removing and replacing components 137 ...

Page 154: ...ng for the 24x2 5 inch drive model cables 24x2 5 inch hot swap hard disk drive model v 24x2 5 inch hot swap hard disk drive with 3 identical backplanes SAS signal cables Power configuration cables SAS 0 SAS 1 SAS 1 SAS 0 Figure 57 16x2 5 inch hot swap hard disk drive cabling 138 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 155: ...signal cable SAS 0 SAS 1 2 5 inch HDD hot swap backplane Power configuration cable SAS signal cable SAS 0 SAS 1 Figure 58 24x2 5 inch hot swap hard disk drive cabling SAS signal cables Power configuration cables SAS 0 SAS 1 SAS 0 SAS 1 SAS 0 SAS 1 Figure 59 24x2 5 inch hot swap hard disk drive cabling Chapter 5 Removing and replacing components 139 ...

Page 156: ... hot swap backplane expander 2 5 inch HDD hot swap backplane Power configuration cable SAS signal cable SAS signal cable Figure 60 24x2 5 inch hot swap hard disk drive cabling SAS signal cables Power configuration cables SAS 0 SAS 1 SAS 0 SAS 1 SAS 1 SAS 0 Figure 61 24x2 5 inch hot swap hard disk drive cabling 140 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 157: ...le 2 5 inch HDD hot swap backplane expander Power configuration cable 2 5 inch HDD hot swap backplane expander SAS signal cable Figure 62 24x2 5 inch hot swap hard disk drive cable connection SAS signal cable Y cable Power configuration cables SAS 0 SAS 1 Figure 63 24x2 5 inch hot swap hard disk drive cabling Chapter 5 Removing and replacing components 141 ...

Page 158: ... inch drive model cables The following illustration shows the internal routing for the 8x3 5 inch drive model cables 8x3 5 inch simple swap hard disk drive model v 8x3 5 inch simple swap hard disk drive with hardware RAID v 8x3 5 inch simple swap hard disk drive with software RAID SAS signal cable Power configuration cable Figure 64 8x3 5 inch simple swap hard disk drives with hardware RAID cablin...

Page 159: ...d disk drive model v 8x3 5 inch hot swap hard disk drive SAS signal cable Power configuration cable Figure 65 8x3 5 inch simple swap hard disk drives with software RAID cabling Chapter 5 Removing and replacing components 143 ...

Page 160: ...ws the internal routing for the 12x3 5 inch drive model cables 12x3 5 inch hot swap hard disk drive model v 12x3 5 inch hot swap hard disk drive SAS signal cable Power configuration cable SAS 0 SAS 1 Figure 66 8x3 5 inch hot swap hard disk drives cabling 144 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 161: ...ement of structural parts is your responsibility If IBM installs a structural part at your request you will be charged for the installation The illustrations in this document might differ slightly from your hardware SAS signal cable Power configuration cables SAS 0 SAS 1 Figure 67 12x3 5 inch hot swap hard disk drive cabling Chapter 5 Removing and replacing components 145 ...

Page 162: ...ress down on the left and right side latches and slide the server out of the rack enclosure until both slide rails lock 4 1 Push the cover release latch back 2 then lift it up Slide the cover back and 3 then lift off the server Set the cover aside Attention For proper cooling and airflow replace the server cover before you turn on the server 5 If you are instructed to return the top cover follow a...

Page 163: ... slide the top cover forward make sure that all the tabs and the pins on the top and side of the top cover engage the chassis correctly 2 Place the cover release latch in the open up position 3 Position the top cover on top of the server 4 Insert the bottom tabs of the top cover into the matching slots in the server chassis 5 Press down on the cover release latch to slide the cover forward and loc...

Page 164: ...page Safety on page vii and Installation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables see Turning off the server on page 40 3 Remove the top cover see Removing the top cover on page 146 4 Remove PCI riser card assemblies if needed see Removing a riser card assembly 5 Disconnect the RAID adapter battery flash power module...

Page 165: ...ernal cables 3 Remove the top cover see Removing the top cover on page 146 4 Align the air baffle tabs with the baffle slots on both sides of the chassis then lower the air baffle into the server Press the air baffle down until it is securely seated Note Close the retaining clip on each end of the DIMM connector before installing the air baffle for proper cooling 5 Replace PCI riser card assemblie...

Page 166: ...nect all power cords and external cables 3 Remove the top cover see Removing the top cover on page 146 4 Remove the power supplies See Removing a power supply on page 228 5 Grasp the handle and pull the power paddle module up 6 If you are instructed to return the power paddle module follow all packaging instructions and use any packaging materials for shipping that are supplied to you Power paddle...

Page 167: ...top cover see Removing the top cover on page 146 4 Grasp the handle and align the power paddle module with the connector on the system board Push the power paddle module to the system board and make sure it is firmly seated 5 Replacing the power supplies See Replacing a power supply on page 229 6 Replacing the top cover see Replacing the top cover on page 147 7 Slide the server into the rack 8 Rec...

Page 168: ...are instructed to return the front USB assembly follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing the front USB assembly Use this information to replace the front USB assembly About this task To install the front USB assembly complete the following steps Procedure 1 Read the safety information that begins on Safety on page vii and Ins...

Page 169: ... cable on the system board press evenly on the cable Pressing on one side of the cable might cause damage to the cable or connector 6 Replace the top cover see Replacing the top cover on page 147 Front USB assembly Figure 75 Front USB assembly installation Front USB cable Front USB connector Figure 76 Front USB assembly cable routing Chapter 5 Removing and replacing components 153 ...

Page 170: ...ou make changes to disk drives disk drive controllers including controllers that are integrated on the system board disk drive backplanes or disk drive cables back up all important data that is stored on hard disks v Before you remove any component of a RAID array back up all RAID configuration information To remove a hot swap hard disk drive complete the following steps Procedure 1 Read the safet...

Page 171: ...les and other equipment that are specified in the documentation that comes with the drive v Select the bay in which you want to install the drive v Check the instructions that come with the drive to determine whether you have to set any switches or jumpers on the drive If you are installing a SAS or SATA hard disk drive be sure to set the SAS or SATA ID for that device v The hot swap server models...

Page 172: ...nlocked position b Align the drive with the guide rails in the bay c Gently push the drive into the bay until the drive stops d Rotate the tray handle to the closed locked position e Check the hard disk drive status LED to verify that the hard disk drive is operating correctly If the yellow hard disk drive status LED of a drive is lit continuously that drive is faulty and must be replaced If the g...

Page 173: ... SATA hard disk drive complete the following steps Attention v To avoid damage to the hard disk drive connectors make sure that the server cover is in place and fully closed whenever you install or remove a hard disk drive v To make sure that there is adequate system cooling do not operate the server for more than 2 minutes without either a hard disk drive or a filler panel installed in each bay P...

Page 174: ...comes with the drive v Select the bay in which you want to install the drive v Check the instructions that come with the drive to determine whether you have to set any switches or jumpers on the drive If you are installing a SATA device be sure to set the SATA ID for that device v The simple swap server models support up to sixteen 2 5 inch or eight 3 5 inch simple swap SATA hard disk drives Do no...

Page 175: ...e and place it on a static protective surface 5 Install the hard disk drive in the drive bay Align the drive assembly with the guide rails in the bay and gently push the drive into the bay until the drive stops 6 Reinstall the drive bay filler panel that you removed earlier if needed 7 If you are installing additional simple swap hard disk drives do so now 8 Turn on the peripheral devices and the ...

Page 176: ...fan cage assembly see Removing the fan cage assembly on page 172 5 Pull the connector toward the front of the server to remove the optical drive cable from the connector on the system board 6 From the rear of the optical drive cage 1 press and hold the connector latch on the left of the cable connector At the same time 2 grasp the cable connector and slide it to the right Remove the optical drive ...

Page 177: ...lation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables 3 Remove the top cover see Removing the top cover on page 146 4 Remove the fan cage assembly see Removing the fan cage assembly on page 172 5 Align the cable connector with the slot on the rear of the optical drive cage 1 Press and hold the connector latch then 2 push t...

Page 178: ...e assembly see Replacing the fan cage assembly on page 173 7 Replace the top cover see Replacing the top cover on page 147 8 Slide the server into the rack 9 Reconnect the power cords and any cables that you removed 10 Turn on the peripheral devices and the server Cable connector latch Figure 87 Optical drive cable latch 1 DVD drive cable Cable connector latch Optical drive connector 2 Figure 88 O...

Page 179: ...ve the server top cover see Removing the top cover on page 146 4 1 Press and hold the release tab to the right as you 2 push the drive from the rear to slide it out of the bay 5 Slide the drive retention clip from the side of the drive Save the clip to use when you install the replacement drive or replace the optical drive filler panel 6 Attach the drive retention clip to the side of the optical d...

Page 180: ...ive To install an optional optical drive complete the following steps Procedure 1 Read the safety information that begins on Safety on page vii and Installation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables Note When you disconnect the power source from the server you lose the ability to view the LEDs because the LEDs are...

Page 181: ...ents and avoid direct exposure to the beam Class 1 Laser Product Laser Klasse 1 Laser Klass 1 Luokan 1 Laserlaite Appareil A Laser de Classe 1 6 Touch the static protective package that contains the new optical drive to any unpainted metal surface on the server then remove the optical drive from the package and place it on a static protective surface 7 Follow the instructions that come with the dr...

Page 182: ...that begins on Safety on page vii and Installation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect all power cords 3 Remove the top cover see Removing the top cover on page 146 4 Remove the air baffle see Removing the air baffle on page 148 5 Carefully open the retaining clips on each end of the DIMM connector and remove the DIMM Attention To avoid breaking the r...

Page 183: ...000 registered or load deduction synchronous dynamic random access memory SDRAM dual inline memory modules DIMMs with error correcting code ECC See http www ibm com systems info x86servers serverproven compat us for a list of supported memory modules for the server The specifications of a DDR4 DIMM are on a label on the DIMM in the following format ggggg eRxff PC4v wwwwwm aa bb ccd where ggggg is ...

Page 184: ... fastest common frequency Do not install registered and load reduction DIMMs in the same server v The following rules apply to DDR4 RDIMM speed as it relates to the number of LRDIMMs in a channel When you install 1 LRDIMM per channel the memory runs at 2133MHz When you install 2 LRDIMMs per channel the memory runs at 2133 MHz When you install 3 LRDIMMs per channel the memory runs at 1600 MHz v The...

Page 185: ...m performance install a minimum of four DIMMs for each microprocessor v DIMMs in the server must be the same type RDIMM or LRDIMM to ensure that the server will operate correctly Notes 1 You can install DIMMs for microprocessor 2 as soon as you install microprocessor 2 you do not have to wait until all of the DIMM slots for microprocessor 1 are filled 2 DIMM slots 13 24 are reserved for microproce...

Page 186: ...el or 2DPC two DIMM per channel memory configuration are recommended Unless there is a need for memory capacity over memory frequency 3DPC three DIMMs per channel configuration is not recommended since 3DPC configuration forces the memory subsystem to run at a lower frequency 1600 MHz Please refer to the Understanding and Optimizing Memory Performance for Intel Xeon Processor E5 2600 v3 Series in ...

Page 187: ...n both ends of the DIMM simultaneously The retaining clips snap into the locked position when the DIMM is firmly seated in the connector Note If there is a gap between the DIMM and the retaining clips the DIMM has not been correctly inserted open the retaining clips remove the DIMM and then reinsert it 10 Reconnect the power cords and any cables that you removed 11 Replace the air baffle see Repla...

Page 188: ...stallation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables 3 Remove the top cover see Removing the top cover on page 146 4 1 Lift the fan cage assembly release latches and rotate the release latches up until the fan cage assembly disengages from the chassis 2 then lift the fan cage assembly out of the server 5 If you are in...

Page 189: ...ith the slots on both sides of the chassis and lower it into the server 5 2 Rotate the fan cage assembly release latches down until the release latches are in the locked position and make sure the assembly is correctly seated into place 6 Replace the fans if needed see Replacing a hot swap fan on page 175 7 Replace the top cover see Replacing the top cover on page 147 8 Slide the server into the r...

Page 190: ...ling dual motor hot swap fan will be lit Attention To ensure proper system cooling do not remove the top cover for more than 30 minutes during this procedure 3 1 Pull the fan latch to the left to release the fan from the fan connector and 2 pull the fan out of the fan cage Attention To ensure proper operation replace a failed hot swap fan within 30 seconds 4 If you are instructed to return the fan...

Page 191: ...static protective package that contains the new fan to any unpainted metal surface on the server Then remove the new fan from the package 4 Orient the fan over the fan slot in the fan cage so that the fan connector aligns with the connector on the system board 5 Insert the fan into the fan slot in the fan cage and press it down until it is seated correctly in the slot Note Make sure that the newly...

Page 192: ...rds and all external cables if necessary 3 Remove the top cover see Removing the top cover on page 146 4 Disconnect the front USB DVD drive and operator information panel LCD panel cables from the system board Please remember the relevant cable routing Note To disconnect the operator information LCD panel cable press evenly on the connector first then pull the cable out Operator information LCD pa...

Page 193: ...t of the server and set it aside 7 If you are instructed to return the media cage follow all of the packaging instructions and use any packaging materials for shipping that are supplied to you Thumbscrew Figure 101 Thumbscrew Media cage Figure 102 Media cage removal Chapter 5 Removing and replacing components 177 ...

Page 194: ... 3 Remove the top cover see Removing the top cover on page 146 4 Carefully slide the media cage into the server 5 Tighten the thumbscrew to secure the media cage onto the server 6 Reconnect the USB CD DVD and operator information LCD panel cables to the system board first then route the cables as the following illustration Remember to insert the cables into the cable clip for proper routing Media ...

Page 195: ...he server into the rack 9 Reconnect the power cords and any cables that you removed 10 Turn on the peripheral devices and the server Operator information LCD panel cable DVD drive cable Front USB cable Figure 105 Cable routing Chapter 5 Removing and replacing components 179 ...

Page 196: ... off the server and peripheral devices and disconnect the power cord and all external cables 3 Remove the top cover see Removing the top cover on page 146 4 Grasp the blue touch points on the front and the rear side of the riser card assembly then lift it up to remove it from the server Place the riser card assembly on a flat static protective surface v For half length and low profile adapters v F...

Page 197: ...iser slot 2 the closest slot to the power supplies You must install a riser card assembly in slot 2 with microprocessor 2 v PCI riser card brackets must be installed even if you do not install an adapter To install a riser card assembly complete the following steps Procedure 1 Read the safety information that begins on Safety on page vii and Installation guidelines on page 283 2 Turn off the serve...

Page 198: ... lower it into the server and press down firmly until the riser card assembly is seated correctly in the connector on the system board v For half length and low profile adapters v For full height full length adapters Note Shipping brackets are only included in the server that is pre configured with full height full length adapters PCI riser card assembly 2 PCI riser card assembly 1 Figure 108 Rise...

Page 199: ...ation of the connectors To remove the dedicated slotless RAID controller complete the following steps Procedure 1 Read the safety information that begins on Safety on page vii and Installation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessary 3 Remove the top cover see Removing the top cover on page 146 4 Disconn...

Page 200: ...ty information that begins on Safety on page vii and Installation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessary 3 Remove the top cover see Removing the top cover on page 146 4 If you are installing a new or replacement controller touch the static protective package that contains the new controller to any unpa...

Page 201: ...n adapter in a riser card assembly Use this information to remove an adapter About this task This topic describes removing an adapter from a expansion slot in a riser card assembly These instructions apply to PCI adapters such as video graphic adapters and network adapters The following illustration shows the locations of the adapter expansion slots from the rear of the server Dedicated slotless R...

Page 202: ...re 1 Read the safety information that begins on Safety on page vii and Installation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect all power cords then remove the top cover see Removing the top cover on page 146 3 Press down on the left and right side latches and slide the server out of the rack enclosure until both slide rails lock then remove the top cover see...

Page 203: ...cket then 2 rotate it to the open position 8 Remove the screws if present These screws can be fastened to the side of the riser card assembly for storage if needed 9 Carefully grasp the adapter by its top edge or upper corners and pull the adapter from the PCI expansion slot 10 If you are instructed to return the adapter follow all packaging instructions and use any packaging materials for shippin...

Page 204: ...d slide the server out of the rack enclosure until both slide rails lock then remove the top cover see Removing the top cover on page 146 4 Disconnect any cables from the adapter make note of the cable routing in case you reinstall the adapter later 5 Rotate the bracket to the open position 6 Remove the screws if present 7 Carefully grasp the adapter by its top edge or upper corners and pull the a...

Page 205: ...the rear two hard disk drive kit on page 200 v If you are removing an adapter from PCI expansion slot 3 remove rear two hard disk drive kit 1 v If you are removing an adapter from PCI expansion slot 8 remove rear two hard disk drive kit 2 5 Disconnect any cables from the adapter make note of the cable routing in case you reinstall the adapter later 6 1 Slide the retention bracket then 2 rotate it ...

Page 206: ...y Slot number The maximal card dimension supported Riser card assembly 1 1 Full height up to full length 2 Full height up to full length 3 Full height half length 4 Low profile 5 Low profile Slot 1 Slot 2 Slot 3 Slot 6 Slot 7 Slot 8 Slot 4 Slot 5 Figure 119 PCI riser card adapter expansion slot locations Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 3 5 inch rear two hard disk drive kit Figure 120 PCI riser ...

Page 207: ... http www ibm com supportportal v Do not set the maximum digital video adapter resolution above 1600 x 1200 at 75 Hz for an LCD monitor This is the highest resolution that is supported for any add on video adapter that you install in the server v Read the following table before installing memory modules when any Quadro adapters is installed Table 14 NVIDIA Quadro video adapter configurations Descr...

Page 208: ... or the NVIDIA Tesla Kxx adapter options in systems containing 1TB of system memory or more If these options are installed in systems with 1TB of memory or more it might cause undetected data corruption and system instability These options are only supported in systems containing less than 1TB of memory For more information see RETAIN tip H213010 at http www ibm com support entry myportal docdispl...

Page 209: ... riser card assembly v Make sure that cables are not pinched by the server components 11 Align the riser card assembly with the selected PCI connector on the system board and align it with the slots on the chassis then lower it into the server and press down firmly until the riser card assembly is seated correctly in the connector on the system board v For half length and low profile adapters 1 3 ...

Page 210: ...cluded in the server that is pre configured with full height full length adapters PCI riser card assembly 2 PCI riser card assembly 1 Figure 124 Riser card assembly installation half length and low profile adapters 194 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 211: ... an adapter complete the following steps Procedure 1 Read the safety information that begins on Safety on page vii and Installation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables 3 Remove the server top cover see Removing the top cover on page 146 4 1 Rotate the bracket to the open position 5 Slide the expansion slot cover...

Page 212: ...top of components that are under the riser card assembly v Make sure that cables are not pinched by the server components 9 Perform any configuration tasks that are required for the adapter 10 Reinstall the top cover see Replacing the top cover on page 147 11 Slide the server into the rack 12 Reconnect the power cords and any cables that you removed 13 Turn on the peripheral devices and the server...

Page 213: ...pter firmly into the slot on the rear two hard disk drive kit 8 Connect any required cables to the adapter Attention v When you route cables do not block any connectors or the ventilated space around any of the fans v Make sure that cables are not routed on top of components under the rear two hard disk drive kit v Make sure that cables are not pinched by the server components 9 Perform any config...

Page 214: ...ttery flash power module cable from the RAID adapter battery flash power module connector 5 If the flash power modules are located behind the full height full length adapters you need to remove the riser card assemblies first See Removing an adapter in a riser card assembly on page 185 6 1 Press the release tab and 2 grasp the battery flash power module out of the holder 7 If you are instructed to...

Page 215: ... the top cover on page 146 4 Install the ServeRAID adapter on the system board see Replacing an adapter on page 190 or install the ServeRAID adapter on the riser card and install the riser card assembly in the server see Replacing an adapter on page 190 5 If the flash power modules are located behind the full height full length adapters remove the two shipping brackets first 6 Align the battery fl...

Page 216: ...nd turn on the server and peripheral devices Removing the rear two hard disk drive kit Use this information to remove the rear two hard disk drive kit About this task See http www ibm com systems info x86servers serverproven compat us for a list of hard disk drives that you can use with the server To remove the rear two hard disk drive kit complete the following steps Procedure 1 Read the safety i...

Page 217: ... hard disk drive kit removal 2 5 inch rear two hard disk drive kit 1 Figure 131 2 5 inch rear two hard disk drive kit removal 3 5 inch rear two hard disk drive kit Figure 132 3 5 inch rear two hard disk drive kit removal Chapter 5 Removing and replacing components 201 ...

Page 218: ...ear two hard disk drive kit complete the following steps Procedure 1 Read the safety information that begins on Safety on page vii and Installation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect all power cords 3 Remove the top cover see Removing the top cover on page 146 4 Align the rear two hard disk drive kit with the connector on the system board and align i...

Page 219: ...drive kit there are two possible cable routing configurations Connect to the RAID card on the slot 5 from the rear hard drive backplane 3 5 inch rear two hard disk drive kit Figure 134 3 5 inch rear two hard disk drive kit installation 2 5 inch rear hard disk drive kit Raid adapter Mini SAS HD cable SAS 0 Figure 135 2 5 inch rear two hard disk drive kit cable routing Chapter 5 Removing and replaci...

Page 220: ...p backplane with 12 HDDs from the rear hard drive backplane SAS signal cable 3 5 hard disk drive cage Raid adapter Figure 136 3 5 inch rear two hard disk drive kit cable routing 204 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 221: ... Replacing the top cover on page 147 8 Slide the server into the rack 9 Reconnect the power cords and any cables that you removed 10 Turn on the peripheral devices and the server SAS signal cable 3 5 hard disk drive cage Figure 137 3 5 inch rear two hard disk drive kit cable routing Chapter 5 Removing and replacing components 205 ...

Page 222: ...6 4 Remove the fan cage assembly see Removing the fan cage assembly on page 172 5 Disconnect the front USB operator information panel cables form the connector mounted on the chassis side Note Disengage all latches release tabs or locks on cable connectors when you disconnect all cables from the system board Failing to release them before removing the cables will damage the cable sockets on the sy...

Page 223: ...ove it from the server 8 Grasp the EIA assembly and pull it slightly forward to remove it from the server Screws Figure 139 Screw removal Cable arm cover Figure 140 Cable cover removal Chapter 5 Removing and replacing components 207 ...

Page 224: ...ion that begins on Safety on page vii and Installation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect the power cord and all external cables 3 Remove the cover see Removing the top cover on page 146 4 Remove the fan cage assembly see Removing the fan cage assembly on page 172 5 Disconnect the front video cable from the system board EIA assembly Figure 141 EIA as...

Page 225: ...age the cable sockets on the system board The cable sockets on the system board are fragile Any damage to the cable sockets may require replacing the system board 6 Loosen screws and remove them 7 Tilt the cable cover and remove it from the server Front video cable Figure 143 Front video cable removal Screws Figure 144 Screw removal Chapter 5 Removing and replacing components 209 ...

Page 226: ...e instructed to return the EIA assembly follow all packaging instructions and use any packaging materials for shipping that are supplied to you Cable arm cover Figure 145 Cable cover removal EIA assembly Figure 146 EIA assembly removal 210 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 227: ... on page 172 5 Disconnect the front USB operator information panel cables from the connector mounted on the chassis side wall Note Disengage all latches release tabs or locks on cable connectors when you disconnect all cables from the system board Failing to release them before removing the cables will damage the cable sockets on the system board The cable sockets on the system board are fragile A...

Page 228: ...e it from the server 8 Grasp the EIA assembly and pull it slightly forward to remove it from the server 9 Position the EIA assembly as shown in the following illustration then remove the assembly out of the server 1 2 Cable arm cover Figure 149 Cable cover removal EIA assembly Figure 150 EIA assembly removal 212 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 229: ...er see Removing the top cover on page 146 4 Remove the fan cage assembly see Removing the fan cage assembly on page 172 5 Disconnect the front video cable form the system board Note Disengage all latches release tabs or locks on cable connectors when you disconnect all cables from the system board Failing to release them before removing the cables will damage the cable sockets on the system board ...

Page 230: ... and remove them 7 Tilt the cable cover and remove it from the server Front video cable Figure 152 Front video cable removal Screws Figure 153 Screw removal 214 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 231: ...are instructed to return the EIA assembly follow all packaging instructions and use any packaging materials for shipping that are supplied to you Cable arm cover Figure 154 Cable cover removal EIA assembly Figure 155 EIA assembly removal Chapter 5 Removing and replacing components 215 ...

Page 232: ... on Safety on page vii and Installation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect the power cord and all external cables 3 Remove the top cover see Removing the top cover on page 146 4 Remove the fan cage see Removing the fan cage assembly on page 172 5 Insert the cable connector into the cable connector holder 6 Align the EIA assembly with the alignment pi...

Page 233: ...ar of the server to fix the EIA assembly on the server 8 Tilt and install the cable cover EIA assembly Alignment pin Figure 157 EIA assembly alignment EIA assembly Figure 158 EIA assembly installation Chapter 5 Removing and replacing components 217 ...

Page 234: ...system board and the connector mounted on the chassis side wall Cable arm cover Figure 159 Cable cover installation Screws Figure 160 Screw installation Front USB operator information panel cable Figure 161 Cable connection 218 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 235: ...ins on Safety on page vii and Installation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect the power cord and all external cables 3 Remove the top cover see Removing the top cover on page 146 4 Remove the fan cage assembly see Removing the fan cage assembly on page 172 5 Route the cable into the slot 6 Align the EIA assembly with the alignment pin and push it sli...

Page 236: ...install the cable cover 8 Fasten screws Alignment pin EIA assembly Figure 163 EIA assembly alignment Cable arm cover Figure 164 Cable cover installation 220 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 237: ... Replace the top cover see Replacing the top cover on page 147 12 Slide the server into the rack 13 Reconnect the power cords and any cables that you removed 14 Turn on the peripheral devices and the server Screws Figure 165 Screw installation Front video cable Figure 166 Cable connection Chapter 5 Removing and replacing components 221 ...

Page 238: ...e 283 2 Turn off the server and peripheral devices and disconnect the power cord and all external cables 3 Remove the cover see Removing the top cover on page 146 4 Remove the fan cage see Removing the fan cage assembly on page 172 5 Insert the cable connector into the cable connector holder 6 Align the EIA assembly with the alignment pin EIA assembly Figure 167 Cable connector installation 222 Sy...

Page 239: ...n the server 8 Angle the cable cover as shown in the following illustration and slide the cable arm towards the front of the server EIA assembly Alignment pin Figure 168 EIA assembly alignment EIA assembly Figure 169 EIA assembly installation Chapter 5 Removing and replacing components 223 ...

Page 240: ...stem board and the connector mounted on the chassis side wall 1 2 Cable arm cover Figure 170 Cable cover installation Screws Figure 171 Screw installation Front USB operator information panel cable Figure 172 Cable connection 224 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 241: ...s on Safety on page vii and Installation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect the power cord and all external cables 3 Remove the top cover see Removing the top cover on page 146 4 Remove the fan cage assembly see Removing the fan cage assembly on page 172 5 Route the cable into the slot 6 Align the EIA assembly with the alignment pin and push it sligh...

Page 242: ...install the cable cover 8 Fasten screws Alignment pin EIA assembly Figure 174 EIA assembly alignment Cable arm cover Figure 175 Cable cover installation 226 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 243: ... Replace the top cover see Replacing the top cover on page 147 12 Slide the server into the rack 13 Reconnect the power cords and any cables that you removed 14 Turn on the peripheral devices and the server Screws Figure 176 Screw installation Front video cable Figure 177 Cable connection Chapter 5 Removing and replacing components 227 ...

Page 244: ...that all power cords are disconnected from the power source 1 2 Statement 8 CAUTION Never remove the cover on a power supply or any part that has the following label attached Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serviceable parts inside these components If you suspect a problem with one of these parts contact a servi...

Page 245: ... wattage you may use the IBM Power Configurator utility to determine current system power consumption For more information and to download the utility go to http www ibm com systems bladecenter resources powerconfig html v The server comes with one hot swap 12 volt output power supply that connects to power supply bay 1 The input voltage is 100 127 V ac or 200 240 V ac auto sensing v Power supplie...

Page 246: ... remove the cover on a power supply or any part that has the following label attached Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serviceable parts inside these components If you suspect a problem with one of these parts contact a service technician To install a power supply complete the following steps Procedure 1 Read the...

Page 247: ...k of the server 6 Route the power cord through the cable hook and loop on the rear of the server to prevent the power cord from being accidentally pulled out when you slide the server in and out of the rack 7 Connect the other end of the power cord to a properly grounded electrical outlet 8 Make sure that the ac power LED and the dc power LED on the ac power supply are lit indicating that the powe...

Page 248: ...ds and all external cables if necessary 3 Remove the top cover see Removing the top cover on page 146 4 Pull the hard disk drives or fillers out of the server slightly to disengage them from the backplate assembly backplane See Removing a hot swap hard disk drive on page 154and Removing a simple swap hard disk drive on page 157 for details 5 To obtain more working room remove the fan cage assembly...

Page 249: ...the 2 5 inch simple swap backplate assembly hot swap hard disk drive backplane About this task To install the 2 5 inch simple swap backplate assembly hot swap hard disk drive backplane complete the following steps Procedure 1 Read the safety information that begins on Safety on page vii and Installation guidelines on page 283 2 Turn off the server and disconnect all power cords and external cables...

Page 250: ...and power configuration cables to the backplate assembly backplane and the system board See 2 5 inch hard disk drive cable connection for details 8 Replace the fan cage and fans if you removed them see Replacing the fan cage assembly on page 173 and Replacing a hot swap fan on page 175 9 Reinstall the hard disk drives see Replacing a hot swap hard disk drive on page 155 10 Install the top cover se...

Page 251: ...y backplane See Removing a hot swap hard disk drive on page 154and Removing a simple swap hard disk drive on page 157 for details 5 To obtain more working room remove the fan cage assembly see Removing the fan cage assembly on page 172 6 Disconnect the SAS signal and power configuration cables from the system board Note Disengage all latches release tabs or locks on cable connectors when you disco...

Page 252: ...ou are instructed to return the hard disk drive backplate assembly backplane follow all packaging instructions and use any packaging materials for shipping that are supplied to you 1 3 2 Figure 183 3 5 inch simple swap backplate assembly hot swap hard disk drive backplane removal 1 2 3 Figure 184 3 5 inch hot swap hard disk drive backplane removal 236 System x3650 M5 Type 5462 Installation and Ser...

Page 253: ...he backplate assembly backplane See Removing a hot swap hard disk drive on page 154and Removing a simple swap hard disk drive on page 157 for details 5 Remove the fan cage assembly see Removing the fan cage assembly on page 172 6 1 Insert the backplate assembly backplane tabs into slots on the bottom of the drive cage at an angle then 2 rotate the backplate assembly backplane toward the front the ...

Page 254: ... the fan cage assembly and fans if you removed them see Replacing the fan cage assembly on page 173 and Replacing a hot swap fan on page 175 11 Install the top cover see Replacing the top cover on page 147 12 Slide the server into the rack 13 Reconnect the power cords and any cables that you removed 3 2 1 Figure 185 Eight 3 5 inch simple swap backplate assembly hot swap hard disk drive backplane 3...

Page 255: ...nd peripheral devices and disconnect the power cords 3 Remove the top cover see Removing the top cover on page 146 4 Remove the flash device a Unlock the retention latch on the USB connector by pushing down the blue locking collar b Grasp the flash device and pull to remove it from the connector 5 If you are instructed to return the flash device follow all packaging instructions and use any packag...

Page 256: ... the riser card assembly see Removing a riser card assembly on page 180 5 Install the flash device a Align the flash device with the connector on the system board and push it into the USB connector until it is firmly seated b Pull up the blue locking collar to lock the flash device into the USB connector 6 Reconnect the power cords and any cables that you removed 7 Replace the top cover see Replac...

Page 257: ...pport center or business partner Note After you replace the battery you must reconfigure the server and reset the system date and time Statement 2 CAUTION When replacing the lithium battery use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer If your system has a module containing a lithium battery replace it only with the same module type made by the same...

Page 258: ...battery from the socket Attention Do not lift the battery by using excessive force Failing to remove the battery properly may damage the socket on the system board Any damage to the socket may require replacing the system board 6 Dispose of the battery as required by local ordinances or regulations See the IBM Environmental Notices and User s Guide on the IBM Documentation CD for more information ...

Page 259: ...r If your system has a module containing a lithium battery replace it only with the same module type made by the same manufacturer The battery contains lithium and can explode if not properly used handled or disposed of Do not v Throw or immerse into water v Heat to more than 100 C 212 F v Repair or disassemble Dispose of the battery as required by local ordinances or regulations To install the re...

Page 260: ...Reinstall the riser card assembly 2 see Replacing a riser card assembly on page 181 if necessary 8 Install the top cover see Replacing the top cover on page 147 9 Slide the server into the rack 10 Reconnect the external cables then reconnect the power cords and turn on the peripheral devices and the server 11 Start the Setup utility and reset the configuration v Set the system date and time v Set ...

Page 261: ...ords and all external cables if necessary 3 Remove the top cover see Removing the top cover on page 146 4 Remove the fan cage assembly See Removing the fan cage assembly on page 172 5 Pull up the release latch slightly and slide the LCD panel assembly out of the server 6 Disconnect the cable from the back of the LCD system information display panel Note To disconnect the cable press evenly on the ...

Page 262: ...nect the power cords and all external cables if necessary 3 Remove the top cover see Removing the top cover on page 146 4 Remove the fan cage assembly Removing the fan cage assembly on page 172 5 Remove the media cage see Removing the media cage on page 176 6 Disconnect the cable from the back of the LCD system information display panel Note To disconnect the cable press evenly on the connector re...

Page 263: ...tion display panel follow all packaging instructions and use any packaging materials for shipping that are supplied to you Media cage Retention bracket Figure 196 Retention bracket removal Media cage LCD system information display panel Figure 197 LCD system information display panel removal Chapter 5 Removing and replacing components 247 ...

Page 264: ...sary 3 Remove the top cover see Removing the top cover on page 146 4 Remove the fan cage assembly Removing the fan cage assembly on page 172 5 1 Pull the tab on the LCD retention bracket to the left to disengage the retention bracket 2 Rotate the retention bracket to remove it from the server 6 Carefully insert the LCD system information display panel into place 7 Hinge the retention bracket into ...

Page 265: ... it clicks into place 10 Connect the LCD panel assembly cable to the system board The following illustration shows the cable routing for the LCD panel assembly Retention bracket Figure 200 Retention bracket installation LCD panel assembly Figure 201 LCD panel assembly installation Chapter 5 Removing and replacing components 249 ...

Page 266: ...lete the following steps 1 Read the safety information that begins on Safety on page vii and Installation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessary 3 Remove the top cover see Removing the top cover on page 146 4 Remove the fan cage assembly Removing the fan cage assembly on page 172 5 Remove the media cag...

Page 267: ...he bezel along the hooks to remove it from the media cage 7 1 Pull the tab on the LCD retention bracket to the left to disengage the retention bracket 2 Rotate the retention bracket to remove it from the server Snaps Hooks Figure 203 Snaps the rear side of the media cage Media cage Media cage bezel Figure 204 Media cage bezel removal Chapter 5 Removing and replacing components 251 ...

Page 268: ...slot on the media cage and push it until it clicks into place Media cage Retention bracket Figure 205 Retention bracket removal Media cage LCD system information display panel Alignment pins Figure 206 LCD system information display panel installation 252 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 269: ...n the rear side of the media cage bezel into slots on the media cage The following illustration shows the location of three hooks 11 Rotate the media cage bezel and snap it into place Media cage Retention bracket Figure 207 Retention bracket installation Snaps Hooks Figure 208 Hooks the rear side of the media cage Chapter 5 Removing and replacing components 253 ...

Page 270: ...ion panel complete the following steps Procedure 1 Read the safety information that begins on Safety on page vii and Installation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessary 3 Remove the top cover see Removing the top cover on page 146 4 Disconnect the cable from the back of the operator information panel a...

Page 271: ...n panel complete the following steps Procedure 1 Read the safety information that begins on Safety on page vii and Installation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessary 3 Remove the top cover see Removing the top cover on page 146 4 Slide the operator information panel into the server until it clicks int...

Page 272: ...e cable or connector 6 Replace the top cover see Replacing the top cover on page 147 7 Slide the server into the rack 8 Reconnect the power cords and any cables that you removed 9 Turn on the peripheral devices and the server Operator information panel assembly Figure 211 Operator information panel installation Operator information LCD panel connector Operator information LCD panel cable Operator ...

Page 273: ...ow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing the security bezel Use this information to replace the security bezel About this task To replace the security bezel complete the following steps Procedure 1 Read the safety information that begins on Safety on page vii and Installation guidelines on page 283 2 1 Carefully insert the right ...

Page 274: ...age the microprocessor sockets on the system board Any damage to the microprocessor sockets may require replacing the system board v Do not allow the thermal grease on the microprocessor and heat sink to come in contact with anything Contact with any surface can compromise the thermal grease and the microprocessor socket v Dropping the microprocessor during installation or removal can damage the c...

Page 275: ...tors 6 and 7 If you are removing microprocessor 2 remove the memory modules from DIMM connectors 18 and 19 See Removing a memory module on page 166 for instructions 7 Remove the heat sink Attention Do not touch the thermal material on the bottom of the heat sink Touching the thermal material will contaminate it If the thermal material on the microprocessor or heat sink becomes contaminated you mus...

Page 276: ...ide up on a clean flat surface 8 Open the microprocessor socket release levers and retainer Heat sink release lever Figure 216 Heat sink retention module release lever Heat sink release lever Lock tab Heat sink Figure 217 Heat sink removal 260 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 277: ...s in the unlocked position If the installation tool handle is not in the unlocked position use the following instructions for your installation tool v 1 lift the interlock latch and hold it up while you 2 twist the microprocessor installation tool handle counterclockwise to the unlocked position and then release the interlock latch The following illustration of the installation tool shows the loca...

Page 278: ... the installation tool on the microprocessor The installation tool rests flush on the socket only when it is aligned correctly H Figure 219 Installation tool handle adjustment E 5 x 6 x x v 3 E 5 x 6 x x v 4 E5 x6xx v3 E5 x6xx v4 E5 x6xx v3 E5 x6xx v4 Lock Position Unlock Position Figure 220 Locked and unlocked positions 262 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 279: ...ing on the size of microprocessor and then lift the microprocessor out of the socket d Lift the microprocessor out of the socket Microprocessor Installation tool Figure 221 Installation tool alignment Handle Installation tool Microprocessor Figure 222 Installation tool handle adjustment Chapter 5 Removing and replacing components 263 ...

Page 280: ...e the microprocessor installation tool to install a microprocessor Failing to use the microprocessor installation tool may damage the microprocessor sockets on the system board Any damage to the microprocessor sockets may require replacing the system board v The server supports up to two Intel Xeon E5 2600 v3 series multi core microprocessors which are designed for the LGA 2011 socket See http www...

Page 281: ... and other code updates for your server go to http www ibm com supportportal v The microprocessor speeds are automatically set for this server therefore you do not have to set any microprocessor frequency selection jumpers or switches v If the thermal grease protective cover for example a plastic cap or tape liner is removed from the heat sink do not touch the thermal grease on the bottom of the h...

Page 282: ...r see Removing the top cover on page 146 4 Remove the air baffle see Removing the air baffle on page 148 5 If you are replacing microprocessor 1 remove the memory modules from DIMM connectors 6 and 7 If you are replacing microprocessor 2 remove the memory modules from DIMM connectors 18 and 19 See Removing a memory module on page 166 for instructions 6 Rotate the heat sink retention module release...

Page 283: ...assis or any unpainted metal surface on any other grounded rack component then carefully remove the microprocessor from the package Note Do not touch the microprocessor contacts Contaminants on the microprocessor contacts such as oil from your skin can cause connection failures between the contacts and the socket b Align the installation tool with the microprocessor socket and lower down the insta...

Page 284: ... until you can not twist the handle any further then lift the installation tool out of the socket The following illustrations show the installation tool in the locked and unlocked positions Installation tool Microprocessor Alignment pins Figure 227 Installation tool alignment Figure 228 Installation tool handle adjustment 268 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 285: ...he bottom of the heat sink or on top of the microprocessor Touching the thermal material will contaminate it 9 Remove the cover from the retainer bracket if one is present Store the cover in a safe place E 5 x 6 x x v 3 E 5 x 6 x x v 4 E5 x6xx v3 E5 x6xx v4 E5 x6xx v3 E5 x6xx v4 Lock Position Unlock Position Figure 229 Installation tool Microprocessor Figure 230 Installation tool removal Chapter 5...

Page 286: ...se the microprocessor retainer on the microprocessor socket b Identify which release lever is labeled as the first release lever to close and close it c Close the second release lever on the microprocessor socket 11 Install the heat sink Dust cover Figure 231 Socket cover removal 1 3 2 Microprocessor release lever Microprocessor release lever Figure 232 Microprocessor socket levers and retainer en...

Page 287: ...ease on page 273 for more information a Remove the plastic protective cover from the bottom of the heat sink b Grasp the heat sink firmly as the following illustration to avoid possible damage to the heat sink c Position the heat sink over the microprocessor The heat sink is keyed to assist with proper alignment Heat sink Thermal grease Flange Figure 233 Thermal grease Figure 234 Heat sink Chapter...

Page 288: ...d hook it underneath the lock tab 12 Reinstall the air baffle see Replacing the air baffle on page 149 13 Install the top cover see Replacing the top cover on page 147 14 Slide the server into the rack 15 Reconnect the power cords and any cables that you removed Retainer bracket tabs Heat sink release lever Lock tab Heat sink Figure 235 Heat sink installation Heat sink release lever Heat sink Figu...

Page 289: ... page vii v Read the Installation guidelines on page 283 v Read Handling static sensitive devices on page 285 To replace damaged or contaminated thermal grease on the microprocessor and heat sink complete the following steps Procedure 1 Place the heat sink on a clean work surface 2 Remove the cleaning pad from its package and unfold it completely 3 Use the cleaning pad to wipe the thermal grease f...

Page 290: ...al devices and disconnect the power cords and all external cables 3 Remove the top cover see Removing the top cover on page 146 4 Remove the air baffle see Removing the air baffle on page 148 5 Remove the heat sink see Removing a microprocessor and heat sink on page 258 Attention When you remove a microprocessor and heat sink be sure to keep each heat sink with its microprocessor for reinstallatio...

Page 291: ...dure 1 Read the safety information that begins on Safety on page vii and Installation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables 3 Remove the top cover see Removing the top cover on page 146 4 Remove the air baffle see Removing the air baffle on page 148 5 Align the retention module with the holes on the system board 6...

Page 292: ...ure that you have the latest firmware or a copy of the pre existing firmware before you proceed 2 When you replace the system board make sure that you remove the Integrated Management Module Advanced Upgrade and place it on the new system board For information about the Advanced Upgrade see Using the remote presence and blue screen capture features on page 57 3 Before you replace the system board ...

Page 293: ...ID controller on page 183 11 Remove the paddle card module see Removing the power paddle module on page 150 12 Remove the memory modules and set them aside on a static protective surface for reinstallation see Removing a memory module on page 166 Note Make a note of the location of each DIMM as you remove it so that you can later reinstall it in the same connector 13 Trained technician only Remove...

Page 294: ... slightly and carefully remove it from the chassis being careful not to damage any surrounding components Note Use the system board handles to lift the system board only Do not attempt to lift the server using the system board handles 17 1 Push the system board toward the broadside of the server and 2 lift the system board up Thumb screws System board handles Figure 241 System board removal 278 Sy...

Page 295: ...D image Make sure that you have the latest firmware or a copy of the pre existing firmware before you proceed See Updating the firmware on page 43 Updating the Universal Unique Identifier UUID on page 64 and Updating the DMI SMBIOS data on page 66 for more information 3 When you replace the system board make sure that you remove the Integrated Management Module Advanced Upgrade and place it on the...

Page 296: ...ns on Safety on page vii Handling static sensitive devices on page 285 and Installation guidelines on page 283 2 Align the system board with the slots on the side of the chassis and lower the right side into the chassis first then lower the other side of the system board into the chassis 3 1 Slide the system board toward the rear of the server to secure it in place 4 2 Tighten the two thumbscrews ...

Page 297: ...nstall the fan cage assembly see Replacing the fan cage assembly on page 173 13 Install the top cover see Replacing the top cover on page 147 14 Push the power supplies back into the server 15 Slide the server into the rack 16 Reconnect the power cords and any cables that you removed 17 Turn on the peripheral devices and the server 18 Start the Setup utility and reset the configuration v Set the s...

Page 298: ...se the best practices to apply current firmware and device driver updates for the server and optional devices To download the IBM System x Firmware Update Best Practices document go to www ibm com support entry portal docdisplay lndocid MIGR 5082923 brandind 5000008 Additional hints and tips are available from the following sites v IBM support http www ibm com supportportal v System x configuratio...

Page 299: ...e the code For additional information about tools for updating managing and deploying firmware see the ToolsCenter for System x and BladeCenter at http publib boulder ibm com infocenter toolsctr v1r0 v Before you install optional hardware make sure that the server is working correctly Start the server and make sure that the operating system starts if an operating system is installed or that a 1999...

Page 300: ...sure that the following requirements are met v Each of the drive bays has a drive or a filler panel and electromagnetic compatibility EMC shield installed in it v Each of the power supply bays has a power supply or a filler installed in it v If the server has redundant power each of the power supply bays has a power supply installed in it v There is adequate space around the server to allow the se...

Page 301: ... Attention Static electricity can damage the server and other electronic devices To avoid damage keep static sensitive devices in their static protective packages until you are ready to install them To reduce the possibility of damage from electrostatic discharge observe the following precautions v Limit your movement Movement can cause static electricity to build up around you v The use of a grou...

Page 302: ...te the following steps Procedure 1 Read the safety information that begins on Safety on page vii and Installation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessary 3 Remove the top cover see Removing the top cover on page 146 4 Remove the two 4 drive filler panels 5 Pull the hard disk drives or fillers out of the...

Page 303: ... power configuration cables to the system board 2 5 inch HDD simple swap backplate Figure 245 2 5 inch simple swap hot swap hard disk drive backplate assembly backplane installation Chapter 5 Removing and replacing components 287 ...

Page 304: ...d disk drive on page 155 11 Install the top cover see Replacing the top cover on page 147 12 Slide the server into the rack 13 Reconnect the power cords and any cables that you removed 14 Turn on the peripheral devices and the server SAS signal cable Power configuration cable Figure 246 8x2 5 inch simple swap hard disk drive with hardware RAID cabling 288 System x3650 M5 Type 5462 Installation and...

Page 305: ...afety information that begins on Safety on page vii and Installation guidelines on page 283 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessary 3 Remove the cover see Removing the top cover on page 146 4 Pull the hard disk drives or fillers out of the server slightly to disengage them from the backplates For more information see Removing...

Page 306: ... simple swap backplate Plungers Figure 247 3 5 inch simple swap backplate assembly hot swap hard disk drive backplane SAS signal cable Power configuration cable Figure 248 8x3 5 inch simple swap hard disk drive with hardware RAID cabling 290 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 307: ...2 5 inch hot swap HDD assembly kit contact your IBM sales representative or IBM reseller The 8x 2 5 inch hot swap HDD assembly kit contains the following components v Eight 2 5 inch HDD fillers v One hot swap backplane v One power configuration cable 150 mm v One power configuration cable 230 mm v One mini SAS HD Y cable right angle 905 950 mm v One mini SAS HD Y cable 580 590 mm Note 1 The 8x 2 5...

Page 308: ...op of the backplane cage until the backplane is locked in place Note You can connect the cables to the drive backplane before installing the backplane onto the cage or you can connect the cables after you install the backplane if that is easier for you 8 Connect SAS signal and power configuration cables to the backplane and the system board as the following illustrations v If the new backplane is ...

Page 309: ...ower configuration cable SAS signal cable SAS 0 SAS 1 2 5 inch HDD hot swap backplane Power configuration cable SAS signal cable SAS 0 SAS 1 Figure 251 Cable connections SAS signal cables Power configuration cables SAS 0 SAS 1 SAS 0 SAS 1 Figure 252 Cable routing Chapter 5 Removing and replacing components 293 ...

Page 310: ...lustration 2 5 inch HDD hot swap backplane Power configuration cable SAS signal cable SAS 0 SAS 1 2 5 inch HDD hot swap backplane Power configuration cable SAS signal cable SAS 0 SAS 1 2 5 inch HDD hot swap backplane Power configuration cable SAS signal cable SAS 0 SAS 1 Figure 253 Cable connections 294 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 311: ... the following illustration Note Use right angle mini SAS HD Y cable to connect to PCI expansion slots 4 SAS signal cables Power configuration cables SAS 0 SAS 1 SAS 0 SAS 1 SAS 0 SAS 1 Figure 254 Cable routing Chapter 5 Removing and replacing components 295 ...

Page 312: ... hot swap backplane expander 2 5 inch HDD hot swap backplane Power configuration cable SAS signal cable SAS signal cable Figure 255 Cable connection SAS signal cables Power configuration cables SAS 0 SAS 1 SAS 0 SAS 1 SAS 1 SAS 0 Figure 256 Cable routing 296 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 313: ...ller The 8x 2 5 inch hot swap HDD assembly with expander kit contains the following components v Eight 2 5 inch HDD fillers v One expander v Two power configuration cables 230 mm v One power configuration cable 260 mm v One mini SAS HD Y cable 580 590 mm v One mini SAS HD cable 350 mm v One mini SAS HD cable 150 mm v Two mini SAS HD cables 250 mm Note The 8x 2 5 inch hot swap HDD assembly with exp...

Page 314: ...e cage and push the backplane forward into the release latch on top of the backplane cage until the backplane is locked in place Note You can connect the cables to the drive backplane before installing the backplane onto the cage or you can connect the cables after you install the backplane if that is easier for you 9 Connect mini SAS HD cables power configuration and Mini SAS HD Y cable which com...

Page 315: ...ect and route cables as the following illustrations 2 5 inch HDD hot swap backplane Power configuration cable SAS signal cable Power configuration cable 2 5 inch HDD hot swap backplane expander Figure 259 Cable connections SAS signal cables Power configuration cables SAS 0 SAS 1 SAS 1 SAS 0 Figure 260 Cable routing Chapter 5 Removing and replacing components 299 ...

Page 316: ... hot swap backplane Power configuration cable SAS signal cable Power configuration cable 2 5 inch HDD hot swap backplane expander 2 5 inch HDD hot swap backplane Power configuration cable SAS signal cable SAS signal cable Figure 261 Cable connections 300 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 317: ...1 SAS 0 SAS 1 SAS 1 SAS 0 Figure 262 Cable routing 2 5 inch HDD hot swap backplane Power configuration cable SAS signal cable Power configuration cable 2 5 inch HDD hot swap backplane expander Power configuration cable 2 5 inch HDD hot swap backplane expander SAS signal cable Figure 263 Cable connections Chapter 5 Removing and replacing components 301 ...

Page 318: ...mation about installing device drivers see the documentation that comes with each device If the server has an optional RAID adapter and you have installed or removed a hard disk drive see the documentation that comes with the RAID adapter for information about reconfiguring the disk arrays If you have installed a USB hypervisor memory key on the SAS riser card see the user s guide that comes with ...

Page 319: ...led devices 3 Save the DSA log as a file and send it to IBM For information about transferring data and logs see How to send DSA data to IBM 4 To ship the server repackage it in the original undamaged packing material and observe IBM procedures for shipping Support information for IBM Business Partners is available at http www ibm com partnerworld How to send DSA data to IBM Use the IBM Enhanced C...

Page 320: ...304 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 321: ...t log severity is abbreviated to the first character The following severities can be displayed Info The event was recorded for audit purposes usually a user action or a change of states that is normal behavior Warning The event is not as severe as an error but if possible the condition should be corrected before it becomes an error It might also be a condition that requires additional monitoring o...

Page 322: ...ct the detected server problems For more information about IMM2 see the Integrated Management Module II User s Guide at http www ibm com support entry portal docdisplay lndocid MIGR 5089484 IMM Events that automatically notify Support You can configure the Integrated Management Module II IMM2 to automatically notify Support also known as call home if certain types of errors are encountered If you ...

Page 323: ...mentName DIMM 1 Yes 806f010c 2002ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 2 Yes 806f010c 2003ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 3 Yes 806f010c 2004ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 4 Yes 806f010c 2005ffff Uncor...

Page 324: ...13 Yes 806f010c 200effff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 14 Yes 806f010c 200fffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 15 Yes 806f010c 2010ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 16 Yes 806f010c 2011ffff Uncorrectable e...

Page 325: ... been disabled due to a detected fault Drive 0 Yes 806f010d 0401ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 1 Yes 806f010d 0402ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 2 Yes 806f010d 0403ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 3 Yes 806f010d 0404ffff The Drive ...

Page 326: ...fault Drive 15 Yes 806f010d 0410ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 16 Yes 806f010d 0411ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 17 Yes 806f010d 0412ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 18 Yes 806f010d 0413ffff The Drive StorageVolumeElementName has ...

Page 327: ...ementName has been disabled due to a detected fault Drive 31 Yes 806f011b 0701ffff The connector PhysicalConnectorElementName has encountered a configuration error Front USB Yes 806f011b 0c01ffff The connector PhysicalConnectorElementName has encountered a configuration error FP LCD Cable Yes 806f011b 2502ffff The connector PhysicalConnectorElementName has encountered a configuration error nvDIMM ...

Page 328: ... 0406ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 6 Yes 806f020d 0407ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 7 Yes 806f020d 0408ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 8 Yes 806f020d 0409ffff Failure Predicted on drive StorageVo...

Page 329: ... Yes 806f020d 0416ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 22 Yes 806f020d 0417ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 23 Yes 806f020d 0418ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 24 Yes 806f020d 0419ffff Failure Predicted on...

Page 330: ... 4 Yes 806f050c 2005ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 5 Yes 806f050c 2006ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 6 Yes 806f050c 2007ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 7 Yes 806f050c 2008ffff Memory Logging Lim...

Page 331: ...Yes 806f050c 2011ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 17 Yes 806f050c 2012ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 18 Yes 806f050c 2013ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 19 Yes 806f050c 2014ffff Memory Logging Lim...

Page 332: ...6ffff Array ComputerSystemElementName has failed Drive 6 Yes 806f060d 0407ffff Array ComputerSystemElementName has failed Drive 7 Yes 806f060d 0408ffff Array ComputerSystemElementName has failed Drive 8 Yes 806f060d 0409ffff Array ComputerSystemElementName has failed Drive 9 Yes 806f060d 040affff Array ComputerSystemElementName has failed Drive 10 Yes 806f060d 040bffff Array ComputerSystemElementN...

Page 333: ... 25 Yes 806f060d 041affff Array ComputerSystemElementName has failed Drive 26 Yes 806f060d 041bffff Array ComputerSystemElementName has failed Drive 27 Yes 806f060d 041cffff Array ComputerSystemElementName has failed Drive 28 Yes 806f060d 041dffff Array ComputerSystemElementName has failed Drive 29 Yes 806f060d 041effff Array ComputerSystemElementName has failed Drive 30 Yes 806f060d 041fffff Arra...

Page 334: ...ted CA Certificate May also be shown as 4000000200000000 or 0x4000000200000000 Severity Error Alert Category System SSL certification Serviceable No CIM Information Prefix IMM and ID 0002 SNMP Trap ID 22 Automatically notify Support No User response Make sure that the certificate that you are importing is correct and properly generated 40000003 00000000 Ethernet Data Rate modified from arg1 to arg...

Page 335: ...ng May also be shown as 4000000500000000 or 0x4000000500000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0005 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000006 00000000 Ethernet locally administered MAC address modified from arg1 to arg2 by user arg3 Explanation This message is for the use case where ...

Page 336: ...00 or 0x4000000800000000 Severity Info Alert Category System IMM Network event Serviceable No CIM Information Prefix IMM and ID 0008 SNMP Trap ID 37 Automatically notify Support No User response Information only no action is required 40000009 00000000 IP address of network interface modified from arg1 to arg2 by user arg3 Explanation This message is for the use case where user modifies the IP addr...

Page 337: ...he default gateway IP address of a Management Controller May also be shown as 4000000b00000000 or 0x4000000b00000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0011 SNMP Trap ID Automatically notify Support No User response Information only no action is required 4000000c 00000000 OS Watchdog response arg1 by arg2 Explanation This message is for the use case ...

Page 338: ...his message is for the use case where a user successfully logs in to a Management Controller May also be shown as 4000000e00000000 or 0x4000000e00000000 Severity Info Alert Category System Remote Login Serviceable No CIM Information Prefix IMM and ID 0014 SNMP Trap ID 30 Automatically notify Support No User response Information only no action is required 4000000f 00000000 Attempting to arg1 server...

Page 339: ... as 4000001100000000 or 0x4000001100000000 Severity Warning Alert Category System Remote Login Serviceable No CIM Information Prefix IMM and ID 0017 SNMP Trap ID 30 Automatically notify Support No User response Complete the following steps until the problem is solved 1 Make sure that the correct login ID and password are being used 2 Have the system administrator reset the login ID or password 400...

Page 340: ... use case where a Management Controller Event Log on a system is cleared by a user May also be shown as 4000001400000000 or 0x4000001400000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0020 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000015 00000000 Management Controller arg1 reset was initiated by use...

Page 341: ...nd configuration has been assigned statically using user data May also be shown as 4000001700000000 or 0x4000001700000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0023 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000018 00000000 LAN Ethernet arg1 interface is no longer active Explanation This message i...

Page 342: ... 4000001a00000000 or 0x4000001a00000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0026 SNMP Trap ID Automatically notify Support No User response Information only no action is required 4000001b 00000000 Management Controller arg1 Configuration restored from a file by user arg2 Explanation This message is for the use case where a user restores a Management C...

Page 343: ...pture Screen Explanation This message is for the use case where an operating system error has occurred and the screen capture failed May also be shown as 4000001d00000000 or 0x4000001d00000000 Severity Error Alert Category System other Serviceable No CIM Information Prefix IMM and ID 0029 SNMP Trap ID 22 Automatically notify Support No User response Complete the following steps until the problem i...

Page 344: ...firmware version does not match the server May also be shown as 4000001f00000000 or 0x4000001f00000000 Severity Error Alert Category System other Serviceable No CIM Information Prefix IMM and ID 0031 SNMP Trap ID 22 Automatically notify Support No User response Update the IMM firmware to a version that the server supports Important Some cluster solutions require specific code levels or coordinated...

Page 345: ...everity Error Alert Category System other Serviceable No CIM Information Prefix IMM and ID 0034 SNMP Trap ID 22 Automatically notify Support No User response Complete the following steps until the problem is solved 1 Make sure that the certificate that you are importing is correct 2 Try to import the certificate again 40000023 00000000 Flash of arg1 from arg2 succeeded for user arg3 Explanation Th...

Page 346: ...also be shown as 4000002500000000 or 0x4000002500000000 Severity Info Alert Category System Event Log 75 full Serviceable No CIM Information Prefix IMM and ID 0037 SNMP Trap ID 35 Automatically notify Support No User response Information only no action is required 40000026 00000000 The arg1 on system arg2 is 100 full Explanation This message is for the use case where a Management Controller Event ...

Page 347: ... case where a user has generated a Test Alert May also be shown as 4000002800000000 or 0x4000002800000000 Severity Info Alert Category System other Serviceable No CIM Information Prefix IMM and ID 0040 SNMP Trap ID 22 Automatically notify Support No User response Information only no action is required 40000029 00000000 Security Userid arg1 had arg2 login failures from an SSH client at IP address a...

Page 348: ...planation Domain name set by user May also be shown as 4000002b00000000 or 0x4000002b00000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0043 SNMP Trap ID Automatically notify Support No User response Information only no action is required 4000002c 00000000 Domain Source changed to arg1 by user arg2 Explanation Domain source changed by user May also be shown...

Page 349: ...shown as 4000002e00000000 or 0x4000002e00000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0046 SNMP Trap ID Automatically notify Support No User response Information only no action is required 4000002f 00000000 IPv6 enabled by user arg1 Explanation IPv6 protocol is enabled by user May also be shown as 4000002f00000000 or 0x4000002f00000000 Severity Info Ale...

Page 350: ...e shown as 4000003100000000 or 0x4000003100000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0049 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000032 00000000 IPv6 DHCP enabled by user arg1 Explanation IPv6 DHCP assignment method is enabled by user May also be shown as 4000003200000000 or 0x4000003200000...

Page 351: ...by user May also be shown as 4000003400000000 or 0x4000003400000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0052 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000035 00000000 IPv6 DHCP disabled by user arg1 Explanation IPv6 DHCP assignment method is disabled by user May also be shown as 400000350000000...

Page 352: ... May also be shown as 4000003700000000 or 0x4000003700000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0055 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000038 00000000 ENET arg1 IPv6 Static HstName arg2 IP arg3 Pref arg4 GW arg5 Explanation IPv6 Static address is active May also be shown as 40000038000...

Page 353: ...Category none Serviceable No CIM Information Prefix IMM and ID 0058 SNMP Trap ID Automatically notify Support No User response Information only no action is required 4000003b 00000000 DHCPv6 failure no IP address assigned Explanation S DHCP6 server fails to assign an IP address to a Management Controller May also be shown as 4000003b00000000 or 0x4000003b00000000 Severity Warning Alert Category no...

Page 354: ...003d 00000000 Telnet port number changed from arg1 to arg2 by user arg3 Explanation A user has modified the telnet port number May also be shown as 4000003d00000000 or 0x4000003d00000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0061 SNMP Trap ID Automatically notify Support No User response Information only no action is required 4000003e 00000000 SSH port ...

Page 355: ...o be shown as 4000004000000000 or 0x4000004000000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0064 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000041 00000000 CIM XML HTTP port number changed from arg1 to arg2 by user arg3 Explanation A user has modified the CIM HTTP port number May also be shown as 4...

Page 356: ...May also be shown as 4000004300000000 or 0x4000004300000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0067 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000044 00000000 SNMP Traps port number changed from arg1 to arg2 by user arg3 Explanation A user has modified the SNMP Traps port number May also be sho...

Page 357: ...ence port number May also be shown as 4000004600000000 or 0x4000004600000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0070 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000047 00000000 LED arg1 state changed to arg2 by arg3 Explanation A user has modified the state of an LED May also be shown as 4000004...

Page 358: ...SNMPv3 or Traps May also be shown as 4000004900000000 or 0x4000004900000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0073 SNMP Trap ID Automatically notify Support No User response Information only no action is required 4000004a 00000000 SNMP arg1 disabled by user arg2 Explanation A user disabled SNMPv1 or SNMPv3 or Traps May also be shown as 4000004a00000...

Page 359: ...00004c00000000 or 0x4000004c00000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0076 SNMP Trap ID Automatically notify Support No User response Information only no action is required 4000004d 00000000 LDAP set by user arg1 RootDN arg2 UIDSearchAttribute arg3 BindingMethod arg4 EnhancedRBS arg5 TargetName arg6 GroupFilter arg7 GroupAttribute arg8 LoginAttribu...

Page 360: ...ettings May also be shown as 4000004f00000000 or 0x4000004f00000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0079 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000050 00000000 Server General Settings set by user arg1 Name arg2 Contact arg3 Location arg4 Room arg5 RackID arg6 Rack U position arg7 Explana...

Page 361: ...e shown as 4000005200000000 or 0x4000005200000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0082 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000053 00000000 Server arg1 scheduled for every arg2 at arg3 by user arg4 Explanation A user configured a recurring Server Power Action May also be shown as 40000...

Page 362: ...synchronize settings May also be shown as 4000005500000000 or 0x4000005500000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0085 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000056 00000000 SMTP Server set by user arg1 to arg2 arg3 Explanation A user configured the SMTP server May also be shown as 400000...

Page 363: ...r3 arg9 Explanation A user configures the DNS servers May also be shown as 4000005800000000 or 0x4000005800000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0088 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000059 00000000 LAN over USB arg1 by user arg2 Explanation A user configured USB LAN May also be s...

Page 364: ...rvices May also be shown as 4000005b00000000 or 0x4000005b00000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0091 SNMP Trap ID Automatically notify Support No User response Information only no action is required 4000005c 00000000 Secure CIM XML HTTPS arg1 by user arg2 Explanation A user enables or disables Secure CIM XML services May also be shown as 400000...

Page 365: ...ty Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0094 SNMP Trap ID Automatically notify Support No User response Information only no action is required 4000005f 00000000 Server timeouts set by user arg1 EnableOSWatchdog arg2 OSWatchdogTimout arg3 EnableLoaderWatchdog arg4 LoaderTimeout arg5 Explanation A user configures Server Timeouts May also be shown as 4000005f00000...

Page 366: ...ty Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0097 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000062 00000000 Global Login General Settings set by user arg1 AuthenticationMethod arg2 LockoutPeriod arg3 SessionTimeout arg4 Explanation A user changes the Global Login General Settings May also be shown as 40000062...

Page 367: ...fy Support No User response Information only no action is required 40000064 00000000 User arg1 created Explanation A user account was created May also be shown as 4000006400000000 or 0x4000006400000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0100 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000065 000...

Page 368: ...00 or 0x4000006700000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0103 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000068 00000000 User arg1 custom privileges set arg2 Explanation User account priveleges assigned May also be shown as 4000006800000000 or 0x4000006800000000 Severity Info Alert Category ...

Page 369: ...Client key May also be shown as 4000006a00000000 or 0x4000006a00000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0106 SNMP Trap ID Automatically notify Support No User response Information only no action is required 4000006b 00000000 SSH Client key imported for user arg1 from arg2 Explanation User imported an SSH Client key May also be shown as 4000006b0000...

Page 370: ...0x4000006d00000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0109 SNMP Trap ID Automatically notify Support No User response Information only no action is required 4000006e 00000000 Alert Configuration Global Event Notification set by user arg1 RetryLimit arg2 RetryInterval arg3 EntryInterval arg4 Explanation A user changes the Global Event Notification set...

Page 371: ...user enabled the SNMP Traps configuration May also be shown as 4000007000000000 or 0x4000007000000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0112 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000071 00000000 The power cap value changed from arg1 watts to arg2 watts by user arg3 Explanation Power Cap v...

Page 372: ... shown as 4000007300000000 or 0x4000007300000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0115 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000074 00000000 The soft minimum power cap value changed from arg1 watts to arg2 watts Explanation Soft Minimum Power Cap value changed May also be shown as 400000...

Page 373: ...e shown as 4000007600000000 or 0x4000007600000000 Severity Warning Alert Category Warning Power Serviceable No CIM Information Prefix IMM and ID 0118 SNMP Trap ID 164 Automatically notify Support No User response Information only no action is required 40000077 00000000 Power capping was activated by user arg1 Explanation Power capping activated by user May also be shown as 4000007700000000 or 0x40...

Page 374: ...as 4000007900000000 or 0x4000007900000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0121 SNMP Trap ID Automatically notify Support No User response Information only no action is required 4000007a 00000000 Static Power Savings mode has been turned off by user arg1 Explanation Static Power Savings mode turned off by user May also be shown as 4000007a00000000 ...

Page 375: ...ser May also be shown as 4000007c00000000 or 0x4000007c00000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0124 SNMP Trap ID Automatically notify Support No User response Information only no action is required 4000007d 00000000 Power cap and external throttling occurred Explanation Power cap and external throttling occurred May also be shown as 4000007d00000...

Page 376: ... 0x4000007f00000000 Severity Info Alert Category none Serviceable No CIM Information Prefix IMM and ID 0127 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000080 00000000 Remote Control session started by user arg1 in arg2 mode Explanation Remote Control session started May also be shown as 4000008000000000 or 0x4000008000000000 Severity Info Al...

Page 377: ...0 Severity Info Alert Category Warning Power Serviceable No CIM Information Prefix IMM and ID 0130 SNMP Trap ID 164 Automatically notify Support No User response Information only no action is required 40000083 00000000 The new minimum power cap value has returned below the power cap value Explanation Minimum Power Cap exceeds Power Cap recovered May also be shown as 4000008300000000 or 0x400000830...

Page 378: ...level on all nodes Explanation A mismatch of FPGA firmware has been detected between nodes May also be shown as 4000008500000000 or 0x4000008500000000 Severity Error Alert Category System Other Serviceable No CIM Information Prefix IMM and ID 0133 SNMP Trap ID 22 Automatically notify Support No User response Attempt to flash the FPGA firmware to the same level on all nodes 40000086 00000000 Test C...

Page 379: ...36 SNMP Trap ID Automatically notify Support No User response Information only no action is required 40000089 00000000 Management Controller arg1 Configuration restoration from a file by user arg2 failed to complete Explanation This message is for the use case where a user restores a Management Controller configuration from a file and the restoration fails to complete May also be shown as 40000089...

Page 380: ...s has changed Explanation This message is for the use case where an IP address for the Storage Management has changed May also be shown as 4000008b00000000 or 0x4000008b00000000 Severity Info Alert Category System IMM Network event Serviceable No CIM Information Prefix IMM and ID 0139 SNMP Trap ID 37 Automatically notify Support No User response Information only no action is required 80010002 0701...

Page 381: ...is solved 1 Check power supply n LED 2 Remove the failing power supply 3 Follow actions in Power Problems and Solving Power Problems 4 Trained technician only Replace the system board n power supply number 80010204 1d01ffff Numeric sensor NumericSensorElementName going low lower critical has asserted Fan 1A 1B Tach Explanation This message is for the use case when an implementation has detected a ...

Page 382: ...serted May also be shown as 800102041d03ffff or 0x800102041d03ffff Severity Error Alert Category Critical Fan Failure Serviceable Yes CIM Information Prefix PLAT and ID 0480 SNMP Trap ID 11 Automatically notify Support No User response 1 Reseat the failing fan n which is indicated by a lit LED near the fan connector on the system board 2 Replace the failing fan n fan number 80010204 1d04ffff Numer...

Page 383: ...connector on the system board 2 Replace the failing fan n fan number 80010204 1d06ffff Numeric sensor NumericSensorElementName going low lower critical has asserted Fan 6A 6B Tach Explanation This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted May also be shown as 800102041d06ffff or 0x800102041d06ffff Severity Error Alert Category Cr...

Page 384: ...ser n 3 Replace rear hdd cage riser n n riser number 80010204 1d08ffff Numeric sensor NumericSensorElementName going low lower critical has asserted Fan Riser1B Tach Explanation This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted May also be shown as 800102041d08ffff or 0x800102041d08ffff Severity Error Alert Category Critical Fan Fai...

Page 385: ... n 3 Replace rear hdd cage riser n n riser number 80010204 1d0affff Numeric sensor NumericSensorElementName going low lower critical has asserted Fan Riser2B Tach Explanation This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted May also be shown as 800102041d0affff or 0x800102041d0affff Severity Error Alert Category Critical Fan Failur...

Page 386: ...ation 3 Trained technician only Replace system board 80010701 0702ffff Numeric sensor NumericSensorElementName going high upper non critical has asserted RS2 RR Amb Temp Explanation This message is for the use case when an implementation has detected an Upper Non critical sensor going high has asserted May also be shown as 800107010702ffff or 0x800107010702ffff Severity Warning Alert Category Warn...

Page 387: ...on 3 Trained technician only Replace system board 80010701 0704ffff Numeric sensor NumericSensorElementName going high upper non critical has asserted MID2 RR Amb Temp Explanation This message is for the use case when an implementation has detected an Upper Non critical sensor going high has asserted May also be shown as 800107010704ffff or 0x800107010704ffff Severity Warning Alert Category Warnin...

Page 388: ... more information 3 Trained technician only Replace system board 80010701 0706ffff Numeric sensor NumericSensorElementName going high upper non critical has asserted PSU FR Amb Temp Explanation This message is for the use case when an implementation has detected an Upper Non critical sensor going high has asserted May also be shown as 800107010706ffff or 0x800107010706ffff Severity Warning Alert C...

Page 389: ...cage are functional 5 Replace rear HDD drive cage 80010701 0708ffff Numeric sensor NumericSensorElementName going high upper non critical has asserted Rear BP2 Temp Explanation This message is for the use case when an implementation has detected an Upper Non critical sensor going high has asserted May also be shown as 800107010708ffff or 0x800107010708ffff Severity Warning Alert Category Warning T...

Page 390: ...g into or preventing the air from exiting the server 80010701 1402ffff Numeric sensor NumericSensorElementName going high upper non critical has asserted CPU2 VR Temp Explanation This message is for the use case when an implementation has detected an Upper Non critical sensor going high has asserted May also be shown as 800107011402ffff or 0x800107011402ffff Severity Warning Alert Category Warning...

Page 391: ...nto or preventing the air from exiting the server 80010701 1404ffff Numeric sensor NumericSensorElementName going high upper non critical has asserted DIMM CD VR Temp Explanation This message is for the use case when an implementation has detected an Upper Non critical sensor going high has asserted May also be shown as 800107011404ffff or 0x800107011404ffff Severity Warning Alert Category Warning...

Page 392: ...M GH VR Temp Explanation This message is for the use case when an implementation has detected an Upper Non critical sensor going high has asserted May also be shown as 800107011406ffff or 0x800107011406ffff Severity Warning Alert Category Warning Temperature Serviceable Yes CIM Information Prefix PLAT and ID 0490 SNMP Trap ID 12 Automatically notify Support No User response 1 Make sure that the fa...

Page 393: ... 4 Trained technician only Replace system board 80010701 3701ffff Numeric sensor NumericSensorElementName going high upper non critical has asserted Ambient Temp Explanation This message is for the use case when an implementation has detected an Upper Non critical sensor going high has asserted May also be shown as 800107013701ffff or 0x800107013701ffff Severity Warning Alert Category Warning Temp...

Page 394: ...ation 3 Trained technician only Replace system board 80010901 0702ffff Numeric sensor NumericSensorElementName going high upper critical has asserted RS2 RR Amb Temp Explanation This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109010702ffff or 0x800109010702ffff Severity Error Alert Category Critical Tempe...

Page 395: ...on 3 Trained technician only Replace system board 80010901 0704ffff Numeric sensor NumericSensorElementName going high upper critical has asserted MID2 RR Amb Temp Explanation This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109010704ffff or 0x800109010704ffff Severity Error Alert Category Critical Tempera...

Page 396: ... more information 3 Trained technician only Replace system board 80010901 0706ffff Numeric sensor NumericSensorElementName going high upper critical has asserted PSU FR Amb Temp Explanation This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109010706ffff or 0x800109010706ffff Severity Error Alert Category Cr...

Page 397: ...cage are functional 5 Replace rear HDD drive cage 80010901 0708ffff Numeric sensor NumericSensorElementName going high upper critical has asserted Rear BP2 Temp Explanation This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109010708ffff or 0x800109010708ffff Severity Error Alert Category Critical Temperatur...

Page 398: ...g into or preventing the air from exiting the server 80010901 1402ffff Numeric sensor NumericSensorElementName going high upper critical has asserted CPU2 VR Temp Explanation This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109011402ffff or 0x800109011402ffff Severity Error Alert Category Critical Temperat...

Page 399: ...nto or preventing the air from exiting the server 80010901 1404ffff Numeric sensor NumericSensorElementName going high upper critical has asserted DIMM CD VR Temp Explanation This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109011404ffff or 0x800109011404ffff Severity Error Alert Category Critical Temperat...

Page 400: ...ritical has asserted DIMM GH VR Temp Explanation This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109011406ffff or 0x800109011406ffff Severity Error Alert Category Critical Temperature Serviceable Yes CIM Information Prefix PLAT and ID 0494 SNMP Trap ID 0 Automatically notify Support No User response 1 Mak...

Page 401: ... 4 Trained technician only Replace system board 80010901 3701ffff Numeric sensor NumericSensorElementName going high upper critical has asserted Ambient Temp Explanation This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109013701ffff or 0x800109013701ffff Severity Error Alert Category Critical Temperature S...

Page 402: ...10b01 0701ffff Numeric sensor NumericSensorElementName going high upper non recoverable has asserted RS1 RR Amb Temp Explanation This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has asserted May also be shown as 80010b010701ffff or 0x80010b010701ffff Severity Error Alert Category Critical Temperature Serviceable Yes CIM Information Pre...

Page 403: ...n 3 Trained technician only Replace system board 80010b01 0703ffff Numeric sensor NumericSensorElementName going high upper non recoverable has asserted MID1 RR Amb Temp Explanation This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has asserted May also be shown as 80010b010703ffff or 0x80010b010703ffff Severity Error Alert Category Cri...

Page 404: ...ormation 3 Trained technician only Replace system board 80010b01 0705ffff Numeric sensor NumericSensorElementName going high upper non recoverable has asserted RAID RR Amb Temp Explanation This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has asserted May also be shown as 80010b010705ffff or 0x80010b010705ffff Severity Error Alert Categ...

Page 405: ...1 0707ffff Numeric sensor NumericSensorElementName going high upper non recoverable has asserted Rear BP1 Temp Explanation This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has asserted May also be shown as 80010b010707ffff or 0x80010b010707ffff Severity Error Alert Category Critical Temperature Serviceable Yes CIM Information Prefix PL...

Page 406: ...connected correctly 4 Check the fans on rear HDD cage are functional 5 Replace rear HDD drive cage 80010b01 1401ffff Numeric sensor NumericSensorElementName going high upper non recoverable has asserted CPU1 VR Temp Explanation This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has asserted May also be shown as 80010b011401ffff or 0x8001...

Page 407: ... 3 Trained technician only Replace system board 80010b01 1403ffff Numeric sensor NumericSensorElementName going high upper non recoverable has asserted DIMM AB VR Temp Explanation This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has asserted May also be shown as 80010b011403ffff or 0x80010b011403ffff Severity Error Alert Category Criti...

Page 408: ...ation 3 Trained technician only Replace system board 80010b01 1405ffff Numeric sensor NumericSensorElementName going high upper non recoverable has asserted DIMM EF VR Temp Explanation This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has asserted May also be shown as 80010b011405ffff or 0x80010b011405ffff Severity Error Alert Category ...

Page 409: ...ation 3 Trained technician only Replace system board 80010b01 2d01ffff Numeric sensor NumericSensorElementName going high upper non recoverable has asserted PCH Temp Explanation This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has asserted May also be shown as 80010b012d01ffff or 0x80010b012d01ffff Severity Error Alert Category Critica...

Page 410: ...Replace system board 80030006 2101ffff Sensor SensorElementName has deasserted Sig Verify Fail Explanation This message is for the use case when an implementation has detected a Sensor has deasserted May also be shown as 800300062101ffff or 0x800300062101ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0509 SNMP Trap ID Automatically notify Support N...

Page 411: ...shown as 8003010c2581ffff or 0x8003010c2581ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0508 SNMP Trap ID Automatically notify Support No User response 1 Replace as authorized DIMM 2 Please contact sales representative or IBM Lenovo support 8003010f 2101ffff Sensor SensorElementName has asserted IMM FW Corrupted Explanation This message is for th...

Page 412: ...o the normal state May also be shown as 8007000d2582ffff or 0x8007000d2582ffff Severity Info Alert Category Warning Other Serviceable No CIM Information Prefix PLAT and ID 0518 SNMP Trap ID 60 Automatically notify Support No User response No action information only 80070101 0c01ffff Sensor SensorElementName has transitioned from normal to non critical state Ambient Status Explanation This message ...

Page 413: ...information 3 Replace the failed ML2 card 8007010d 2582ffff Sensor SensorElementName has transitioned from normal to non critical state RAID Vol State Explanation This message is for the use case when an implementation has detected a Sensor transitioned to non critical from normal May also be shown as 8007010d2582ffff or 0x8007010d2582ffff Severity Warning Alert Category Warning Other Serviceable ...

Page 414: ...ing DISK GPT Recovery to Automatic 3 Replace the corrupt disk 8007010f 2582ffff Sensor SensorElementName has transitioned from normal to non critical state I O Resources Explanation This message is for the use case when an implementation has detected a Sensor transitioned to non critical from normal May also be shown as 8007010f2582ffff or 0x8007010f2582ffff Severity Warning Alert Category Warning...

Page 415: ... from normal to non critical state ME Recovery Explanation This message is for the use case when an implementation has detected a Sensor transitioned to non critical from normal May also be shown as 800701282e01ffff or 0x800701282e01ffff Severity Warning Alert Category Warning Other Serviceable Yes CIM Information Prefix PLAT and ID 0520 SNMP Trap ID 60 Automatically notify Support No User respons...

Page 416: ...ly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Features and specifications for more information 3 Make sure that the heat sink for microprocessor n is installed correctly 4 Trained technician only Replace microprocessor n n microprocessor number 80070202 0701ffff Sensor SensorElementName ...

Page 417: ...evere May also be shown as 800702040a02ffff or 0x800702040a02ffff Severity Error Alert Category Critical Fan Failure Serviceable Yes CIM Information Prefix PLAT and ID 0522 SNMP Trap ID 11 Automatically notify Support No User response 1 Make sure that there are no obstructions such as bundled cables to the airflow from the power supply fan 2 Replace power supply n n power supply number 80070208 0a...

Page 418: ...ke sure that there are no obstructions such as bundled cables to the airflow from the power supply fan 2 Use the IBM Power Configurator utility to ensure current system power consumption is under limitation For more information and to download the utility go to http www 03 ibm com systems bladecenter resources powerconfig html 3 Replace power supply n n power supply number 8007020c 2502ffff Sensor...

Page 419: ...etected a Sensor transitioned to critical from less severe May also be shown as 8007020c2508ffff or 0x8007020c2508ffff Severity Error Alert Category Critical Other Serviceable Yes CIM Information Prefix PLAT and ID 0522 SNMP Trap ID 50 Automatically notify Support No User response None 8007020c 250bffff Sensor SensorElementName has transitioned to critical from a less severe state nvDIMM 11 Status...

Page 420: ...restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 8007020f 2201ffff Sensor SensorElementName has transitioned to critical from a less severe state TXT ACM Module Explanation This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe May al...

Page 421: ...ts PCI 64 bit Resource 4 choose enable 80070214 2201ffff Sensor SensorElementName has transitioned to critical from a less severe state TPM Lock Explanation This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe May also be shown as 800702142201ffff or 0x800702142201ffff Severity Error Alert Category Critical Other Serviceable No CIM...

Page 422: ...date the code 4 Replace any failing device 5 Trained technician only Replace the system board 8007021b 0301ffff Sensor SensorElementName has transitioned to critical from a less severe state CPU 1 QPILinkErr Explanation This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe May also be shown as 8007021b0301ffff or 0x8007021b0301ffff ...

Page 423: ...rElementName has transitioned to critical from a less severe state ME Error Explanation This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe May also be shown as 800702282e01ffff or 0x800702282e01ffff Severity Error Alert Category Critical Other Serviceable Yes CIM Information Prefix PLAT and ID 0522 SNMP Trap ID 50 Automatically n...

Page 424: ... is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace microprocessor n n microprocessor number 80070301 2c01ffff Sensor SensorElementName has transitioned to non recoverable from a less severe...

Page 425: ...own as 800706080a01ffff or 0x800706080a01ffff Severity Error Alert Category Critical Power Serviceable Yes CIM Information Prefix PLAT and ID 0530 SNMP Trap ID 4 Automatically notify Support No User response If the specified sensor is PS n 12V OC Fault complete the following steps until the problem is solved 1 Use the IBM Power Configurator utility to determine current system power consumption For...

Page 426: ...tility go to http www 03 ibm com systems bladecenter resources powerconfig html 2 Follow actions in Power Problems and Solving Power Problems If the specified sensor is PS n 12V OV Fault complete the following steps until the problem is solved 1 Check power supply n LED 2 Remove the failing power supply 3 Trained technician only Replace the system board n power supply number If the specified senso...

Page 427: ...n added Phy Presence Jmp Explanation This message is for the use case when an implementation has detected a Device was inserted May also be shown as 8008010f2101ffff or 0x8008010f2101ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0536 SNMP Trap ID Automatically notify Support No User response No action information only 80080128 2101ffff Device Logi...

Page 428: ...er Supply Serviceable Yes CIM Information Prefix PLAT and ID 0802 SNMP Trap ID 9 Automatically notify Support No User response 1 Check the LEDs for both power supplies 2 Follow the actions in Power supply LEDs 800b010a 1e81ffff Redundancy Lost for RedundancySetElementName has asserted Fan Zone 1 Explanation This message is for the use case when Redundancy Lost has asserted May also be shown as 800...

Page 429: ...4 Reseat the fans 5 Replace the fans n fan number 800b010a 1e83ffff Redundancy Lost for RedundancySetElementName has asserted Fan Zone 3 Explanation This message is for the use case when Redundancy Lost has asserted May also be shown as 800b010a1e83ffff or 0x800b010a1e83ffff Severity Error Alert Category Critical Fan Failure Serviceable Yes CIM Information Prefix PLAT and ID 0802 SNMP Trap ID 11 A...

Page 430: ...Reseat the fans 5 Replace the fans n fan number 800b010c 2581ffff Redundancy Lost for RedundancySetElementName has asserted Backup Memory Explanation This message is for the use case when Redundancy Lost has asserted May also be shown as 800b010c2581ffff or 0x800b010c2581ffff Severity Error Alert Category Critical Memory Serviceable Yes CIM Information Prefix PLAT and ID 0802 SNMP Trap ID 41 Autom...

Page 431: ...rent condition 2 Please check and reseat the lost power cord or power supply 3 Please replace the failed power supply 800b030c 2581ffff Non redundant Sufficient Resources from Redundancy Degraded or Fully Redundant for RedundancySetElementName has asserted Backup Memory Explanation This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded or Fully Redundant t...

Page 432: ...nsumption For more information and to download the utility go to http www 03 ibm com systems bladecenter resources powerconfig html 4 Replace the power supply with higher rated power if Oversubscription_Fault seen in power supply 5 Please reseat power cords and power supplies 800b050a 1e81ffff Non redundant Insufficient Resources for RedundancySetElementName has asserted Fan Zone 1 Explanation Thi...

Page 433: ...4 Reseat the fans 5 Replace the fans n fan number 800b050a 1e83ffff Non redundant Insufficient Resources for RedundancySetElementName has asserted Fan Zone 3 Explanation This message is for the use case when a Redundancy Set has transitioned to Non redundant Insufficient Resources May also be shown as 800b050a1e83ffff or 0x800b050a1e83ffff Severity Error Alert Category Critical Fan Failure Service...

Page 434: ...Make sure that the fans are correctly installed 4 Reseat the fans 5 Replace the fans n fan number 800b050c 2581ffff Non redundant Insufficient Resources for RedundancySetElementName has asserted Backup Memory Explanation This message is for the use case when a Redundancy Set has transitioned to Non redundant Insufficient Resources May also be shown as 800b050c2581ffff or 0x800b050c2581ffff Severit...

Page 435: ... Replace the system board n microprocessor number 806f0007 0302ffff ProcessorElementName has Failed with IERR CPU 2 Explanation This message is for the use case when an implementation has detected a Processor Failed IERR Condition May also be shown as 806f00070302ffff or 0x806f00070302ffff Severity Error Alert Category Critical CPU Serviceable Yes CIM Information Prefix PLAT and ID 0042 SNMP Trap ...

Page 436: ...lementation has detected a Power Supply has been added May also be shown as 806f00080a02ffff or 0x806f00080a02ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0084 SNMP Trap ID Automatically notify Support No User response No action information only 806f0009 1301ffff PowerSupplyElementName has been turned off Host Power Explanation This message is fo...

Page 437: ...been Added May also be shown as 806f000d0401ffff or 0x806f000d0401ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0162 SNMP Trap ID 5 Automatically notify Support No User response No action information only 806f000d 0402ffff The Drive StorageVolumeElementName has been added Drive 2 Explanation This message is for the use case when an imp...

Page 438: ...as been Added May also be shown as 806f000d0404ffff or 0x806f000d0404ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0162 SNMP Trap ID 5 Automatically notify Support No User response No action information only 806f000d 0405ffff The Drive StorageVolumeElementName has been added Drive 5 Explanation This message is for the use case when an ...

Page 439: ...been Added May also be shown as 806f000d0407ffff or 0x806f000d0407ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0162 SNMP Trap ID 5 Automatically notify Support No User response No action information only 806f000d 0408ffff The Drive StorageVolumeElementName has been added Drive 8 Explanation This message is for the use case when an imp...

Page 440: ...as been Added May also be shown as 806f000d040affff or 0x806f000d040affff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0162 SNMP Trap ID 5 Automatically notify Support No User response No action information only 806f000d 040bffff The Drive StorageVolumeElementName has been added Drive 11 Explanation This message is for the use case when an...

Page 441: ... been Added May also be shown as 806f000d040dffff or 0x806f000d040dffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0162 SNMP Trap ID 5 Automatically notify Support No User response No action information only 806f000d 040effff The Drive StorageVolumeElementName has been added Drive 14 Explanation This message is for the use case when an i...

Page 442: ...has been Added May also be shown as 806f000d0410ffff or 0x806f000d0410ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0162 SNMP Trap ID 5 Automatically notify Support No User response No action information only 806f000d 0411ffff The Drive StorageVolumeElementName has been added Drive 17 Explanation This message is for the use case when a...

Page 443: ... been Added May also be shown as 806f000d0413ffff or 0x806f000d0413ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0162 SNMP Trap ID 5 Automatically notify Support No User response No action information only 806f000d 0414ffff The Drive StorageVolumeElementName has been added Drive 20 Explanation This message is for the use case when an i...

Page 444: ...has been Added May also be shown as 806f000d0416ffff or 0x806f000d0416ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0162 SNMP Trap ID 5 Automatically notify Support No User response No action information only 806f000d 0417ffff The Drive StorageVolumeElementName has been added Drive 23 Explanation This message is for the use case when a...

Page 445: ... been Added May also be shown as 806f000d0419ffff or 0x806f000d0419ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0162 SNMP Trap ID 5 Automatically notify Support No User response No action information only 806f000d 041affff The Drive StorageVolumeElementName has been added Drive 26 Explanation This message is for the use case when an i...

Page 446: ...has been Added May also be shown as 806f000d041cffff or 0x806f000d041cffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0162 SNMP Trap ID 5 Automatically notify Support No User response No action information only 806f000d 041dffff The Drive StorageVolumeElementName has been added Drive 29 Explanation This message is for the use case when a...

Page 447: ...cted no memory in the system ABR Status Explanation This message is for the use case when an implementation has detected that memory was detected in the system May also be shown as 806f000f220101ff or 0x806f000f220101ff Severity Error Alert Category Critical Memory Serviceable Yes CIM Information Prefix PLAT and ID 0794 SNMP Trap ID 41 Automatically notify Support No User response 1 Make sure that...

Page 448: ...Recover the server firmware from the backup page a Restart the server b At the prompt press F3 to recover the firmware c Update the server firmware on the primary page Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the c...

Page 449: ...ategory Critical Other Serviceable Yes CIM Information Prefix PLAT and ID 0764 SNMP Trap ID 50 Automatically notify Support No User response This is a UEFI detected event The UEFI POST error code for this event can be found in the logged IMM message text Please refer to the UEFI POST error code in the UEFI POST error code section of the Information Center for the appropriate user response Firmware...

Page 450: ... is supported for the cluster solution before you update the code 4 Remove components one at a time restarting the server each time to see if the problem goes away 5 If the problem remains trained service technician replace the system board Firmware Error Sys Boot Status 806f000f 22010cff CPU voltage mismatch detected on ProcessorElementName ABR Status Explanation This message is for the use case ...

Page 451: ...plementation has detected a Front Panel NMI Diagnostic Interrupt May also be shown as 806f00131701ffff or 0x806f00131701ffff Severity Error Alert Category Critical Other Serviceable Yes CIM Information Prefix PLAT and ID 0222 SNMP Trap ID 50 Automatically notify Support No User response If the NMI button has not been pressed complete the following steps 1 Make sure that the NMI button is not press...

Page 452: ...ce technicians only Replace the system board 806f0021 2582ffff Fault in slot PhysicalConnectorSystemElementName on system ComputerSystemElementName All PCI Error Explanation This message is for the use case when an implementation has detected a Fault in a slot May also be shown as 806f00212582ffff or 0x806f00212582ffff Severity Error Alert Category Critical Other Serviceable Yes CIM Information Pr...

Page 453: ... Replace the system board 806f0021 3001ffff Fault in slot PhysicalConnectorSystemElementName on system ComputerSystemElementName Internal RAID Explanation This message is for the use case when an implementation has detected a Fault in a slot May also be shown as 806f00213001ffff or 0x806f00213001ffff Severity Error Alert Category Critical Other Serviceable Yes CIM Information Prefix PLAT and ID 03...

Page 454: ...se 1 Turn off the server and disconnect the power cords Reconnect the power cords and restart the server 2 If the problem remains trained technician only replace the system board 806f0107 0301ffff An Over Temperature Condition has been detected on ProcessorElementName CPU 1 Explanation This message is for the use case when an implementation has detected an Over Temperature Condition Detected for P...

Page 455: ...e that the heat sink for microprocessor n is installed correctly 3 Trained technician only Replace microprocessor n n microprocessor number 806f0108 0a01ffff PowerSupplyElementName has Failed Power Supply 1 Explanation This message is for the use case when an implementation has detected a Power Supply has failed May also be shown as 806f01080a01ffff or 0x806f01080a01ffff Severity Error Alert Categ...

Page 456: ...01ffff or 0x806f01091301ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0108 SNMP Trap ID Automatically notify Support No User response No action information only 806f010c 2001ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 1 Explanation This message is for the use case when an implementation has d...

Page 457: ...Memory Serviceable Yes CIM Information Prefix PLAT and ID 0138 SNMP Trap ID 41 Automatically notify Support Yes User response 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 3 If the problem ...

Page 458: ...10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the server to the power source and restart the server 8 Trained technician only Replace the affected microprocessor 806f010c 2004ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 4 Explanation This message is for the use case when an implementation has detected a Memo...

Page 459: ...heck the microprocessor socket pins for any damaged pins If a damage is found replace the system board 6 Trained technician only Replace the affected microprocessor 7 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the server to the power source and restart the server 8 Trai...

Page 460: ... 4 If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 5 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 6 Trained technician only Replace the affected microprocessor 7 Manu...

Page 461: ...rror Alert Category Critical Memory Serviceable Yes CIM Information Prefix PLAT and ID 0138 SNMP Trap ID 41 Automatically notify Support Yes User response 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or mic...

Page 462: ...10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the server to the power source and restart the server 8 Trained technician only Replace the affected microprocessor 806f010c 200bffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 11 Explanation This message is for the use case when an implementation has detected a Mem...

Page 463: ...heck the microprocessor socket pins for any damaged pins If a damage is found replace the system board 6 Trained technician only Replace the affected microprocessor 7 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the server to the power source and restart the server 8 Trai...

Page 464: ... 4 If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 5 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 6 Trained technician only Replace the affected microprocessor 7 Manu...

Page 465: ...Error Alert Category Critical Memory Serviceable Yes CIM Information Prefix PLAT and ID 0138 SNMP Trap ID 41 Automatically notify Support Yes User response 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or mi...

Page 466: ...10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the server to the power source and restart the server 8 Trained technician only Replace the affected microprocessor 806f010c 2012ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 18 Explanation This message is for the use case when an implementation has detected a Mem...

Page 467: ...heck the microprocessor socket pins for any damaged pins If a damage is found replace the system board 6 Trained technician only Replace the affected microprocessor 7 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the server to the power source and restart the server 8 Trai...

Page 468: ... 4 If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 5 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 6 Trained technician only Replace the affected microprocessor 7 Manu...

Page 469: ...Error Alert Category Critical Memory Serviceable Yes CIM Information Prefix PLAT and ID 0138 SNMP Trap ID 41 Automatically notify Support Yes User response 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or mi...

Page 470: ...0 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the server to the power source and restart the server 8 Trained technician only Replace the affected microprocessor 806f010c 2581ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName All DIMMS Explanation This message is for the use case when an implementation has detected a Me...

Page 471: ... components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 0401ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 1 Explanation This message is for the use case when an implementation has detected a Drive was Disabled ...

Page 472: ...c Hard disk drive backplane n hard disk drive number 806f010d 0403ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 3 Explanation This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0403ffff or 0x806f010d0403ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Ye...

Page 473: ...ard disk drive backplane n hard disk drive number 806f010d 0405ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 5 Explanation This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0405ffff or 0x806f010d0405ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes C...

Page 474: ...c Hard disk drive backplane n hard disk drive number 806f010d 0407ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 7 Explanation This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0407ffff or 0x806f010d0407ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Ye...

Page 475: ...ard disk drive backplane n hard disk drive number 806f010d 0409ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 9 Explanation This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0409ffff or 0x806f010d0409ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes C...

Page 476: ...c Hard disk drive backplane n hard disk drive number 806f010d 040bffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 11 Explanation This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d040bffff or 0x806f010d040bffff Severity Error Alert Category Critical Hard Disk drive Serviceable Y...

Page 477: ...ard disk drive backplane n hard disk drive number 806f010d 040dffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 13 Explanation This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d040dffff or 0x806f010d040dffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes ...

Page 478: ...c Hard disk drive backplane n hard disk drive number 806f010d 040fffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 15 Explanation This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d040fffff or 0x806f010d040fffff Severity Error Alert Category Critical Hard Disk drive Serviceable Y...

Page 479: ...ard disk drive backplane n hard disk drive number 806f010d 0411ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 17 Explanation This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0411ffff or 0x806f010d0411ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes ...

Page 480: ...c Hard disk drive backplane n hard disk drive number 806f010d 0413ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 19 Explanation This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0413ffff or 0x806f010d0413ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Y...

Page 481: ...ard disk drive backplane n hard disk drive number 806f010d 0415ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 21 Explanation This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0415ffff or 0x806f010d0415ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes ...

Page 482: ...c Hard disk drive backplane n hard disk drive number 806f010d 0417ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 23 Explanation This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0417ffff or 0x806f010d0417ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Y...

Page 483: ...ard disk drive backplane n hard disk drive number 806f010d 0419ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 25 Explanation This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0419ffff or 0x806f010d0419ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes ...

Page 484: ...c Hard disk drive backplane n hard disk drive number 806f010d 041bffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 27 Explanation This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d041bffff or 0x806f010d041bffff Severity Error Alert Category Critical Hard Disk drive Serviceable Y...

Page 485: ...ard disk drive backplane n hard disk drive number 806f010d 041dffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 29 Explanation This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d041dffff or 0x806f010d041dffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes ...

Page 486: ...c Hard disk drive backplane n hard disk drive number 806f010d 041fffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 31 Explanation This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d041fffff or 0x806f010d041fffff Severity Error Alert Category Critical Hard Disk drive Serviceable Y...

Page 487: ...red on system ComputerSystemElementName CPU 1 PECI Explanation This message is for the use case when an implementation has detected a Bus Timeout May also be shown as 806f01130301ffff or 0x806f01130301ffff Severity Error Alert Category Critical Other Serviceable Yes CIM Information Prefix PLAT and ID 0224 SNMP Trap ID 50 Automatically notify Support No User response 1 Reseat the microprocessor and...

Page 488: ... solved 1 Reseat the power paddle cable on the system board 2 Replace the power paddle cable 3 Trained technician only Replace the supercap n n supercap number 4 Trained technician only Replace the system board Front Video 806f011b 0c01ffff The connector PhysicalConnectorElementName has encountered a configuration error FP LCD Cable Explanation This message is for the use case when an implementati...

Page 489: ... Trained technician only Replace the system board 806f011b 2505ffff The connector PhysicalConnectorElementName has encountered a configuration error nvDIMM 05 Cable Explanation This message is for the use case when an implementation has detected an Interconnect Configuration Error May also be shown as 806f011b2505ffff or 0x806f011b2505ffff Severity Error Alert Category Critical Other Serviceable Y...

Page 490: ...r 4 Trained technician only Replace the system board 806f011b 250bffff The connector PhysicalConnectorElementName has encountered a configuration error nvDIMM 11 Cable Explanation This message is for the use case when an implementation has detected an Interconnect Configuration Error May also be shown as 806f011b250bffff or 0x806f011b250bffff Severity Error Alert Category Critical Other Serviceabl...

Page 491: ...s detected a Managed Element is Absent May also be shown as 806f01250c01ffff or 0x806f01250c01ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0392 SNMP Trap ID Automatically notify Support No User response No action information only 806f0125 1001ffff ManagedElementName detected as absent PCI Riser 1 Explanation This message is for the use case when ...

Page 492: ... shown as 806f0125100bffff or 0x806f0125100bffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0392 SNMP Trap ID Automatically notify Support No User response Please ensure the PCI riser 1 has been installed correctly 806f0125 2c01ffff ManagedElementName detected as absent ML2 Card Explanation This message is for the use case when an implementation has...

Page 493: ... Replace the system board n microprocessor number 806f0207 0302ffff ProcessorElementName has Failed with FRB1 BIST condition CPU 2 Explanation This message is for the use case when an implementation has detected a Processor Failed FRB1 BIST condition May also be shown as 806f02070302ffff or 0x806f02070302ffff Severity Error Alert Category Critical CPU Serviceable Yes CIM Information Prefix PLAT an...

Page 494: ... adapter to see if the problem is follwed adapter if not replace the adapter 5 Trained technician only Replace microprocessor n 6 Trained technician only Replace the system board n microprocessor number 806f020d 0400ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 0 Explanation This message is for the use case when an implementation has detected an...

Page 495: ...ard disk drive backplane n hard disk drive number 806f020d 0402ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 2 Explanation This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0402ffff or 0x806f020d0402ffff Severity Warning Alert Category System Predicted Failure Servicea...

Page 496: ...c Hard disk drive backplane n hard disk drive number 806f020d 0404ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 4 Explanation This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0404ffff or 0x806f020d0404ffff Severity Warning Alert Category System Predicted Failure Servi...

Page 497: ...ard disk drive backplane n hard disk drive number 806f020d 0406ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 6 Explanation This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0406ffff or 0x806f020d0406ffff Severity Warning Alert Category System Predicted Failure Servicea...

Page 498: ...c Hard disk drive backplane n hard disk drive number 806f020d 0408ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 8 Explanation This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0408ffff or 0x806f020d0408ffff Severity Warning Alert Category System Predicted Failure Servi...

Page 499: ...rd disk drive backplane n hard disk drive number 806f020d 040affff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 10 Explanation This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d040affff or 0x806f020d040affff Severity Warning Alert Category System Predicted Failure Servicea...

Page 500: ...c Hard disk drive backplane n hard disk drive number 806f020d 040cffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 12 Explanation This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d040cffff or 0x806f020d040cffff Severity Warning Alert Category System Predicted Failure Serv...

Page 501: ...ard disk drive backplane n hard disk drive number 806f020d 040effff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 14 Explanation This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d040effff or 0x806f020d040effff Severity Warning Alert Category System Predicted Failure Service...

Page 502: ...c Hard disk drive backplane n hard disk drive number 806f020d 0410ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 16 Explanation This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0410ffff or 0x806f020d0410ffff Severity Warning Alert Category System Predicted Failure Serv...

Page 503: ...ard disk drive backplane n hard disk drive number 806f020d 0412ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 18 Explanation This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0412ffff or 0x806f020d0412ffff Severity Warning Alert Category System Predicted Failure Service...

Page 504: ...c Hard disk drive backplane n hard disk drive number 806f020d 0414ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 20 Explanation This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0414ffff or 0x806f020d0414ffff Severity Warning Alert Category System Predicted Failure Serv...

Page 505: ...ard disk drive backplane n hard disk drive number 806f020d 0416ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 22 Explanation This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0416ffff or 0x806f020d0416ffff Severity Warning Alert Category System Predicted Failure Service...

Page 506: ...c Hard disk drive backplane n hard disk drive number 806f020d 0418ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 24 Explanation This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0418ffff or 0x806f020d0418ffff Severity Warning Alert Category System Predicted Failure Serv...

Page 507: ...ard disk drive backplane n hard disk drive number 806f020d 041affff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 26 Explanation This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d041affff or 0x806f020d041affff Severity Warning Alert Category System Predicted Failure Service...

Page 508: ...c Hard disk drive backplane n hard disk drive number 806f020d 041cffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 28 Explanation This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d041cffff or 0x806f020d041cffff Severity Warning Alert Category System Predicted Failure Serv...

Page 509: ...ard disk drive backplane n hard disk drive number 806f020d 041effff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 30 Explanation This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d041effff or 0x806f020d041effff Severity Warning Alert Category System Predicted Failure Service...

Page 510: ...f0223 2101ffff Powering off system ComputerSystemElementName initiated by WatchdogElementName IPMI Watchdog Explanation This message is for the use case when an implementation has detected a Poweroff by Watchdog has occurred May also be shown as 806f02232101ffff or 0x806f02232101ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0372 SNMP Trap ID Autom...

Page 511: ...se Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Make sure that the DIMMs are firmly seated and no foreign material is found in the DIMM connector Then retry with the same DIMM 3 If t...

Page 512: ...ined service technician only If the problem is related to microprocessor socket pins replace the system board 806f030c 2003ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 3 Explanation This message is for the use case when an implementation has detected a Memory Scrub failure May also be shown as 806f030c2003ffff or 0x806f030c2003ffff Severity Error Alert Categ...

Page 513: ...al or is damaged replace the system board 6 Trained service technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained service technician only If the problem is related to microprocessor socket pins replace the system board 806f030c 2005ffff Scrub Failure for PhysicalMemoryElementName on S...

Page 514: ...s 4 If the problem occurs on the same DIMM connector swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 5 If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained service technician only Remove the...

Page 515: ...AT and ID 0136 SNMP Trap ID 41 Automatically notify Support No User response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Make sure that the DIMMs are firmly seated and no foreign ma...

Page 516: ...ined service technician only If the problem is related to microprocessor socket pins replace the system board 806f030c 200affff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 10 Explanation This message is for the use case when an implementation has detected a Memory Scrub failure May also be shown as 806f030c200affff or 0x806f030c200affff Severity Error Alert Cate...

Page 517: ...al or is damaged replace the system board 6 Trained service technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained service technician only If the problem is related to microprocessor socket pins replace the system board 806f030c 200cffff Scrub Failure for PhysicalMemoryElementName on S...

Page 518: ...s 4 If the problem occurs on the same DIMM connector swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 5 If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained service technician only Remove the...

Page 519: ...LAT and ID 0136 SNMP Trap ID 41 Automatically notify Support No User response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Make sure that the DIMMs are firmly seated and no foreign m...

Page 520: ...ined service technician only If the problem is related to microprocessor socket pins replace the system board 806f030c 2011ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 17 Explanation This message is for the use case when an implementation has detected a Memory Scrub failure May also be shown as 806f030c2011ffff or 0x806f030c2011ffff Severity Error Alert Cate...

Page 521: ...al or is damaged replace the system board 6 Trained service technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained service technician only If the problem is related to microprocessor socket pins replace the system board 806f030c 2013ffff Scrub Failure for PhysicalMemoryElementName on S...

Page 522: ...s 4 If the problem occurs on the same DIMM connector swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 5 If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained service technician only Remove the...

Page 523: ...LAT and ID 0136 SNMP Trap ID 41 Automatically notify Support No User response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Make sure that the DIMMs are firmly seated and no foreign m...

Page 524: ...ined service technician only If the problem is related to microprocessor socket pins replace the system board 806f030c 2018ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 24 Explanation This message is for the use case when an implementation has detected a Memory Scrub failure May also be shown as 806f030c2018ffff or 0x806f030c2018ffff Severity Error Alert Cate...

Page 525: ...the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d0401ffff or 0x806f030d0401ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0170 SNMP Trap ID Automatically notify Support No User response No action information only 806f030d 0402ffff Hot Spare enabled for ComputerSystemElementName Drive 2 Expla...

Page 526: ...Spare has been Enabled May also be shown as 806f030d0404ffff or 0x806f030d0404ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0170 SNMP Trap ID Automatically notify Support No User response No action information only 806f030d 0405ffff Hot Spare enabled for ComputerSystemElementName Drive 5 Explanation This message is for the use case when an impleme...

Page 527: ...re has been Enabled May also be shown as 806f030d0407ffff or 0x806f030d0407ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0170 SNMP Trap ID Automatically notify Support No User response No action information only 806f030d 0408ffff Hot Spare enabled for ComputerSystemElementName Drive 8 Explanation This message is for the use case when an implementa...

Page 528: ...Spare has been Enabled May also be shown as 806f030d040affff or 0x806f030d040affff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0170 SNMP Trap ID Automatically notify Support No User response No action information only 806f030d 040bffff Hot Spare enabled for ComputerSystemElementName Drive 11 Explanation This message is for the use case when an implem...

Page 529: ...are has been Enabled May also be shown as 806f030d040dffff or 0x806f030d040dffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0170 SNMP Trap ID Automatically notify Support No User response No action information only 806f030d 040effff Hot Spare enabled for ComputerSystemElementName Drive 14 Explanation This message is for the use case when an implemen...

Page 530: ... Spare has been Enabled May also be shown as 806f030d0410ffff or 0x806f030d0410ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0170 SNMP Trap ID Automatically notify Support No User response No action information only 806f030d 0411ffff Hot Spare enabled for ComputerSystemElementName Drive 17 Explanation This message is for the use case when an imple...

Page 531: ...are has been Enabled May also be shown as 806f030d0413ffff or 0x806f030d0413ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0170 SNMP Trap ID Automatically notify Support No User response No action information only 806f030d 0414ffff Hot Spare enabled for ComputerSystemElementName Drive 20 Explanation This message is for the use case when an implemen...

Page 532: ... Spare has been Enabled May also be shown as 806f030d0416ffff or 0x806f030d0416ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0170 SNMP Trap ID Automatically notify Support No User response No action information only 806f030d 0417ffff Hot Spare enabled for ComputerSystemElementName Drive 23 Explanation This message is for the use case when an imple...

Page 533: ...are has been Enabled May also be shown as 806f030d0419ffff or 0x806f030d0419ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0170 SNMP Trap ID Automatically notify Support No User response No action information only 806f030d 041affff Hot Spare enabled for ComputerSystemElementName Drive 26 Explanation This message is for the use case when an implemen...

Page 534: ... Spare has been Enabled May also be shown as 806f030d041cffff or 0x806f030d041cffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0170 SNMP Trap ID Automatically notify Support No User response No action information only 806f030d 041dffff Hot Spare enabled for ComputerSystemElementName Drive 29 Explanation This message is for the use case when an imple...

Page 535: ... 0x806f030d041fffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0170 SNMP Trap ID Automatically notify Support No User response No action information only 806f0313 1701ffff A software NMI has occurred on system ComputerSystemElementName NMI State Explanation This message is for the use case when an implementation has detected a Software NMI May also ...

Page 536: ...hat Memory has been Disabled May also be shown as 806f040c2001ffff or 0x806f040c2001ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0131 SNMP Trap ID Automatically notify Support No User response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached...

Page 537: ...etup utility or the Advanced Settings Utility ASU 806f040c 2003ffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 3 Explanation This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2003ffff or 0x806f040c2003ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and...

Page 538: ...e Setup utility or the Advanced Settings Utility ASU 806f040c 2005ffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 5 Explanation This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2005ffff or 0x806f040c2005ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT ...

Page 539: ...etup utility or the Advanced Settings Utility ASU 806f040c 2007ffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 7 Explanation This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2007ffff or 0x806f040c2007ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and...

Page 540: ...e Setup utility or the Advanced Settings Utility ASU 806f040c 2009ffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 9 Explanation This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2009ffff or 0x806f040c2009ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT ...

Page 541: ...etup utility or the Advanced Settings Utility ASU 806f040c 200bffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 11 Explanation This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c200bffff or 0x806f040c200bffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT an...

Page 542: ...e Setup utility or the Advanced Settings Utility ASU 806f040c 200dffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 13 Explanation This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c200dffff or 0x806f040c200dffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT...

Page 543: ...etup utility or the Advanced Settings Utility ASU 806f040c 200fffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 15 Explanation This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c200fffff or 0x806f040c200fffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT an...

Page 544: ...e Setup utility or the Advanced Settings Utility ASU 806f040c 2011ffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 17 Explanation This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2011ffff or 0x806f040c2011ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT...

Page 545: ...etup utility or the Advanced Settings Utility ASU 806f040c 2013ffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 19 Explanation This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2013ffff or 0x806f040c2013ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT an...

Page 546: ...e Setup utility or the Advanced Settings Utility ASU 806f040c 2015ffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 21 Explanation This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2015ffff or 0x806f040c2015ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT...

Page 547: ...etup utility or the Advanced Settings Utility ASU 806f040c 2017ffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 23 Explanation This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2017ffff or 0x806f040c2017ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT an...

Page 548: ...ility or the Advanced Settings Utility ASU 806f040c 2581ffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName All DIMMS Explanation This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2581ffff or 0x806f040c2581ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID ...

Page 549: ...lace the riser card 806f0507 0301ffff ProcessorElementName has a Configuration Mismatch CPU 1 Explanation This message is for the use case when an implementation has detected a Processor Configuration Mismatch has occurred May also be shown as 806f05070301ffff or 0x806f05070301ffff Severity Error Alert Category Critical CPU Serviceable Yes CIM Information Prefix PLAT and ID 0062 SNMP Trap ID 40 Au...

Page 550: ...y Replace microprocessor n n microprocessor number 806f0507 2584ffff ProcessorElementName has a Configuration Mismatch All CPUs Explanation This message is for the use case when an implementation has detected a Processor Configuration Mismatch has occurred May also be shown as 806f05072584ffff or 0x806f05072584ffff Severity Error Alert Category Critical CPU Serviceable Yes CIM Information Prefix P...

Page 551: ...chnician only Replace the affected microprocessor 806f050c 2002ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 2 Explanation This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2002ffff or 0x806f050c2002ffff Severity Warning Alert Category Warning Memory ...

Page 552: ... technician only Replace the affected microprocessor 806f050c 2004ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 4 Explanation This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2004ffff or 0x806f050c2004ffff Severity Warning Alert Category Warning Memo...

Page 553: ...chnician only Replace the affected microprocessor 806f050c 2006ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 6 Explanation This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2006ffff or 0x806f050c2006ffff Severity Warning Alert Category Warning Memory ...

Page 554: ... technician only Replace the affected microprocessor 806f050c 2008ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 8 Explanation This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2008ffff or 0x806f050c2008ffff Severity Warning Alert Category Warning Memo...

Page 555: ...hnician only Replace the affected microprocessor 806f050c 200affff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 10 Explanation This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c200affff or 0x806f050c200affff Severity Warning Alert Category Warning Memory ...

Page 556: ... technician only Replace the affected microprocessor 806f050c 200cffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 12 Explanation This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c200cffff or 0x806f050c200cffff Severity Warning Alert Category Warning Mem...

Page 557: ...chnician only Replace the affected microprocessor 806f050c 200effff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 14 Explanation This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c200effff or 0x806f050c200effff Severity Warning Alert Category Warning Memory...

Page 558: ... technician only Replace the affected microprocessor 806f050c 2010ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 16 Explanation This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2010ffff or 0x806f050c2010ffff Severity Warning Alert Category Warning Mem...

Page 559: ...chnician only Replace the affected microprocessor 806f050c 2012ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 18 Explanation This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2012ffff or 0x806f050c2012ffff Severity Warning Alert Category Warning Memory...

Page 560: ... technician only Replace the affected microprocessor 806f050c 2014ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 20 Explanation This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2014ffff or 0x806f050c2014ffff Severity Warning Alert Category Warning Mem...

Page 561: ...chnician only Replace the affected microprocessor 806f050c 2016ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 22 Explanation This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2016ffff or 0x806f050c2016ffff Severity Warning Alert Category Warning Memory...

Page 562: ... technician only Replace the affected microprocessor 806f050c 2018ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 24 Explanation This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2018ffff or 0x806f050c2018ffff Severity Warning Alert Category Warning Mem...

Page 563: ...ign material or is damaged replace the system board 5 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 6 Trained technician only Replace the affected microprocessor 806f050d 0400ffff Array ComputerSystemElementName is in critical condition Drive 0 Explanation This message is for th...

Page 564: ...ard disk drive that is indicated by a lit status LED 806f050d 0402ffff Array ComputerSystemElementName is in critical condition Drive 2 Explanation This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0402ffff or 0x806f050d0402ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLA...

Page 565: ... disk drive that is indicated by a lit status LED 806f050d 0404ffff Array ComputerSystemElementName is in critical condition Drive 4 Explanation This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0404ffff or 0x806f050d0404ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT a...

Page 566: ...ard disk drive that is indicated by a lit status LED 806f050d 0406ffff Array ComputerSystemElementName is in critical condition Drive 6 Explanation This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0406ffff or 0x806f050d0406ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLA...

Page 567: ... disk drive that is indicated by a lit status LED 806f050d 0408ffff Array ComputerSystemElementName is in critical condition Drive 8 Explanation This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0408ffff or 0x806f050d0408ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT a...

Page 568: ...rd disk drive that is indicated by a lit status LED 806f050d 040affff Array ComputerSystemElementName is in critical condition Drive 10 Explanation This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d040affff or 0x806f050d040affff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLA...

Page 569: ... disk drive that is indicated by a lit status LED 806f050d 040cffff Array ComputerSystemElementName is in critical condition Drive 12 Explanation This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d040cffff or 0x806f050d040cffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT ...

Page 570: ...ard disk drive that is indicated by a lit status LED 806f050d 040effff Array ComputerSystemElementName is in critical condition Drive 14 Explanation This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d040effff or 0x806f050d040effff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PL...

Page 571: ... disk drive that is indicated by a lit status LED 806f050d 0410ffff Array ComputerSystemElementName is in critical condition Drive 16 Explanation This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0410ffff or 0x806f050d0410ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT ...

Page 572: ...ard disk drive that is indicated by a lit status LED 806f050d 0412ffff Array ComputerSystemElementName is in critical condition Drive 18 Explanation This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0412ffff or 0x806f050d0412ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PL...

Page 573: ... disk drive that is indicated by a lit status LED 806f050d 0414ffff Array ComputerSystemElementName is in critical condition Drive 20 Explanation This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0414ffff or 0x806f050d0414ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT ...

Page 574: ...ard disk drive that is indicated by a lit status LED 806f050d 0416ffff Array ComputerSystemElementName is in critical condition Drive 22 Explanation This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0416ffff or 0x806f050d0416ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PL...

Page 575: ... disk drive that is indicated by a lit status LED 806f050d 0418ffff Array ComputerSystemElementName is in critical condition Drive 24 Explanation This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0418ffff or 0x806f050d0418ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT ...

Page 576: ...ard disk drive that is indicated by a lit status LED 806f050d 041affff Array ComputerSystemElementName is in critical condition Drive 26 Explanation This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d041affff or 0x806f050d041affff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PL...

Page 577: ... disk drive that is indicated by a lit status LED 806f050d 041cffff Array ComputerSystemElementName is in critical condition Drive 28 Explanation This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d041cffff or 0x806f050d041cffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT ...

Page 578: ...ard disk drive that is indicated by a lit status LED 806f050d 041effff Array ComputerSystemElementName is in critical condition Drive 30 Explanation This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d041effff or 0x806f050d041effff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PL...

Page 579: ... Explanation This message is for the use case when an implementation has detected a PCI SERR May also be shown as 806f05132582ffff or 0x806f05132582ffff Severity Error Alert Category Critical Other Serviceable Yes CIM Information Prefix PLAT and ID 0234 SNMP Trap ID 50 Automatically notify Support No User response 1 Check the PCI LED 2 Reseat the affected adapters and riser card 3 Update the serve...

Page 580: ...ode is supported for the cluster solution before you update the code 4 Remove components one at a time restarting the server each time to see if the problem goes away 5 If the problem remains trained service technician replace the system board 806f0607 0301ffff An SM BIOS Uncorrectable CPU complex error for ProcessorElementName has asserted CPU 1 Explanation This message is for the use case when a...

Page 581: ...Replace the incompatible microprocessor 806f0607 2584ffff An SM BIOS Uncorrectable CPU complex error for ProcessorElementName has asserted All CPUs Explanation This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted May also be shown as 806f06072584ffff or 0x806f06072584ffff Severity Error Alert Category Critical CPU Serviceable Yes CIM Information Prefix PLAT...

Page 582: ...tage 806f060d 0400ffff Array ComputerSystemElementName has failed Drive 0 Explanation This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0400ffff or 0x806f060d0400ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT and ID 0176 SNMP Trap ID 5 Automatically notify Support Yes User ...

Page 583: ... disk drive that is indicated by a lit status LED 806f060d 0402ffff Array ComputerSystemElementName has failed Drive 2 Explanation This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0402ffff or 0x806f060d0402ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT and ID 0176 SNMP Tra...

Page 584: ...ard disk drive that is indicated by a lit status LED 806f060d 0404ffff Array ComputerSystemElementName has failed Drive 4 Explanation This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0404ffff or 0x806f060d0404ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT and ID 0176 SNMP ...

Page 585: ... disk drive that is indicated by a lit status LED 806f060d 0406ffff Array ComputerSystemElementName has failed Drive 6 Explanation This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0406ffff or 0x806f060d0406ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT and ID 0176 SNMP Tra...

Page 586: ...ard disk drive that is indicated by a lit status LED 806f060d 0408ffff Array ComputerSystemElementName has failed Drive 8 Explanation This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0408ffff or 0x806f060d0408ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT and ID 0176 SNMP ...

Page 587: ...disk drive that is indicated by a lit status LED 806f060d 040affff Array ComputerSystemElementName has failed Drive 10 Explanation This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d040affff or 0x806f060d040affff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT and ID 0176 SNMP Tra...

Page 588: ...ard disk drive that is indicated by a lit status LED 806f060d 040cffff Array ComputerSystemElementName has failed Drive 12 Explanation This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d040cffff or 0x806f060d040cffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT and ID 0176 SNMP...

Page 589: ... disk drive that is indicated by a lit status LED 806f060d 040effff Array ComputerSystemElementName has failed Drive 14 Explanation This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d040effff or 0x806f060d040effff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT and ID 0176 SNMP Tr...

Page 590: ...ard disk drive that is indicated by a lit status LED 806f060d 0410ffff Array ComputerSystemElementName has failed Drive 16 Explanation This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0410ffff or 0x806f060d0410ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT and ID 0176 SNMP...

Page 591: ... disk drive that is indicated by a lit status LED 806f060d 0412ffff Array ComputerSystemElementName has failed Drive 18 Explanation This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0412ffff or 0x806f060d0412ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT and ID 0176 SNMP Tr...

Page 592: ...ard disk drive that is indicated by a lit status LED 806f060d 0414ffff Array ComputerSystemElementName has failed Drive 20 Explanation This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0414ffff or 0x806f060d0414ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT and ID 0176 SNMP...

Page 593: ... disk drive that is indicated by a lit status LED 806f060d 0416ffff Array ComputerSystemElementName has failed Drive 22 Explanation This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0416ffff or 0x806f060d0416ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT and ID 0176 SNMP Tr...

Page 594: ...ard disk drive that is indicated by a lit status LED 806f060d 0418ffff Array ComputerSystemElementName has failed Drive 24 Explanation This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0418ffff or 0x806f060d0418ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT and ID 0176 SNMP...

Page 595: ... disk drive that is indicated by a lit status LED 806f060d 041affff Array ComputerSystemElementName has failed Drive 26 Explanation This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d041affff or 0x806f060d041affff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT and ID 0176 SNMP Tr...

Page 596: ...ard disk drive that is indicated by a lit status LED 806f060d 041cffff Array ComputerSystemElementName has failed Drive 28 Explanation This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d041cffff or 0x806f060d041cffff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT and ID 0176 SNMP...

Page 597: ... disk drive that is indicated by a lit status LED 806f060d 041effff Array ComputerSystemElementName has failed Drive 30 Explanation This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d041effff or 0x806f060d041effff Severity Error Alert Category Critical Hard Disk drive Serviceable Yes CIM Information Prefix PLAT and ID 0176 SNMP Tr...

Page 598: ...cted a Memory DIMM configuration error has been corrected May also be shown as 806f070c2001ffff or 0x806f070c2001ffff Severity Error Alert Category Critical Memory Serviceable Yes CIM Information Prefix PLAT and ID 0126 SNMP Trap ID 41 Automatically notify Support No User response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2...

Page 599: ...ted May also be shown as 806f070c2004ffff or 0x806f070c2004ffff Severity Error Alert Category Critical Memory Serviceable Yes CIM Information Prefix PLAT and ID 0126 SNMP Trap ID 41 Automatically notify Support No User response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2005ffff Configuration Error for PhysicalMemoryElementN...

Page 600: ...rected May also be shown as 806f070c2007ffff or 0x806f070c2007ffff Severity Error Alert Category Critical Memory Serviceable Yes CIM Information Prefix PLAT and ID 0126 SNMP Trap ID 41 Automatically notify Support No User response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2008ffff Configuration Error for PhysicalMemoryEleme...

Page 601: ...ted May also be shown as 806f070c200affff or 0x806f070c200affff Severity Error Alert Category Critical Memory Serviceable Yes CIM Information Prefix PLAT and ID 0126 SNMP Trap ID 41 Automatically notify Support No User response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 200bffff Configuration Error for PhysicalMemoryElementN...

Page 602: ...rected May also be shown as 806f070c200dffff or 0x806f070c200dffff Severity Error Alert Category Critical Memory Serviceable Yes CIM Information Prefix PLAT and ID 0126 SNMP Trap ID 41 Automatically notify Support No User response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 200effff Configuration Error for PhysicalMemoryEleme...

Page 603: ...ted May also be shown as 806f070c2010ffff or 0x806f070c2010ffff Severity Error Alert Category Critical Memory Serviceable Yes CIM Information Prefix PLAT and ID 0126 SNMP Trap ID 41 Automatically notify Support No User response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2011ffff Configuration Error for PhysicalMemoryElementN...

Page 604: ...rected May also be shown as 806f070c2013ffff or 0x806f070c2013ffff Severity Error Alert Category Critical Memory Serviceable Yes CIM Information Prefix PLAT and ID 0126 SNMP Trap ID 41 Automatically notify Support No User response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2014ffff Configuration Error for PhysicalMemoryEleme...

Page 605: ...ted May also be shown as 806f070c2016ffff or 0x806f070c2016ffff Severity Error Alert Category Critical Memory Serviceable Yes CIM Information Prefix PLAT and ID 0126 SNMP Trap ID 41 Automatically notify Support No User response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2017ffff Configuration Error for PhysicalMemoryElementN...

Page 606: ...tected a Memory DIMM configuration error has been corrected May also be shown as 806f070c2581ffff or 0x806f070c2581ffff Severity Error Alert Category Critical Memory Serviceable Yes CIM Information Prefix PLAT and ID 0126 SNMP Trap ID 41 Automatically notify Support No User response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology One of t...

Page 607: ... an Array Rebuild is in Progress May also be shown as 806f070d0402ffff or 0x806f070d0402ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0178 SNMP Trap ID Automatically notify Support No User response No action information only 806f070d 0403ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 3 Explanation This message is for ...

Page 608: ...hat an Array Rebuild is in Progress May also be shown as 806f070d0405ffff or 0x806f070d0405ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0178 SNMP Trap ID Automatically notify Support No User response No action information only 806f070d 0406ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 6 Explanation This message is f...

Page 609: ... an Array Rebuild is in Progress May also be shown as 806f070d0408ffff or 0x806f070d0408ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0178 SNMP Trap ID Automatically notify Support No User response No action information only 806f070d 0409ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 9 Explanation This message is for ...

Page 610: ...that an Array Rebuild is in Progress May also be shown as 806f070d040bffff or 0x806f070d040bffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0178 SNMP Trap ID Automatically notify Support No User response No action information only 806f070d 040cffff Rebuild in progress for Array in system ComputerSystemElementName Drive 12 Explanation This message is...

Page 611: ...t an Array Rebuild is in Progress May also be shown as 806f070d040effff or 0x806f070d040effff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0178 SNMP Trap ID Automatically notify Support No User response No action information only 806f070d 040fffff Rebuild in progress for Array in system ComputerSystemElementName Drive 15 Explanation This message is fo...

Page 612: ...that an Array Rebuild is in Progress May also be shown as 806f070d0411ffff or 0x806f070d0411ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0178 SNMP Trap ID Automatically notify Support No User response No action information only 806f070d 0412ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 18 Explanation This message is...

Page 613: ...t an Array Rebuild is in Progress May also be shown as 806f070d0414ffff or 0x806f070d0414ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0178 SNMP Trap ID Automatically notify Support No User response No action information only 806f070d 0415ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 21 Explanation This message is fo...

Page 614: ...that an Array Rebuild is in Progress May also be shown as 806f070d0417ffff or 0x806f070d0417ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0178 SNMP Trap ID Automatically notify Support No User response No action information only 806f070d 0418ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 24 Explanation This message is...

Page 615: ...t an Array Rebuild is in Progress May also be shown as 806f070d041affff or 0x806f070d041affff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0178 SNMP Trap ID Automatically notify Support No User response No action information only 806f070d 041bffff Rebuild in progress for Array in system ComputerSystemElementName Drive 27 Explanation This message is fo...

Page 616: ...that an Array Rebuild is in Progress May also be shown as 806f070d041dffff or 0x806f070d041dffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0178 SNMP Trap ID Automatically notify Support No User response No action information only 806f070d 041effff Rebuild in progress for Array in system ComputerSystemElementName Drive 30 Explanation This message is...

Page 617: ...or Firmware Change May also be shown as 806f072b2101ffff or 0x806f072b2101ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0450 SNMP Trap ID Automatically notify Support No User response No action information only IMM Recovery 806f072b 2201ffff A successful software or firmware change was detected on system ComputerSystemElementName Bkup Auto Update ...

Page 618: ...Disabled May also be shown as 806f08070302ffff or 0x806f08070302ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0061 SNMP Trap ID Automatically notify Support No User response No action information only 806f0807 2584ffff ProcessorElementName has been Disabled All CPUs Explanation This message is for the use case when an implementation has detected a...

Page 619: ...s are supported and configured correctly 6 Trained technician only Replace the system board 806f0813 2582ffff A Uncorrectable Bus Error has occurred on system ComputerSystemElementName PCIs Explanation This message is for the use case when an implementation has detected a Bus Uncorrectable Error May also be shown as 806f08132582ffff or 0x806f08132582ffff Severity Error Alert Category Critical Othe...

Page 620: ...atching 5 Trained technician only Replace the system board 806f0823 2101ffff Watchdog Timer interrupt occurred for WatchdogElementName IPMI Watchdog Explanation This message is for the use case when an implementation has detected a Watchdog Timer interrupt occurred May also be shown as 806f08232101ffff or 0x806f08232101ffff Severity Info Alert Category System Other Serviceable No CIM Information P...

Page 621: ...ay also be shown as 806f090c2003ffff or 0x806f090c2003ffff Severity Warning Alert Category System Other Serviceable Yes CIM Information Prefix PLAT and ID 0142 SNMP Trap ID 22 Automatically notify Support No User response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2004ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 4 Explanati...

Page 622: ...d May also be shown as 806f090c2006ffff or 0x806f090c2006ffff Severity Warning Alert Category System Other Serviceable Yes CIM Information Prefix PLAT and ID 0142 SNMP Trap ID 22 Automatically notify Support No User response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2007ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 7 Explan...

Page 623: ...ay also be shown as 806f090c2009ffff or 0x806f090c2009ffff Severity Warning Alert Category System Other Serviceable Yes CIM Information Prefix PLAT and ID 0142 SNMP Trap ID 22 Automatically notify Support No User response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 200affff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 10 Explanat...

Page 624: ...ed May also be shown as 806f090c200cffff or 0x806f090c200cffff Severity Warning Alert Category System Other Serviceable Yes CIM Information Prefix PLAT and ID 0142 SNMP Trap ID 22 Automatically notify Support No User response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 200dffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 13 Expl...

Page 625: ...May also be shown as 806f090c200fffff or 0x806f090c200fffff Severity Warning Alert Category System Other Serviceable Yes CIM Information Prefix PLAT and ID 0142 SNMP Trap ID 22 Automatically notify Support No User response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2010ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 16 Explana...

Page 626: ...ed May also be shown as 806f090c2012ffff or 0x806f090c2012ffff Severity Warning Alert Category System Other Serviceable Yes CIM Information Prefix PLAT and ID 0142 SNMP Trap ID 22 Automatically notify Support No User response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2013ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 19 Expl...

Page 627: ...May also be shown as 806f090c2015ffff or 0x806f090c2015ffff Severity Warning Alert Category System Other Serviceable Yes CIM Information Prefix PLAT and ID 0142 SNMP Trap ID 22 Automatically notify Support No User response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2016ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 22 Explana...

Page 628: ...otify Support No User response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f0a07 0301ffff ProcessorElementName is operating in a Degraded State CPU 1 Explanation This message is for the use case when an implementation has detected a Processor is running in the Degraded state May also be shown as 806f0a070301ffff or 0x806f0a070301ffff Severity Warning Alert Categ...

Page 629: ...cian only Replace microprocessor n n microprocessor number 806f0a0c 2001ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 1 Explanation This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2001ffff or 0x806f0a0c2001ffff...

Page 630: ...ion for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2003ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 3 Explanation This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2003ffff or 0x806f0a0c2003ffff Sever...

Page 631: ... for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2005ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 5 Explanation This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2005ffff or 0x806f0a0c2005ffff Severity...

Page 632: ...ion for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2007ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 7 Explanation This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2007ffff or 0x806f0a0c2007ffff Sever...

Page 633: ... for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2009ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 9 Explanation This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2009ffff or 0x806f0a0c2009ffff Severity...

Page 634: ...ion for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 200bffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 11 Explanation This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c200bffff or 0x806f0a0c200bffff Seve...

Page 635: ... for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 200dffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 13 Explanation This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c200dffff or 0x806f0a0c200dffff Severit...

Page 636: ...ion for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 200fffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 15 Explanation This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c200fffff or 0x806f0a0c200fffff Seve...

Page 637: ... for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2011ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 17 Explanation This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2011ffff or 0x806f0a0c2011ffff Severit...

Page 638: ...ion for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2013ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 19 Explanation This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2013ffff or 0x806f0a0c2013ffff Seve...

Page 639: ... for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2015ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 21 Explanation This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2015ffff or 0x806f0a0c2015ffff Severit...

Page 640: ...ion for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2017ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 23 Explanation This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2017ffff or 0x806f0a0c2017ffff Seve...

Page 641: ...alled and that the server cover is installed and completely closed 2 Make sure that ambient temperature is within the specifications 3 If a fan has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f0a13 0301ffff A Fatal Bus Error has occurred on system ComputerSystemElementName CPU 1 PECI Explanation This message is for the use case when an implementation has detected...

Page 642: ...or going low has deasserted May also be shown as 810100020701ffff or 0x810100020701ffff Severity Info Alert Category Warning Voltage Serviceable No CIM Information Prefix PLAT and ID 0477 SNMP Trap ID 13 Automatically notify Support No User response No action information only 81010202 0701ffff Numeric sensor NumericSensorElementName going low lower critical has deasserted CMOS Battery Explanation ...

Page 643: ...er Critical sensor going low has deasserted May also be shown as 810102041d02ffff or 0x810102041d02ffff Severity Info Alert Category Critical Fan Failure Serviceable No CIM Information Prefix PLAT and ID 0481 SNMP Trap ID 11 Automatically notify Support No User response No action information only 81010204 1d03ffff Numeric sensor NumericSensorElementName going low lower critical has deasserted Fan ...

Page 644: ...Lower Critical sensor going low has deasserted May also be shown as 810102041d05ffff or 0x810102041d05ffff Severity Info Alert Category Critical Fan Failure Serviceable No CIM Information Prefix PLAT and ID 0481 SNMP Trap ID 11 Automatically notify Support No User response No action information only 81010204 1d06ffff Numeric sensor NumericSensorElementName going low lower critical has deasserted F...

Page 645: ...wer Critical sensor going low has deasserted May also be shown as 810102041d08ffff or 0x810102041d08ffff Severity Info Alert Category Critical Fan Failure Serviceable No CIM Information Prefix PLAT and ID 0481 SNMP Trap ID 11 Automatically notify Support No User response No action information only 81010204 1d09ffff Numeric sensor NumericSensorElementName going low lower critical has deasserted Fan...

Page 646: ...er Non critical sensor going high has deasserted May also be shown as 810107010701ffff or 0x810107010701ffff Severity Info Alert Category Warning Temperature Serviceable No CIM Information Prefix PLAT and ID 0491 SNMP Trap ID 12 Automatically notify Support No User response No action information only 81010701 0702ffff Numeric sensor NumericSensorElementName going high upper non critical has deasse...

Page 647: ...pper Non critical sensor going high has deasserted May also be shown as 810107010704ffff or 0x810107010704ffff Severity Info Alert Category Warning Temperature Serviceable No CIM Information Prefix PLAT and ID 0491 SNMP Trap ID 12 Automatically notify Support No User response No action information only 81010701 0705ffff Numeric sensor NumericSensorElementName going high upper non critical has deas...

Page 648: ...n Upper Non critical sensor going high has deasserted May also be shown as 810107010707ffff or 0x810107010707ffff Severity Info Alert Category Warning Temperature Serviceable No CIM Information Prefix PLAT and ID 0491 SNMP Trap ID 12 Automatically notify Support No User response No action information only 81010701 0708ffff Numeric sensor NumericSensorElementName going high upper non critical has d...

Page 649: ...r Non critical sensor going high has deasserted May also be shown as 810107011402ffff or 0x810107011402ffff Severity Info Alert Category Warning Temperature Serviceable No CIM Information Prefix PLAT and ID 0491 SNMP Trap ID 12 Automatically notify Support No User response No action information only 81010701 1403ffff Numeric sensor NumericSensorElementName going high upper non critical has deasser...

Page 650: ...n Upper Non critical sensor going high has deasserted May also be shown as 810107011405ffff or 0x810107011405ffff Severity Info Alert Category Warning Temperature Serviceable No CIM Information Prefix PLAT and ID 0491 SNMP Trap ID 12 Automatically notify Support No User response No action information only 81010701 1406ffff Numeric sensor NumericSensorElementName going high upper non critical has d...

Page 651: ...per Non critical sensor going high has deasserted May also be shown as 810107013701ffff or 0x810107013701ffff Severity Info Alert Category Warning Temperature Serviceable No CIM Information Prefix PLAT and ID 0491 SNMP Trap ID 12 Automatically notify Support No User response No action information only 81010901 0701ffff Numeric sensor NumericSensorElementName going high upper critical has deasserte...

Page 652: ...n Upper Critical sensor going high has deasserted May also be shown as 810109010703ffff or 0x810109010703ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0495 SNMP Trap ID 0 Automatically notify Support No User response No action information only 81010901 0704ffff Numeric sensor NumericSensorElementName going high upper critical has deasserte...

Page 653: ...Upper Critical sensor going high has deasserted May also be shown as 810109010706ffff or 0x810109010706ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0495 SNMP Trap ID 0 Automatically notify Support No User response No action information only 81010901 0707ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted ...

Page 654: ... Upper Critical sensor going high has deasserted May also be shown as 810109011401ffff or 0x810109011401ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0495 SNMP Trap ID 0 Automatically notify Support No User response No action information only 81010901 1402ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted...

Page 655: ...pper Critical sensor going high has deasserted May also be shown as 810109011404ffff or 0x810109011404ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0495 SNMP Trap ID 0 Automatically notify Support No User response No action information only 81010901 1405ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted D...

Page 656: ...Upper Critical sensor going high has deasserted May also be shown as 810109012d01ffff or 0x810109012d01ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0495 SNMP Trap ID 0 Automatically notify Support No User response No action information only 81010901 3701ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted ...

Page 657: ...per Non recoverable sensor going high has deasserted May also be shown as 81010b010701ffff or 0x81010b010701ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0499 SNMP Trap ID 0 Automatically notify Support No User response No action information only 81010b01 0702ffff Numeric sensor NumericSensorElementName going high upper non recoverable has...

Page 658: ...n Upper Non recoverable sensor going high has deasserted May also be shown as 81010b010704ffff or 0x81010b010704ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0499 SNMP Trap ID 0 Automatically notify Support No User response No action information only 81010b01 0705ffff Numeric sensor NumericSensorElementName going high upper non recoverable...

Page 659: ...pper Non recoverable sensor going high has deasserted May also be shown as 81010b010707ffff or 0x81010b010707ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0499 SNMP Trap ID 0 Automatically notify Support No User response No action information only 81010b01 0708ffff Numeric sensor NumericSensorElementName going high upper non recoverable ha...

Page 660: ...pper Non recoverable sensor going high has deasserted May also be shown as 81010b011402ffff or 0x81010b011402ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0499 SNMP Trap ID 0 Automatically notify Support No User response No action information only 81010b01 1403ffff Numeric sensor NumericSensorElementName going high upper non recoverable ha...

Page 661: ...pper Non recoverable sensor going high has deasserted May also be shown as 81010b011405ffff or 0x81010b011405ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0499 SNMP Trap ID 0 Automatically notify Support No User response No action information only 81010b01 1406ffff Numeric sensor NumericSensorElementName going high upper non recoverable ha...

Page 662: ... case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b013701ffff or 0x81010b013701ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0499 SNMP Trap ID 0 Automatically notify Support No User response No action information only 81030006 2101ffff Sensor SensorElementName has ...

Page 663: ...has deasserted May also be shown as 810301081301ffff or 0x810301081301ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0509 SNMP Trap ID Automatically notify Support No User response No action information only 8103010c 2581ffff Sensor SensorElementName has deasserted Non Auth DIMMs Explanation This message is for the use case when an implementation h...

Page 664: ...l from normal May also be shown as 810701010c01ffff or 0x810701010c01ffff Severity Info Alert Category Warning Temperature Serviceable No CIM Information Prefix PLAT and ID 0521 SNMP Trap ID 12 Automatically notify Support No User response No action information only 81070101 2c01ffff Sensor SensorElementName has deasserted the transition from normal to non critical state ML2 OverTemp Explanation T...

Page 665: ...nsor has deasserted a transition to non critical from normal May also be shown as 8107010f2201ffff or 0x8107010f2201ffff Severity Info Alert Category Warning Other Serviceable No CIM Information Prefix PLAT and ID 0521 SNMP Trap ID 60 Automatically notify Support No User response No action information only 8107010f 2582ffff Sensor SensorElementName has deasserted the transition from normal to non ...

Page 666: ...detected a Sensor transition to less severe from critical May also be shown as 810702010301ffff or 0x810702010301ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0523 SNMP Trap ID 0 Automatically notify Support No User response No action information only 81070201 0302ffff Sensor SensorElementName has transitioned to a less severe state from c...

Page 667: ...r transition to less severe from critical May also be shown as 810702040a01ffff or 0x810702040a01ffff Severity Info Alert Category Critical Fan Failure Serviceable No CIM Information Prefix PLAT and ID 0523 SNMP Trap ID 11 Automatically notify Support No User response No action information only 81070204 0a02ffff Sensor SensorElementName has transitioned to a less severe state from critical PS 2 Fa...

Page 668: ...ed a Sensor transition to less severe from critical May also be shown as 810702080a02ffff or 0x810702080a02ffff Severity Info Alert Category Critical Power Serviceable No CIM Information Prefix PLAT and ID 0523 SNMP Trap ID 4 Automatically notify Support No User response No action information only 8107020d 2582ffff Sensor SensorElementName has transitioned to a less severe state from critical RAID...

Page 669: ...tected a Sensor transition to less severe from critical May also be shown as 8107020f2582ffff or 0x8107020f2582ffff Severity Info Alert Category Critical Other Serviceable No CIM Information Prefix PLAT and ID 0523 SNMP Trap ID 50 Automatically notify Support No User response No action information only 81070214 2201ffff Sensor SensorElementName has transitioned to a less severe state from critical...

Page 670: ...a Sensor transition to less severe from critical May also be shown as 8107021b0301ffff or 0x8107021b0301ffff Severity Info Alert Category Critical Other Serviceable No CIM Information Prefix PLAT and ID 0523 SNMP Trap ID 50 Automatically notify Support No User response No action information only 8107021b 0302ffff Sensor SensorElementName has transitioned to a less severe state from critical CPU 2 ...

Page 671: ...n recoverable from less severe has deasserted May also be shown as 810703010301ffff or 0x810703010301ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0525 SNMP Trap ID 0 Automatically notify Support No User response No action information only 81070301 0302ffff Sensor SensorElementName has deasserted the transition to non recoverable from a le...

Page 672: ...transition to non recoverable from less severe has deasserted May also be shown as 8107030d2582ffff or 0x8107030d2582ffff Severity Info Alert Category Critical Other Serviceable No CIM Information Prefix PLAT and ID 0525 SNMP Trap ID 50 Automatically notify Support No User response No action information only 81070608 0a01ffff Sensor SensorElementName has deasserted the transition to non recoverabl...

Page 673: ...xplanation This message is for the use case when Redundacy Lost has deasserted May also be shown as 810b010a1e81ffff or 0x810b010a1e81ffff Severity Info Alert Category Critical Fan Failure Serviceable No CIM Information Prefix PLAT and ID 0803 SNMP Trap ID 11 Automatically notify Support No User response No action information only 810b010a 1e82ffff Redundancy Lost for RedundancySetElementName has ...

Page 674: ...deasserted May also be shown as 810b010a1e84ffff or 0x810b010a1e84ffff Severity Info Alert Category Critical Fan Failure Serviceable No CIM Information Prefix PLAT and ID 0803 SNMP Trap ID 11 Automatically notify Support No User response No action information only 810b010c 2581ffff Redundancy Lost for RedundancySetElementName has deasserted Backup Memory Explanation This message is for the use cas...

Page 675: ... case when a Redundancy Set has transitioned from Non redundant Sufficient Resources May also be shown as 810b030c2581ffff or 0x810b030c2581ffff Severity Info Alert Category Warning Memory Serviceable No CIM Information Prefix PLAT and ID 0807 SNMP Trap ID 43 Automatically notify Support No User response No action information only 810b0509 1301ffff Non redundant Insufficient Resources for Redundan...

Page 676: ...d from Non redundant Insufficient Resources May also be shown as 810b050a1e82ffff or 0x810b050a1e82ffff Severity Info Alert Category Critical Fan Failure Serviceable No CIM Information Prefix PLAT and ID 0811 SNMP Trap ID 11 Automatically notify Support No User response No action information only 810b050a 1e83ffff Non redundant Insufficient Resources for RedundancySetElementName has deasserted Fan...

Page 677: ...edundancy Set has transitioned from Non redundant Insufficient Resources May also be shown as 810b050c2581ffff or 0x810b050c2581ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0811 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f0007 0301ffff ProcessorElementName has Recovered from IERR CPU 1 Explanati...

Page 678: ...r Supply has been removed May also be shown as 816f00080a01ffff or 0x816f00080a01ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0085 SNMP Trap ID Automatically notify Support No User response No action information only 816f0008 0a02ffff PowerSupplyElementName has been removed from container PhysicalPackageElementName Power Supply 2 Explanation This...

Page 679: ... Support No User response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Replace backplane 816f000d 0401ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 1 Explanation This ...

Page 680: ...firmware are at the latest level 4 Replace backplane 816f000d 0403ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 3 Explanation This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0403ffff or 0x816f000d0403ffff Severity Error Alert Category Critical Hard Disk drive Serviceable...

Page 681: ...mware are at the latest level 4 Replace backplane 816f000d 0405ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 5 Explanation This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0405ffff or 0x816f000d0405ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Ye...

Page 682: ...firmware are at the latest level 4 Replace backplane 816f000d 0407ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 7 Explanation This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0407ffff or 0x816f000d0407ffff Severity Error Alert Category Critical Hard Disk drive Serviceable...

Page 683: ...mware are at the latest level 4 Replace backplane 816f000d 0409ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 9 Explanation This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0409ffff or 0x816f000d0409ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Ye...

Page 684: ...firmware are at the latest level 4 Replace backplane 816f000d 040bffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 11 Explanation This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d040bffff or 0x816f000d040bffff Severity Error Alert Category Critical Hard Disk drive Serviceabl...

Page 685: ...mware are at the latest level 4 Replace backplane 816f000d 040dffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 13 Explanation This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d040dffff or 0x816f000d040dffff Severity Error Alert Category Critical Hard Disk drive Serviceable Y...

Page 686: ...firmware are at the latest level 4 Replace backplane 816f000d 040fffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 15 Explanation This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d040fffff or 0x816f000d040fffff Severity Error Alert Category Critical Hard Disk drive Serviceabl...

Page 687: ...mware are at the latest level 4 Replace backplane 816f000d 0411ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 17 Explanation This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0411ffff or 0x816f000d0411ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Y...

Page 688: ...firmware are at the latest level 4 Replace backplane 816f000d 0413ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 19 Explanation This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0413ffff or 0x816f000d0413ffff Severity Error Alert Category Critical Hard Disk drive Serviceabl...

Page 689: ...mware are at the latest level 4 Replace backplane 816f000d 0415ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 21 Explanation This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0415ffff or 0x816f000d0415ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Y...

Page 690: ...firmware are at the latest level 4 Replace backplane 816f000d 0417ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 23 Explanation This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0417ffff or 0x816f000d0417ffff Severity Error Alert Category Critical Hard Disk drive Serviceabl...

Page 691: ...mware are at the latest level 4 Replace backplane 816f000d 0419ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 25 Explanation This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0419ffff or 0x816f000d0419ffff Severity Error Alert Category Critical Hard Disk drive Serviceable Y...

Page 692: ...firmware are at the latest level 4 Replace backplane 816f000d 041bffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 27 Explanation This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d041bffff or 0x816f000d041bffff Severity Error Alert Category Critical Hard Disk drive Serviceabl...

Page 693: ...mware are at the latest level 4 Replace backplane 816f000d 041dffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 29 Explanation This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d041dffff or 0x816f000d041dffff Severity Error Alert Category Critical Hard Disk drive Serviceable Y...

Page 694: ...firmware are at the latest level 4 Replace backplane 816f000d 041fffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 31 Explanation This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d041fffff or 0x816f000d041fffff Severity Error Alert Category Critical Hard Disk drive Serviceabl...

Page 695: ...s detected a recovery from a Front Panel NMI Diagnostic Interrupt May also be shown as 816f00131701ffff or 0x816f00131701ffff Severity Info Alert Category Critical Other Serviceable No CIM Information Prefix PLAT and ID 0223 SNMP Trap ID 50 Automatically notify Support No User response No action information only 816f0021 2201ffff Fault condition removed on slot PhysicalConnectorElementName on syst...

Page 696: ...ult condition in a slot has been removed May also be shown as 816f00212c01ffff or 0x816f00212c01ffff Severity Info Alert Category Critical Other Serviceable No CIM Information Prefix PLAT and ID 0331 SNMP Trap ID 50 Automatically notify Support No User response No action information only 816f0021 3001ffff Fault condition removed on slot PhysicalConnectorElementName on system ComputerSystemElementN...

Page 697: ...emperature Condition has been Removed for Processor May also be shown as 816f01070301ffff or 0x816f01070301ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0037 SNMP Trap ID 0 Automatically notify Support No User response No action information only 816f0107 0302ffff An Over Temperature Condition has been removed on ProcessorElementName CPU 2 ...

Page 698: ...l operational status May also be shown as 816f01080a02ffff or 0x816f01080a02ffff Severity Info Alert Category Critical Power Serviceable No CIM Information Prefix PLAT and ID 0087 SNMP Trap ID 4 Automatically notify Support No User response No action information only 816f010c 2001ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 1 Explanat...

Page 699: ...detected a Memory uncorrectable error recovery May also be shown as 816f010c2003ffff or 0x816f010c2003ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0139 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f010c 2004ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem Memor...

Page 700: ...as detected a Memory uncorrectable error recovery May also be shown as 816f010c2006ffff or 0x816f010c2006ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0139 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f010c 2007ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem Me...

Page 701: ...etected a Memory uncorrectable error recovery May also be shown as 816f010c2009ffff or 0x816f010c2009ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0139 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f010c 200affff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem Memory...

Page 702: ...as detected a Memory uncorrectable error recovery May also be shown as 816f010c200cffff or 0x816f010c200cffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0139 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f010c 200dffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem Me...

Page 703: ...detected a Memory uncorrectable error recovery May also be shown as 816f010c200fffff or 0x816f010c200fffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0139 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f010c 2010ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem Memor...

Page 704: ...as detected a Memory uncorrectable error recovery May also be shown as 816f010c2012ffff or 0x816f010c2012ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0139 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f010c 2013ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem Me...

Page 705: ...detected a Memory uncorrectable error recovery May also be shown as 816f010c2015ffff or 0x816f010c2015ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0139 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f010c 2016ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem Memor...

Page 706: ...ed a Memory uncorrectable error recovery May also be shown as 816f010c2018ffff or 0x816f010c2018ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0139 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f010c 2581ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryEleme...

Page 707: ...as Enabled May also be shown as 816f010d0401ffff or 0x816f010d0401ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0167 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f010d 0402ffff The Drive StorageVolumeElementName has been enabled Drive 2 Explanation This message is for the use case when an i...

Page 708: ...e was Enabled May also be shown as 816f010d0404ffff or 0x816f010d0404ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0167 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f010d 0405ffff The Drive StorageVolumeElementName has been enabled Drive 5 Explanation This message is for the use case when a...

Page 709: ...as Enabled May also be shown as 816f010d0407ffff or 0x816f010d0407ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0167 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f010d 0408ffff The Drive StorageVolumeElementName has been enabled Drive 8 Explanation This message is for the use case when an i...

Page 710: ...e was Enabled May also be shown as 816f010d040affff or 0x816f010d040affff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0167 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f010d 040bffff The Drive StorageVolumeElementName has been enabled Drive 11 Explanation This message is for the use case when ...

Page 711: ...as Enabled May also be shown as 816f010d040dffff or 0x816f010d040dffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0167 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f010d 040effff The Drive StorageVolumeElementName has been enabled Drive 14 Explanation This message is for the use case when an ...

Page 712: ...e was Enabled May also be shown as 816f010d0410ffff or 0x816f010d0410ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0167 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f010d 0411ffff The Drive StorageVolumeElementName has been enabled Drive 17 Explanation This message is for the use case when ...

Page 713: ...as Enabled May also be shown as 816f010d0413ffff or 0x816f010d0413ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0167 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f010d 0414ffff The Drive StorageVolumeElementName has been enabled Drive 20 Explanation This message is for the use case when an ...

Page 714: ...e was Enabled May also be shown as 816f010d0416ffff or 0x816f010d0416ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0167 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f010d 0417ffff The Drive StorageVolumeElementName has been enabled Drive 23 Explanation This message is for the use case when ...

Page 715: ...as Enabled May also be shown as 816f010d0419ffff or 0x816f010d0419ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0167 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f010d 041affff The Drive StorageVolumeElementName has been enabled Drive 26 Explanation This message is for the use case when an ...

Page 716: ...e was Enabled May also be shown as 816f010d041cffff or 0x816f010d041cffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0167 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f010d 041dffff The Drive StorageVolumeElementName has been enabled Drive 29 Explanation This message is for the use case when ...

Page 717: ...y also be shown as 816f010d041fffff or 0x816f010d041fffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0167 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f010f 2201ffff The System ComputerSystemElementName has recovered from a firmware hang Firmware Error Explanation This message is for the use ...

Page 718: ... Installing the system board n microprocessor number 816f0113 0302ffff System ComputerSystemElementName has recovered from a bus timeout CPU 2 PECI Explanation This message is for the use case when an implemenation has detected that a system has recovered from a Bus Timeout May also be shown as 816f01130302ffff or 0x816f01130302ffff Severity Info Alert Category Critical Other Serviceable No CIM In...

Page 719: ...en an implementation has detected an Interconnect Configuration was Repaired May also be shown as 816f011b0c01ffff or 0x816f011b0c01ffff Severity Info Alert Category Critical Other Serviceable No CIM Information Prefix PLAT and ID 0267 SNMP Trap ID 50 Automatically notify Support No User response No action information only 816f0125 0c01ffff ManagedElementName detected as present Front Panel Explan...

Page 720: ... Element is now Present May also be shown as 816f01251002ffff or 0x816f01251002ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0390 SNMP Trap ID Automatically notify Support No User response No action information only 816f0125 100bffff ManagedElementName detected as present PDB Card Explanation This message is for the use case when an implementation...

Page 721: ...BIST condition May also be shown as 816f02070301ffff or 0x816f02070301ffff Severity Info Alert Category Critical CPU Serviceable No CIM Information Prefix PLAT and ID 0045 SNMP Trap ID 40 Automatically notify Support No User response No action information only 816f0207 0302ffff ProcessorElementName has Recovered from FRB1 BIST condition CPU 2 Explanation This message is for the use case when an im...

Page 722: ...Failure is no longer Predicted May also be shown as 816f020d0400ffff or 0x816f020d0400ffff Severity Info Alert Category System Predicted Failure Serviceable No CIM Information Prefix PLAT and ID 0169 SNMP Trap ID 27 Automatically notify Support No User response No action information only 816f020d 0401ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElement...

Page 723: ...ed an Array Failure is no longer Predicted May also be shown as 816f020d0403ffff or 0x816f020d0403ffff Severity Info Alert Category System Predicted Failure Serviceable No CIM Information Prefix PLAT and ID 0169 SNMP Trap ID 27 Automatically notify Support No User response No action information only 816f020d 0404ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerS...

Page 724: ...ected an Array Failure is no longer Predicted May also be shown as 816f020d0406ffff or 0x816f020d0406ffff Severity Info Alert Category System Predicted Failure Serviceable No CIM Information Prefix PLAT and ID 0169 SNMP Trap ID 27 Automatically notify Support No User response No action information only 816f020d 0407ffff Failure no longer Predicted on drive StorageVolumeElementName for array Comput...

Page 725: ...ed an Array Failure is no longer Predicted May also be shown as 816f020d0409ffff or 0x816f020d0409ffff Severity Info Alert Category System Predicted Failure Serviceable No CIM Information Prefix PLAT and ID 0169 SNMP Trap ID 27 Automatically notify Support No User response No action information only 816f020d 040affff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerS...

Page 726: ...tected an Array Failure is no longer Predicted May also be shown as 816f020d040cffff or 0x816f020d040cffff Severity Info Alert Category System Predicted Failure Serviceable No CIM Information Prefix PLAT and ID 0169 SNMP Trap ID 27 Automatically notify Support No User response No action information only 816f020d 040dffff Failure no longer Predicted on drive StorageVolumeElementName for array Compu...

Page 727: ...ted an Array Failure is no longer Predicted May also be shown as 816f020d040fffff or 0x816f020d040fffff Severity Info Alert Category System Predicted Failure Serviceable No CIM Information Prefix PLAT and ID 0169 SNMP Trap ID 27 Automatically notify Support No User response No action information only 816f020d 0410ffff Failure no longer Predicted on drive StorageVolumeElementName for array Computer...

Page 728: ...tected an Array Failure is no longer Predicted May also be shown as 816f020d0412ffff or 0x816f020d0412ffff Severity Info Alert Category System Predicted Failure Serviceable No CIM Information Prefix PLAT and ID 0169 SNMP Trap ID 27 Automatically notify Support No User response No action information only 816f020d 0413ffff Failure no longer Predicted on drive StorageVolumeElementName for array Compu...

Page 729: ...ted an Array Failure is no longer Predicted May also be shown as 816f020d0415ffff or 0x816f020d0415ffff Severity Info Alert Category System Predicted Failure Serviceable No CIM Information Prefix PLAT and ID 0169 SNMP Trap ID 27 Automatically notify Support No User response No action information only 816f020d 0416ffff Failure no longer Predicted on drive StorageVolumeElementName for array Computer...

Page 730: ...tected an Array Failure is no longer Predicted May also be shown as 816f020d0418ffff or 0x816f020d0418ffff Severity Info Alert Category System Predicted Failure Serviceable No CIM Information Prefix PLAT and ID 0169 SNMP Trap ID 27 Automatically notify Support No User response No action information only 816f020d 0419ffff Failure no longer Predicted on drive StorageVolumeElementName for array Compu...

Page 731: ...ted an Array Failure is no longer Predicted May also be shown as 816f020d041bffff or 0x816f020d041bffff Severity Info Alert Category System Predicted Failure Serviceable No CIM Information Prefix PLAT and ID 0169 SNMP Trap ID 27 Automatically notify Support No User response No action information only 816f020d 041cffff Failure no longer Predicted on drive StorageVolumeElementName for array Computer...

Page 732: ...tected an Array Failure is no longer Predicted May also be shown as 816f020d041effff or 0x816f020d041effff Severity Info Alert Category System Predicted Failure Serviceable No CIM Information Prefix PLAT and ID 0169 SNMP Trap ID 27 Automatically notify Support No User response No action information only 816f020d 041fffff Failure no longer Predicted on drive StorageVolumeElementName for array Compu...

Page 733: ... that has input that has returned to normal May also be shown as 816f03080a02ffff or 0x816f03080a02ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0099 SNMP Trap ID Automatically notify Support No User response No action information only 816f030c 2001ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 1...

Page 734: ... detected a Memory Scrub failure recovery May also be shown as 816f030c2003ffff or 0x816f030c2003ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0137 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f030c 2004ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DI...

Page 735: ...tected a Memory Scrub failure recovery May also be shown as 816f030c2006ffff or 0x816f030c2006ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0137 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f030c 2007ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM ...

Page 736: ...detected a Memory Scrub failure recovery May also be shown as 816f030c2009ffff or 0x816f030c2009ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0137 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f030c 200affff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIM...

Page 737: ...tected a Memory Scrub failure recovery May also be shown as 816f030c200cffff or 0x816f030c200cffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0137 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f030c 200dffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM ...

Page 738: ... detected a Memory Scrub failure recovery May also be shown as 816f030c200fffff or 0x816f030c200fffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0137 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f030c 2010ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DI...

Page 739: ...tected a Memory Scrub failure recovery May also be shown as 816f030c2012ffff or 0x816f030c2012ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0137 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f030c 2013ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM ...

Page 740: ... detected a Memory Scrub failure recovery May also be shown as 816f030c2015ffff or 0x816f030c2015ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0137 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f030c 2016ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DI...

Page 741: ...an implementation has detected a Memory Scrub failure recovery May also be shown as 816f030c2018ffff or 0x816f030c2018ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0137 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f030d 0400ffff Hot spare disabled for ComputerSystemElementName Drive 0 Explanation T...

Page 742: ...Spare has been Disabled May also be shown as 816f030d0402ffff or 0x816f030d0402ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0171 SNMP Trap ID Automatically notify Support No User response No action information only 816f030d 0403ffff Hot spare disabled for ComputerSystemElementName Drive 3 Explanation This message is for the use case when an imple...

Page 743: ...re has been Disabled May also be shown as 816f030d0405ffff or 0x816f030d0405ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0171 SNMP Trap ID Automatically notify Support No User response No action information only 816f030d 0406ffff Hot spare disabled for ComputerSystemElementName Drive 6 Explanation This message is for the use case when an implemen...

Page 744: ...Spare has been Disabled May also be shown as 816f030d0408ffff or 0x816f030d0408ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0171 SNMP Trap ID Automatically notify Support No User response No action information only 816f030d 0409ffff Hot spare disabled for ComputerSystemElementName Drive 9 Explanation This message is for the use case when an imple...

Page 745: ...are has been Disabled May also be shown as 816f030d040bffff or 0x816f030d040bffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0171 SNMP Trap ID Automatically notify Support No User response No action information only 816f030d 040cffff Hot spare disabled for ComputerSystemElementName Drive 12 Explanation This message is for the use case when an implem...

Page 746: ... Spare has been Disabled May also be shown as 816f030d040effff or 0x816f030d040effff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0171 SNMP Trap ID Automatically notify Support No User response No action information only 816f030d 040fffff Hot spare disabled for ComputerSystemElementName Drive 15 Explanation This message is for the use case when an imp...

Page 747: ...are has been Disabled May also be shown as 816f030d0411ffff or 0x816f030d0411ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0171 SNMP Trap ID Automatically notify Support No User response No action information only 816f030d 0412ffff Hot spare disabled for ComputerSystemElementName Drive 18 Explanation This message is for the use case when an implem...

Page 748: ... Spare has been Disabled May also be shown as 816f030d0414ffff or 0x816f030d0414ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0171 SNMP Trap ID Automatically notify Support No User response No action information only 816f030d 0415ffff Hot spare disabled for ComputerSystemElementName Drive 21 Explanation This message is for the use case when an imp...

Page 749: ...are has been Disabled May also be shown as 816f030d0417ffff or 0x816f030d0417ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0171 SNMP Trap ID Automatically notify Support No User response No action information only 816f030d 0418ffff Hot spare disabled for ComputerSystemElementName Drive 24 Explanation This message is for the use case when an implem...

Page 750: ... Spare has been Disabled May also be shown as 816f030d041affff or 0x816f030d041affff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0171 SNMP Trap ID Automatically notify Support No User response No action information only 816f030d 041bffff Hot spare disabled for ComputerSystemElementName Drive 27 Explanation This message is for the use case when an imp...

Page 751: ...are has been Disabled May also be shown as 816f030d041dffff or 0x816f030d041dffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0171 SNMP Trap ID Automatically notify Support No User response No action information only 816f030d 041effff Hot spare disabled for ComputerSystemElementName Drive 30 Explanation This message is for the use case when an implem...

Page 752: ...I has been Recovered from May also be shown as 816f03131701ffff or 0x816f03131701ffff Severity Info Alert Category Critical Other Serviceable No CIM Information Prefix PLAT and ID 0230 SNMP Trap ID 50 Automatically notify Support No User response No action information only 816f040c 2001ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 1 Explanation This message is for the ...

Page 753: ...hat Memory has been Enabled May also be shown as 816f040c2003ffff or 0x816f040c2003ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0130 SNMP Trap ID Automatically notify Support No User response No action information only 816f040c 2004ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 4 Explanation This message is for the use...

Page 754: ...d that Memory has been Enabled May also be shown as 816f040c2006ffff or 0x816f040c2006ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0130 SNMP Trap ID Automatically notify Support No User response No action information only 816f040c 2007ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 7 Explanation This message is for the ...

Page 755: ...hat Memory has been Enabled May also be shown as 816f040c2009ffff or 0x816f040c2009ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0130 SNMP Trap ID Automatically notify Support No User response No action information only 816f040c 200affff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 10 Explanation This message is for the us...

Page 756: ...ed that Memory has been Enabled May also be shown as 816f040c200cffff or 0x816f040c200cffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0130 SNMP Trap ID Automatically notify Support No User response No action information only 816f040c 200dffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 13 Explanation This message is for th...

Page 757: ...that Memory has been Enabled May also be shown as 816f040c200fffff or 0x816f040c200fffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0130 SNMP Trap ID Automatically notify Support No User response No action information only 816f040c 2010ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 16 Explanation This message is for the u...

Page 758: ...ed that Memory has been Enabled May also be shown as 816f040c2012ffff or 0x816f040c2012ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0130 SNMP Trap ID Automatically notify Support No User response No action information only 816f040c 2013ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 19 Explanation This message is for th...

Page 759: ...that Memory has been Enabled May also be shown as 816f040c2015ffff or 0x816f040c2015ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0130 SNMP Trap ID Automatically notify Support No User response No action information only 816f040c 2016ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 22 Explanation This message is for the u...

Page 760: ...mory has been Enabled May also be shown as 816f040c2018ffff or 0x816f040c2018ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0130 SNMP Trap ID Automatically notify Support No User response No action information only 816f040c 2581ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName All DIMMS Explanation This message is for the use ca...

Page 761: ...r Configuration Mismatch May also be shown as 816f05070301ffff or 0x816f05070301ffff Severity Info Alert Category Critical CPU Serviceable No CIM Information Prefix PLAT and ID 0063 SNMP Trap ID 40 Automatically notify Support No User response No action information only 816f0507 0302ffff ProcessorElementName has Recovered from a Configuration Mismatch CPU 2 Explanation This message is for the use ...

Page 762: ... the Memory Logging Limit has been Removed May also be shown as 816f050c2001ffff or 0x816f050c2001ffff Severity Info Alert Category Warning Memory Serviceable No CIM Information Prefix PLAT and ID 0145 SNMP Trap ID 43 Automatically notify Support No User response No action information only 816f050c 2002ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName D...

Page 763: ...that the Memory Logging Limit has been Removed May also be shown as 816f050c2004ffff or 0x816f050c2004ffff Severity Info Alert Category Warning Memory Serviceable No CIM Information Prefix PLAT and ID 0145 SNMP Trap ID 43 Automatically notify Support No User response No action information only 816f050c 2005ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementNa...

Page 764: ...ed that the Memory Logging Limit has been Removed May also be shown as 816f050c2007ffff or 0x816f050c2007ffff Severity Info Alert Category Warning Memory Serviceable No CIM Information Prefix PLAT and ID 0145 SNMP Trap ID 43 Automatically notify Support No User response No action information only 816f050c 2008ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElemen...

Page 765: ...that the Memory Logging Limit has been Removed May also be shown as 816f050c200affff or 0x816f050c200affff Severity Info Alert Category Warning Memory Serviceable No CIM Information Prefix PLAT and ID 0145 SNMP Trap ID 43 Automatically notify Support No User response No action information only 816f050c 200bffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementNa...

Page 766: ...ted that the Memory Logging Limit has been Removed May also be shown as 816f050c200dffff or 0x816f050c200dffff Severity Info Alert Category Warning Memory Serviceable No CIM Information Prefix PLAT and ID 0145 SNMP Trap ID 43 Automatically notify Support No User response No action information only 816f050c 200effff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryEleme...

Page 767: ... that the Memory Logging Limit has been Removed May also be shown as 816f050c2010ffff or 0x816f050c2010ffff Severity Info Alert Category Warning Memory Serviceable No CIM Information Prefix PLAT and ID 0145 SNMP Trap ID 43 Automatically notify Support No User response No action information only 816f050c 2011ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementN...

Page 768: ...ted that the Memory Logging Limit has been Removed May also be shown as 816f050c2013ffff or 0x816f050c2013ffff Severity Info Alert Category Warning Memory Serviceable No CIM Information Prefix PLAT and ID 0145 SNMP Trap ID 43 Automatically notify Support No User response No action information only 816f050c 2014ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryEleme...

Page 769: ... that the Memory Logging Limit has been Removed May also be shown as 816f050c2016ffff or 0x816f050c2016ffff Severity Info Alert Category Warning Memory Serviceable No CIM Information Prefix PLAT and ID 0145 SNMP Trap ID 43 Automatically notify Support No User response No action information only 816f050c 2017ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementN...

Page 770: ...has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2581ffff or 0x816f050c2581ffff Severity Info Alert Category Warning Memory Serviceable No CIM Information Prefix PLAT and ID 0145 SNMP Trap ID 43 Automatically notify Support No User response No action information only One of the DIMMs 816f050d 0400ffff Critical Array ComputerSystemElementName has deasserted D...

Page 771: ... Array has deasserted May also be shown as 816f050d0402ffff or 0x816f050d0402ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0175 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f050d 0403ffff Critical Array ComputerSystemElementName has deasserted Drive 3 Explanation This message is for the use...

Page 772: ...cal Array has deasserted May also be shown as 816f050d0405ffff or 0x816f050d0405ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0175 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f050d 0406ffff Critical Array ComputerSystemElementName has deasserted Drive 6 Explanation This message is for the ...

Page 773: ... Array has deasserted May also be shown as 816f050d0408ffff or 0x816f050d0408ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0175 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f050d 0409ffff Critical Array ComputerSystemElementName has deasserted Drive 9 Explanation This message is for the use...

Page 774: ...acal Array has deasserted May also be shown as 816f050d040bffff or 0x816f050d040bffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0175 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f050d 040cffff Critical Array ComputerSystemElementName has deasserted Drive 12 Explanation This message is for th...

Page 775: ...l Array has deasserted May also be shown as 816f050d040effff or 0x816f050d040effff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0175 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f050d 040fffff Critical Array ComputerSystemElementName has deasserted Drive 15 Explanation This message is for the u...

Page 776: ...acal Array has deasserted May also be shown as 816f050d0411ffff or 0x816f050d0411ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0175 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f050d 0412ffff Critical Array ComputerSystemElementName has deasserted Drive 18 Explanation This message is for th...

Page 777: ...l Array has deasserted May also be shown as 816f050d0414ffff or 0x816f050d0414ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0175 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f050d 0415ffff Critical Array ComputerSystemElementName has deasserted Drive 21 Explanation This message is for the u...

Page 778: ...acal Array has deasserted May also be shown as 816f050d0417ffff or 0x816f050d0417ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0175 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f050d 0418ffff Critical Array ComputerSystemElementName has deasserted Drive 24 Explanation This message is for th...

Page 779: ...l Array has deasserted May also be shown as 816f050d041affff or 0x816f050d041affff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0175 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f050d 041bffff Critical Array ComputerSystemElementName has deasserted Drive 27 Explanation This message is for the u...

Page 780: ...acal Array has deasserted May also be shown as 816f050d041dffff or 0x816f050d041dffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0175 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f050d 041effff Critical Array ComputerSystemElementName has deasserted Drive 30 Explanation This message is for th...

Page 781: ... CPU complex error has deasserted May also be shown as 816f06070301ffff or 0x816f06070301ffff Severity Info Alert Category Critical CPU Serviceable No CIM Information Prefix PLAT and ID 0817 SNMP Trap ID 40 Automatically notify Support No User response No action information only 816f0607 0302ffff An SM BIOS Uncorrectable CPU complex error for ProcessorElementName has deasserted CPU 2 Explanation T...

Page 782: ...wer Supply configuration is OK May also be shown as 816f06081301ffff or 0x816f06081301ffff Severity Info Alert Category Critical Power Serviceable No CIM Information Prefix PLAT and ID 0105 SNMP Trap ID 4 Automatically notify Support No User response No action information only 816f060d 0400ffff Array in system ComputerSystemElementName has been restored Drive 0 Explanation This message is for the ...

Page 783: ...Array has been Restored May also be shown as 816f060d0402ffff or 0x816f060d0402ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0177 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f060d 0403ffff Array in system ComputerSystemElementName has been restored Drive 3 Explanation This message is for t...

Page 784: ...ed Array has been Restored May also be shown as 816f060d0405ffff or 0x816f060d0405ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0177 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f060d 0406ffff Array in system ComputerSystemElementName has been restored Drive 6 Explanation This message is fo...

Page 785: ...Array has been Restored May also be shown as 816f060d0408ffff or 0x816f060d0408ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0177 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f060d 0409ffff Array in system ComputerSystemElementName has been restored Drive 9 Explanation This message is for t...

Page 786: ...ed Array has been Restored May also be shown as 816f060d040bffff or 0x816f060d040bffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0177 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f060d 040cffff Array in system ComputerSystemElementName has been restored Drive 12 Explanation This message is f...

Page 787: ...Array has been Restored May also be shown as 816f060d040effff or 0x816f060d040effff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0177 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f060d 040fffff Array in system ComputerSystemElementName has been restored Drive 15 Explanation This message is for ...

Page 788: ...ed Array has been Restored May also be shown as 816f060d0411ffff or 0x816f060d0411ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0177 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f060d 0412ffff Array in system ComputerSystemElementName has been restored Drive 18 Explanation This message is f...

Page 789: ...Array has been Restored May also be shown as 816f060d0414ffff or 0x816f060d0414ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0177 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f060d 0415ffff Array in system ComputerSystemElementName has been restored Drive 21 Explanation This message is for ...

Page 790: ...ed Array has been Restored May also be shown as 816f060d0417ffff or 0x816f060d0417ffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0177 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f060d 0418ffff Array in system ComputerSystemElementName has been restored Drive 24 Explanation This message is f...

Page 791: ...Array has been Restored May also be shown as 816f060d041affff or 0x816f060d041affff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0177 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f060d 041bffff Array in system ComputerSystemElementName has been restored Drive 27 Explanation This message is for ...

Page 792: ...ed Array has been Restored May also be shown as 816f060d041dffff or 0x816f060d041dffff Severity Info Alert Category Critical Hard Disk drive Serviceable No CIM Information Prefix PLAT and ID 0177 SNMP Trap ID 5 Automatically notify Support No User response No action information only 816f060d 041effff Array in system ComputerSystemElementName has been restored Drive 30 Explanation This message is f...

Page 793: ...figuration error has deasserted May also be shown as 816f070c2001ffff or 0x816f070c2001ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0127 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f070c 2002ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM ...

Page 794: ...cted a Memory DIMM configuration error has deasserted May also be shown as 816f070c2004ffff or 0x816f070c2004ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0127 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f070c 2005ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementNam...

Page 795: ...d a Memory DIMM configuration error has deasserted May also be shown as 816f070c2007ffff or 0x816f070c2007ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0127 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f070c 2008ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName h...

Page 796: ...cted a Memory DIMM configuration error has deasserted May also be shown as 816f070c200affff or 0x816f070c200affff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0127 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f070c 200bffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementNam...

Page 797: ...d a Memory DIMM configuration error has deasserted May also be shown as 816f070c200dffff or 0x816f070c200dffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0127 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f070c 200effff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName h...

Page 798: ...cted a Memory DIMM configuration error has deasserted May also be shown as 816f070c2010ffff or 0x816f070c2010ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0127 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f070c 2011ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementNam...

Page 799: ...d a Memory DIMM configuration error has deasserted May also be shown as 816f070c2013ffff or 0x816f070c2013ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0127 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f070c 2014ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName h...

Page 800: ...cted a Memory DIMM configuration error has deasserted May also be shown as 816f070c2016ffff or 0x816f070c2016ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0127 SNMP Trap ID 41 Automatically notify Support No User response No action information only 816f070c 2017ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementNam...

Page 801: ...tation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2581ffff or 0x816f070c2581ffff Severity Info Alert Category Critical Memory Serviceable No CIM Information Prefix PLAT and ID 0127 SNMP Trap ID 41 Automatically notify Support No User response No action information only One of the DIMMs 816f070d 0400ffff Rebuild completed for Array in system ComputerS...

Page 802: ...hat an Array Rebuild has Completed May also be shown as 816f070d0402ffff or 0x816f070d0402ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0179 SNMP Trap ID Automatically notify Support No User response No action information only 816f070d 0403ffff Rebuild completed for Array in system ComputerSystemElementName Drive 3 Explanation This message is for ...

Page 803: ... an Array Rebuild has Completed May also be shown as 816f070d0405ffff or 0x816f070d0405ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0179 SNMP Trap ID Automatically notify Support No User response No action information only 816f070d 0406ffff Rebuild completed for Array in system ComputerSystemElementName Drive 6 Explanation This message is for the...

Page 804: ...hat an Array Rebuild has Completed May also be shown as 816f070d0408ffff or 0x816f070d0408ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0179 SNMP Trap ID Automatically notify Support No User response No action information only 816f070d 0409ffff Rebuild completed for Array in system ComputerSystemElementName Drive 9 Explanation This message is for ...

Page 805: ... an Array Rebuild has Completed May also be shown as 816f070d040bffff or 0x816f070d040bffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0179 SNMP Trap ID Automatically notify Support No User response No action information only 816f070d 040cffff Rebuild completed for Array in system ComputerSystemElementName Drive 12 Explanation This message is for th...

Page 806: ...hat an Array Rebuild has Completed May also be shown as 816f070d040effff or 0x816f070d040effff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0179 SNMP Trap ID Automatically notify Support No User response No action information only 816f070d 040fffff Rebuild completed for Array in system ComputerSystemElementName Drive 15 Explanation This message is for...

Page 807: ... an Array Rebuild has Completed May also be shown as 816f070d0411ffff or 0x816f070d0411ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0179 SNMP Trap ID Automatically notify Support No User response No action information only 816f070d 0412ffff Rebuild completed for Array in system ComputerSystemElementName Drive 18 Explanation This message is for th...

Page 808: ...hat an Array Rebuild has Completed May also be shown as 816f070d0414ffff or 0x816f070d0414ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0179 SNMP Trap ID Automatically notify Support No User response No action information only 816f070d 0415ffff Rebuild completed for Array in system ComputerSystemElementName Drive 21 Explanation This message is for...

Page 809: ... an Array Rebuild has Completed May also be shown as 816f070d0417ffff or 0x816f070d0417ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0179 SNMP Trap ID Automatically notify Support No User response No action information only 816f070d 0418ffff Rebuild completed for Array in system ComputerSystemElementName Drive 24 Explanation This message is for th...

Page 810: ...hat an Array Rebuild has Completed May also be shown as 816f070d041affff or 0x816f070d041affff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0179 SNMP Trap ID Automatically notify Support No User response No action information only 816f070d 041bffff Rebuild completed for Array in system ComputerSystemElementName Drive 27 Explanation This message is for...

Page 811: ... an Array Rebuild has Completed May also be shown as 816f070d041dffff or 0x816f070d041dffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0179 SNMP Trap ID Automatically notify Support No User response No action information only 816f070d 041effff Rebuild completed for Array in system ComputerSystemElementName Drive 30 Explanation This message is for th...

Page 812: ...ected a Processor has been Enabled May also be shown as 816f08070301ffff or 0x816f08070301ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0060 SNMP Trap ID Automatically notify Support No User response No action information only 816f0807 0302ffff ProcessorElementName has been Enabled CPU 2 Explanation This message is for the use case when an impleme...

Page 813: ...ncorrectable Error May also be shown as 816f08132581ffff or 0x816f08132581ffff Severity Info Alert Category Critical Other Serviceable No CIM Information Prefix PLAT and ID 0241 SNMP Trap ID 50 Automatically notify Support No User response No action information only 816f0813 2582ffff System ComputerSystemElementName has recovered from an Uncorrectable Bus Error PCIs Explanation This message is for...

Page 814: ...plementation has detected Memory is no longer Throttled May also be shown as 816f090c2001ffff or 0x816f090c2001ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0143 SNMP Trap ID Automatically notify Support No User response No action information only 816f090c 2002ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIM...

Page 815: ...ected Memory is no longer Throttled May also be shown as 816f090c2004ffff or 0x816f090c2004ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0143 SNMP Trap ID Automatically notify Support No User response No action information only 816f090c 2005ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 5 Explanation This...

Page 816: ...detected Memory is no longer Throttled May also be shown as 816f090c2007ffff or 0x816f090c2007ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0143 SNMP Trap ID Automatically notify Support No User response No action information only 816f090c 2008ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 8 Explanation T...

Page 817: ...ected Memory is no longer Throttled May also be shown as 816f090c200affff or 0x816f090c200affff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0143 SNMP Trap ID Automatically notify Support No User response No action information only 816f090c 200bffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 11 Explanation Thi...

Page 818: ... detected Memory is no longer Throttled May also be shown as 816f090c200dffff or 0x816f090c200dffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0143 SNMP Trap ID Automatically notify Support No User response No action information only 816f090c 200effff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 14 Explanation...

Page 819: ...tected Memory is no longer Throttled May also be shown as 816f090c2010ffff or 0x816f090c2010ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0143 SNMP Trap ID Automatically notify Support No User response No action information only 816f090c 2011ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 17 Explanation Th...

Page 820: ... detected Memory is no longer Throttled May also be shown as 816f090c2013ffff or 0x816f090c2013ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0143 SNMP Trap ID Automatically notify Support No User response No action information only 816f090c 2014ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 20 Explanation...

Page 821: ...tected Memory is no longer Throttled May also be shown as 816f090c2016ffff or 0x816f090c2016ffff Severity Info Alert Category System Other Serviceable No CIM Information Prefix PLAT and ID 0143 SNMP Trap ID Automatically notify Support No User response No action information only 816f090c 2017ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 23 Explanation Th...

Page 822: ... longer running in the Degraded state May also be shown as 816f0a070301ffff or 0x816f0a070301ffff Severity Info Alert Category Warning CPU Serviceable No CIM Information Prefix PLAT and ID 0039 SNMP Trap ID 42 Automatically notify Support No User response No action information only 816f0a07 0302ffff The Processor ProcessorElementName is no longer operating in a Degraded State CPU 2 Explanation Thi...

Page 823: ...an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2002ffff or 0x816f0a0c2002ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0147 SNMP Trap ID 0 Automatically notify Support No User response No action information only 816f0a0c 2003ffff An Over Temperature Condition has been removed on the PhysicalMemo...

Page 824: ...ed an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2005ffff or 0x816f0a0c2005ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0147 SNMP Trap ID 0 Automatically notify Support No User response No action information only 816f0a0c 2006ffff An Over Temperature Condition has been removed on the PhysicalM...

Page 825: ...an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2008ffff or 0x816f0a0c2008ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0147 SNMP Trap ID 0 Automatically notify Support No User response No action information only 816f0a0c 2009ffff An Over Temperature Condition has been removed on the PhysicalMemo...

Page 826: ...ted an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c200bffff or 0x816f0a0c200bffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0147 SNMP Trap ID 0 Automatically notify Support No User response No action information only 816f0a0c 200cffff An Over Temperature Condition has been removed on the Physical...

Page 827: ... an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c200effff or 0x816f0a0c200effff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0147 SNMP Trap ID 0 Automatically notify Support No User response No action information only 816f0a0c 200fffff An Over Temperature Condition has been removed on the PhysicalMem...

Page 828: ...ted an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2011ffff or 0x816f0a0c2011ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0147 SNMP Trap ID 0 Automatically notify Support No User response No action information only 816f0a0c 2012ffff An Over Temperature Condition has been removed on the Physical...

Page 829: ... an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2014ffff or 0x816f0a0c2014ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0147 SNMP Trap ID 0 Automatically notify Support No User response No action information only 816f0a0c 2015ffff An Over Temperature Condition has been removed on the PhysicalMem...

Page 830: ...ted an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2017ffff or 0x816f0a0c2017ffff Severity Info Alert Category Critical Temperature Serviceable No CIM Information Prefix PLAT and ID 0147 SNMP Trap ID 0 Automatically notify Support No User response No action information only 816f0a0c 2018ffff An Over Temperature Condition has been removed on the Physical...

Page 831: ...eplacing the system board n microprocessor number 816f0a13 0302ffff System ComputerSystemElementName has recovered from a Fatal Bus Error CPU 2 PECI Explanation This message is for the use case when an implementation has detected that a system has recovered from a Bus Fatal Error May also be shown as 816f0a130302ffff or 0x816f0a130302ffff Severity Info Alert Category Critical Other Serviceable No ...

Page 832: ...816 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 833: ...rning A warning is not as severe as an error but if possible the condition should be corrected before it becomes an error It might also be a condition that requires additional monitoring or maintenance Error An error typically indicates a failure or critical condition that impairs service or an expected function User response The actions that you should take to resolve the event Perform the steps ...

Page 834: ...he Processor s are installed in the correct sockets according to the service information for this product If not correct that problem 4 Check IBM support site for an applicable service bulletin or UEFI firmware update that applies to this processor error 5 Trained Service technician only Replace mismatching processor Inspect Processor socket and replace the system board first if socket is damaged ...

Page 835: ...mware update that applies to this processor error 3 Trained technician only Replace the system board I 1800E I 1800E Explanation A processor model mismatch has been detected for one or more processor packages Processors have mismatched Model Number Severity Error User response Complete the following steps 1 Verify that matching processors are installed in the correct processor sockets Correct any ...

Page 836: ...ties so that adapter firmware can be updated 3 Move the adapter to a different slot If a slot is not available or error recurs replace the adapter 4 If the adapter was moved to a different slot and the error did not recur verify that this is not a system limitation Then replace the system board Also if this is not the initial installation and the error persists after adapter replacement replace th...

Page 837: ...18002 I 3818002 Explanation The firmware image capsule signature for the non booted flash bank is invalid Opposite Bank CRTM Capsule Update Signature Invalid Severity Info User response Complete the following steps 1 Update the backup UEFI image 2 If error does not persist no additional recovery action is required 3 If error persists or boot is unsuccessful Trained service technician only Replace ...

Page 838: ...ion too large for compatibility mode Severity Info User response Complete the following steps 1 Information only no action is required I 5100B I 5100B Explanation An unqualified DIMM serial number has been detected serial number found in slot of memory card Unqualified DIMM Serial Number Detected Severity Info User response Complete the following steps 1 If this information event is logged in the ...

Page 839: ... successfully Spare Copy Complete Severity Info User response Complete the following steps 1 If you have added or removed DIMMs to the system and no additional errors were detected then please ignore this message 2 Check system event log for uncorrected DIMM failures and replace those DIMMs S 1100B S 1100B Explanation CATERR IERR has asserted on processor Processor CATERR IERR has asserted Severit...

Page 840: ...ring slot to Gen1 or Gen2 may be required Gen1 Gen2 settings can be configured via F1 Setup System Settings Devices and I O Ports PCIe Gen1 Gen2 Gen3 Speed Selection or the ASU Utility 3 If problem persists then remove Adapter Card If system reboots successfully without the adapter replace that card 4 Trained Service technician only Replace the system board 5 Trained Service technician only Replac...

Page 841: ... the system 3 If problem persists contact support S 3030007 S 3030007 Explanation A firmware fault has been detected in the UEFI image Internal UEFI Firmware Fault Detected System halted Severity Error User response Complete the following steps 1 Check IBM support site for an applicable service bulletin or firmware update that applies to this error 2 Update the UEFI image 3 Replace the system boar...

Page 842: ...ck logs for probable cause 3 Undo recent system changes settings or devices added If there were no recent system changes remove all options and then remove the CMOS battery for 30 seconds to clear CMOS contents Verify that the system boots Then re install the options one at a time to locate the problem 4 Check the IBM support site for an applicable service bulletin or firmware update that applies ...

Page 843: ...Error User response Complete the following steps 1 Continue booting the sytem If the system does not reset manually reset the system 2 If the error is not reported on the subsequent boot no additional recovery action is required 3 If the error persists continue booting system and update the UEFI image 4 Trained service technician only Replace the system board S 3818007 S 3818007 Explanation The fi...

Page 844: ... requirements for sparing paring modes If problem follows a moved DIMM to a different memory channel replace that DIMM 5 Trained service technician only Remove affected Processor and inspect Processor socket pins for damaged or mis aligned pins If damage is found or this is an upgrade Processor replace the system board If there are multiple Processor s swap Processor s to move affected Procesor to...

Page 845: ... installed serviced moved or upgraded check to ensure that DIMMs are firmly seated and that no foreign material can be seen in the DIMM connector If either condition is observed correct and retry with the same DIMM Note The event Log might contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 If problem persists replace the DIMM identifi...

Page 846: ...80B9 Explanation External QPI Link Failure Detected External QPI Link Failure Detected Severity Error User response Complete the following steps 1 Check the IBM support site for an applicable service bulletin or firmware update that applies to this error 2 Inspect the processor socket for foreign debris or damage If debris is found remove the debris 3 Trained technician only If error recurs or soc...

Page 847: ...rt site for an applicable service bulletin or firmware update that applies to this error 4 Trained service technician only Replace the system board W 3058009 W 3058009 Explanation DRIVER HEALTH PROTOCOL Missing Configuration Requires Change Settings From F1 DRIVER HEALTH PROTOCOL Missing Configuration Requires Change Settings From F1 Severity Warning User response Complete the following steps 1 Go...

Page 848: ... update the current UEFI image 3 Replace the system board W 305800D W 305800D Explanation DRIVER HEALTH PROTOCOL Disconnect Controller Failed Requires Reboot DRIVER HEALTH PROTOCOL Disconnect Controller Failed Requires Reboot Severity Warning User response Complete the following steps 1 No action required The system will reboot at the end of POST 2 If the problem persists switch to the backup UEFI...

Page 849: ...ve auxilliary power from the compute node This will reboot the compute node 4 Check the IBM support site for an applicable service bulletin or firmware update that applies to this error 5 Update the IMM Firmware 6 Use CMOS clear jumper to clear CMOS 7 Trained service technician only Replace the system board W 3808003 W 3808003 Explanation Unable to retrieve the system configuration from the IMM Er...

Page 850: ...verity Warning User response Complete the following steps 1 Update all firmware including adapter firmware to the latest levels 2 If problem persists escalate to the next level of support W 3868002 W 3868002 Explanation IFM Error communicating with the IMM IFM may not be deployed correctly IFM Error communicating with the IMM IFM may not be deployed correctly Severity Error User response Complete ...

Page 851: ...re update that applies to this memory error The release notes will list the known problems the update addresses 3 If the previous steps do not resolve the problem at the next maintenance opportunity swap the DIMMs on the same memory channel one at a time to a different memory channel or Processor check service information for this product Install guide for population requirements for sparing parin...

Page 852: ...ectors are correctly populated for mirroring mode W 580A2 W 580A2 Explanation Invalid memory configuration for Sparing Mode Please correct memory configuration Unsupported DIMM Population for Spare Mode Severity Error User response Complete the following steps 1 If a DIMM connector error LED is lit resolve the failure 2 Make sure that the DIMM connectors are correctly populated for sparing mode ac...

Page 853: ...Registers Test Passed Explanation The test passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 405 001 000 BRCM TestMIIRegisters Test Passed Explanation The test passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v ...

Page 854: ...he test passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 405 004 000 BRCM TestInterrupt Test Passed Explanation The test passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of ...

Page 855: ...d Explanation The test passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 405 007 000 BRCM TestLEDs Test Passed Explanation The test passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest...

Page 856: ...The MII register test was canceled Severity Warning Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 405 802 000 BRCM TestEEPROM Test Aborted Explanation The EEPROM test was canceled Severity Warning Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Lat...

Page 857: ...nterrupt test was canceled Severity Warning Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 405 805 000 BRCM TestLoopbackMAC Test Aborted Explanation Loopback testing at the MAC layer was canceled Severity Warning Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Suppor...

Page 858: ...00 000 BRCM TestControlRegisters Test Failed Explanation A failure was detected while testing internal MAC registers Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD sectio...

Page 859: ...nks v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 405 902 000 BRCM TestEEPROM Test Failed Explanation A failure was detected while testing non volatile RAM Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found...

Page 860: ...Support Website v Latest level of DSA v Latest level of BMC IMM 405 904 000 BRCM TestInterrupt Test Failed Explanation A failure was detected while testing interrupts Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA D...

Page 861: ... Latest level of DSA v Latest level of BMC IMM 405 906 000 BRCM TestLoopbackPhysical Test Failed Explanation A failure was detected during the loopback test at the physical layer Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found ...

Page 862: ...un the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM DSA Brocade test results The following messages can result when you run the Brocade test 218 000 000 Brocade MemoryTest Passed Explanation The test passed Severity Event S...

Page 863: ...xplanation The test passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 218 003 000 Brocade PCILoopbackTest Passed Explanation The test passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Late...

Page 864: ...n The test passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 218 006 000 Brocade InternalLoopbackTest Passed Explanation The test passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest l...

Page 865: ...n The test was canceled Severity Warning Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 218 802 000 Brocade SerdesLoopbackTest Aborted Explanation The test was canceled Severity Warning Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of...

Page 866: ...est was canceled Severity Warning Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 218 805 000 Brocade SerdesEthLoopbackTest Aborted Explanation The test was canceled Severity Warning Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA...

Page 867: ... 3 Rerun the test 4 If the problem remains contact your IBM technical support representative Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 218 901 000 Brocade ExternalLoopbackTest Failed Explanation A failure was detected during the Loopback test Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following ...

Page 868: ...ort Website v Latest level of DSA v Latest level of BMC IMM 218 903 000 Brocade PCILoopbackTest Failed Explanation A failure was detected during the Loopback test Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Rerun the test 2 Verify whether the firmware is at proper level 3 Rerun the test 4 If the problem remains contact ...

Page 869: ...elated Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 218 905 000 Brocade SerdesEthLoopbackTest Failed Explanation A failure was detected during the Loopback test Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Rerun the test 2 Verify whether the firmware is at proper level 3 Rerun the test 4 If...

Page 870: ...int Panel Test Passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 180 801 000 Check point Panel Test Aborted Explanation Check point Panel Test Aborted BMC is unable to verify that the operator information panel cable is connected Severity Warning Serviceable Yes Recoverable No Auto...

Page 871: ...3 Run the test again 4 Replace the operator information panel assembly 5 Run the test again 6 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM DSA CPU stress test results The following messages can result when you run the CPU stress t...

Page 872: ...the next corrective action Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 089 802 000 CPU Stress Test Aborted Explanation CPU Stress Test Aborted System resource unavailability error Severity Warning Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Turn off and restart the system 2 Make sure that the DS...

Page 873: ...es Recoverable No Automatically notify Support No User response Complete the following steps 1 If the system has stopped responding turn off and restart the system and then run the test again 2 Make sure that the DSA Diagnostic code is at the latest level 3 Run the test again 4 Check system firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Even...

Page 874: ...ELXUCNA NIC PHY LoopBackTest Passed Explanation The test passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 516 002 000 ELXUCNA ELXUCNA NIC LED Beacon Test Passed Explanation The test passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v...

Page 875: ...esting at the physical layer was canceled Severity Warning Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 516 802 000 ELXUCNA ELXUCNA NIC LED Beacon Test Aborted Explanation Verification of status LEDs was canceled Severity Warning Serviceable No Recoverable No Automatically notify Support No Related...

Page 876: ...Website v Latest level of DSA v Latest level of BMC IMM 516 901 000 ELXUCNA NIC PHY LoopBackTest Failed Explanation A failure was detected during the loopback test at the physical layer Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be...

Page 877: ... 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM DSA EXA port ping test results The following messages can result when you run the EXA port ping test 401 000 000 EXA Port Ping Test Passed Explanation EXA Port Ping ...

Page 878: ...t Website v Latest level of DSA v Latest level of BMC IMM 401 802 000 EXA Port Ping Test Aborted Explanation EXA Port Ping Test Aborted Port connections may not be correct Severity Warning Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Remove power cables wait for 45 seconds reconnect and rerun the test 2 Make sure that the scalability c...

Page 879: ...4 Replace the scalability cable s for specified port s 5 If the problem remains contact your technical service representative Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM DSA hard drive test results The following messages can result when you run the hard drive test 217 000 000 HDD Test Passed Explanation HDD Stress Test Passed Severity Event Serviceable No Re...

Page 880: ...ite v Latest level of DSA v Latest level of BMC IMM 217 900 000 HDD Test Failed Explanation HDD Test Failed The hard drive self test detected a failure Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Check cable connections 2 Rerun the test 3 Verify the firmware is at the latest level 4 Rerun the test 5 If the problem remai...

Page 881: ...BMC IMM 406 001 000 IANet EEPROM Test Passed Explanation The test passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 406 002 000 IANet FIFO Test Passed Explanation The test passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Suppor...

Page 882: ...ssed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 406 800 000 IANet Registers Test Aborted Explanation Registers test was canceled Severity Warning Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level o...

Page 883: ...test was canceled Severity Warning Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 406 803 000 IANet Interrupts Test Aborted Explanation Interrupt test was canceled Severity Warning Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA ...

Page 884: ...bleshooting by symptom in the system Installation and Service Guide for the next corrective action Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 406 901 000 IANet EEPROM Test Failed Explanation A failure was detected during the EEPROM test Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1...

Page 885: ... was detected during the Interrupt test Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 Check interrupt assignments in the PC...

Page 886: ...s component 3 Rerun the test 4 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM DSA LSI hard drive test results The following messages can result when you run the LSI hard drive test 407 000 000 LSIESG DiskDefaultDiagnostic Test Passe...

Page 887: ...verity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Check cable connections 2 Rerun the test 3 Verify whether the firmware is at the latest level 4 Rerun the test 5 If the problem remains contact your IBM technical support representative Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM DSA Mella...

Page 888: ...ort Test Passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 408 800 000 MLNX MLNX_DiagnosticTestEthernetPort Test Aborted Explanation Port Test was canceled Severity Warning Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest le...

Page 889: ...s adapter might be faulty 3 Try replacing the adapter and repeating the test Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 408 901 000 MLNX MLNX_DiagnosticTestIBPort Test Failed Explanation Port Test Failed Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Make sure that the physical link...

Page 890: ...Standalone Memory Test Passed Explanation Quick Full Memory Test CPU 1 Passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 000 002 Standalone Memory Test Passed Explanation Quick Full Memory Test CPU 2 Passed Severity Event Serviceable No Recoverable No Automatically notify Suppo...

Page 891: ...l of BMC IMM 201 811 000 Standalone Memory Test Aborted Explanation Unable to Locate SMBIOS key _SM_ Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and...

Page 892: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 811 002 Standalone Memory Test Aborted Explanation Unable to Locate SMBIOS key _SM_ Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical se...

Page 893: ...pport Website v Latest level of DSA v Latest level of BMC IMM 201 812 000 Standalone Memory Test Aborted Explanation Memory test is not supported for this system Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact yo...

Page 894: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 812 002 Standalone Memory Test Aborted Explanation Memory test is not supported for this system Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your ...

Page 895: ...port Website v Latest level of DSA v Latest level of BMC IMM 201 813 000 Standalone Memory Test Aborted Explanation Chipset Error Can not turn OFF ECC error reporting in CPU Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remain...

Page 896: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 813 002 Standalone Memory Test Aborted Explanation Chipset Error Can not turn OFF ECC error reporting in CPU Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains ...

Page 897: ... IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 814 000 Standalone Memory Test Aborted Explanation Chipset Error Can not disable Scubbing feature for CPU Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem r...

Page 898: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 814 002 Standalone Memory Test Aborted Explanation Chipset Error Can not disable Scubbing feature for CPU Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains con...

Page 899: ...IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 815 000 Standalone Memory Test Aborted Explanation Program Error with Quick Memory Menu Option Selection Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem rem...

Page 900: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 815 002 Standalone Memory Test Aborted Explanation Program Error with Quick Memory Menu Option Selection Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains cont...

Page 901: ...IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 816 000 Standalone Memory Test Aborted Explanation Program Error with Full Memory Menu Option Selection Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem rema...

Page 902: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 816 002 Standalone Memory Test Aborted Explanation Program Error with Full Memory Menu Option Selection Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains conta...

Page 903: ...d Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 818 000 Standalone Memory Test Aborted Explanation Unable to Locate SMBIOS key _SM_ Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contac...

Page 904: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 818 002 Standalone Memory Test Aborted Explanation Unable to Locate SMBIOS key _SM_ Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical se...

Page 905: ...te v Latest level of DSA v Latest level of BMC IMM 201 819 000 Standalone Memory Test Aborted Explanation The start end address ranges in the restricted area of the memory Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains ...

Page 906: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 819 002 Standalone Memory Test Aborted Explanation The start end address ranges in the restricted area of the memory Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem ...

Page 907: ...ted Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 820 000 Standalone Memory Test Aborted Explanation Memory Upper limit is less than 16 Mbytes Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem rem...

Page 908: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 820 002 Standalone Memory Test Aborted Explanation Memory Upper limit is less than 16 Mbytes Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your tec...

Page 909: ...ite v Latest level of DSA v Latest level of BMC IMM 201 821 000 Standalone Memory Test Aborted Explanation Variable range MTRR registers are larger than fixed range MTRR registers Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem ...

Page 910: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 821 002 Standalone Memory Test Aborted Explanation Variable range MTRR registers are larger than fixed range MTRR registers Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the p...

Page 911: ...level Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 822 000 Standalone Memory Test Aborted Explanation Invalid MTRR service request Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remain...

Page 912: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 822 002 Standalone Memory Test Aborted Explanation Invalid MTRR service request Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical servic...

Page 913: ...A v Latest level of BMC IMM 201 824 000 Standalone Memory Test Aborted Explanation Node Interleave feature must be OFF Go to Setup and disable Node Interleave option and then re run the test Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If t...

Page 914: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 824 002 Standalone Memory Test Aborted Explanation Node Interleave feature must be OFF Go to Setup and disable Node Interleave option and then re run the test Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try th...

Page 915: ...ated Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 826 000 Standalone Memory Test Aborted Explanation BIOS Memory Controller has been disabled Go to Setup and Enable Memory Controller Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the te...

Page 916: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 826 002 Standalone Memory Test Aborted Explanation BIOS Memory Controller has been disabled Go to Setup and Enable Memory Controller Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2...

Page 917: ...IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 827 000 Standalone Memory Test Aborted Explanation BIOS ECC function has been disabled by BIOS Go to Setup and enable ECC generation Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each...

Page 918: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 827 002 Standalone Memory Test Aborted Explanation BIOS ECC function has been disabled by BIOS Go to Setup and enable ECC generation Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2...

Page 919: ...s v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 844 000 Standalone Memory Test Aborted Explanation Chipset Error Problem in masking MSR machine check control MASK registers Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each act...

Page 920: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 844 002 Standalone Memory Test Aborted Explanation Chipset Error Problem in masking MSR machine check control MASK registers Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the ...

Page 921: ... v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 845 000 Standalone Memory Test Aborted Explanation Chipset Error Problem clearing MSR machine check control registers Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If...

Page 922: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 845 002 Standalone Memory Test Aborted Explanation Chipset Error Problem clearing MSR machine check control registers Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem...

Page 923: ...level Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 859 000 Standalone Memory Test Aborted Explanation INVALID XSECSRAT type Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains conta...

Page 924: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 859 002 Standalone Memory Test Aborted Explanation INVALID XSECSRAT type Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service repre...

Page 925: ...IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 860 000 Standalone Memory Test Aborted Explanation No OEM0 type 1 found Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical servi...

Page 926: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 860 002 Standalone Memory Test Aborted Explanation No OEM0 type 1 found Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service repres...

Page 927: ...IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 861 000 Standalone Memory Test Aborted Explanation No SRAT type 1 found Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical servi...

Page 928: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 861 002 Standalone Memory Test Aborted Explanation No SRAT type 1 found Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service repres...

Page 929: ...M Support Website v Latest level of DSA v Latest level of BMC IMM 201 862 000 Standalone Memory Test Aborted Explanation No OEM1 structure found Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical serv...

Page 930: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 862 002 Standalone Memory Test Aborted Explanation No OEM1 structure found Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service rep...

Page 931: ...upport Website v Latest level of DSA v Latest level of BMC IMM 201 863 000 Standalone Memory Test Aborted Explanation No IBMERROR key in OEM1 structure Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technic...

Page 932: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 863 002 Standalone Memory Test Aborted Explanation No IBMERROR key in OEM1 structure Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical s...

Page 933: ...ks v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 864 000 Standalone Memory Test Aborted Explanation No GAS located in OEM1 Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technica...

Page 934: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 864 002 Standalone Memory Test Aborted Explanation No GAS located in OEM1 Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service repr...

Page 935: ...pport Website v Latest level of DSA v Latest level of BMC IMM 201 865 000 Standalone Memory Test Aborted Explanation No XSECSRAT key in OEM0 structure Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technica...

Page 936: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 865 002 Standalone Memory Test Aborted Explanation No XSECSRAT key in OEM0 structure Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical s...

Page 937: ...t Website v Latest level of DSA v Latest level of BMC IMM 201 866 000 Standalone Memory Test Aborted Explanation EFI SAL Invalid parameter from GetMemoryMap function Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contac...

Page 938: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 866 002 Standalone Memory Test Aborted Explanation EFI SAL Invalid parameter from GetMemoryMap function Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains conta...

Page 939: ...ted Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 867 000 Standalone Memory Test Aborted Explanation EFI SAL Buffer not allocated Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact ...

Page 940: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 867 002 Standalone Memory Test Aborted Explanation EFI SAL Buffer not allocated Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical servic...

Page 941: ... Website v Latest level of DSA v Latest level of BMC IMM 201 868 000 Standalone Memory Test Aborted Explanation EFI SAL Buffer allocated in GetMemoryMap too small Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact y...

Page 942: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 868 002 Standalone Memory Test Aborted Explanation EFI SAL Buffer allocated in GetMemoryMap too small Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact...

Page 943: ...BM Support Website v Latest level of DSA v Latest level of BMC IMM 201 869 000 Standalone Memory Test Aborted Explanation EFI SAL Invalid parameter from GetMemoryMap function Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remai...

Page 944: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 869 002 Standalone Memory Test Aborted Explanation EFI SAL Invalid parameter from GetMemoryMap function Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains conta...

Page 945: ...ted Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 870 000 Standalone Memory Test Aborted Explanation CPU Doamin in ACPI not valid Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact ...

Page 946: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 870 002 Standalone Memory Test Aborted Explanation CPU Doamin in ACPI not valid Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical servic...

Page 947: ...IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 871 000 Standalone Memory Test Aborted Explanation Data Mis compare encountered Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technic...

Page 948: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 871 002 Standalone Memory Test Aborted Explanation Data Mis compare encountered Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical servic...

Page 949: ...test level of DSA v Latest level of BMC IMM 201 877 000 Standalone Memory Test Aborted Explanation BIOS Sparing in Extended PCI reg must be OFF Go to setup and disable sparing Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem rema...

Page 950: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 877 002 Standalone Memory Test Aborted Explanation BIOS Sparing in Extended PCI reg must be OFF Go to setup and disable sparing Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If t...

Page 951: ...M Support Website v Latest level of DSA v Latest level of BMC IMM 201 878 000 Standalone Memory Test Aborted Explanation Sparing feature must be turned OFF Go to setup and turn the sparing feature OFF Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each act...

Page 952: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 878 002 Standalone Memory Test Aborted Explanation Sparing feature must be turned OFF Go to setup and turn the sparing feature OFF Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 I...

Page 953: ...pport Website v Latest level of DSA v Latest level of BMC IMM 201 885 000 Standalone Memory Test Aborted Explanation Processor does not support MTRR register manipulation Can not write to memory without cache Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after ...

Page 954: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 885 002 Standalone Memory Test Aborted Explanation Processor does not support MTRR register manipulation Can not write to memory without cache Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after eac...

Page 955: ...st level Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 886 000 Standalone Memory Test Aborted Explanation Memory Upper limit is less than 16 Mbytes Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If th...

Page 956: ...rt Website v Latest level of DSA v Latest level of BMC IMM 201 886 002 Standalone Memory Test Aborted Explanation Memory Upper limit is less than 16 Mbytes Severity Warning Serviceable No Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your tec...

Page 957: ...d BIOS uEFI are at the latest level Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 899 000 Standalone Memory Test Aborted Explanation Memory Diagnostics Test Aborted by user Severity Warning Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 899 001 Standalone...

Page 958: ...erable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest lev...

Page 959: ...IBM Support Website v Latest level of DSA v Latest level of BMC IMM 201 901 002 Standalone Memory Test Failed Explanation Memory Diagnostics Test Failed Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technic...

Page 960: ... DIMMS s mentioned in error one by one 6 Make sure that all DIMMs are enabled in the Configuration Setup Utility program 7 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM DSA memory stress test results The following messages can resu...

Page 961: ...sary 6 Run the memory diagnostic to identify the specific failing DIMM 7 If the failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 202 802 000 MemStr Test Aborted Explanation Memory size is insufficient to run the test At least 1 GB is req...

Page 962: ...y diagnostics to validate all memory 2 Make sure that the DSA Diagnostic code is at the latest level 3 Turn off the system and disconnect it from power 4 Reseat the memory cards and DIMMs 5 Reconnect the system to power and turn the system on 6 Run the test again 7 Execute the standard DSA memory diagnostics to validate all memory 8 If the failure remains refer to Troubleshooting by symptom in the...

Page 963: ...vel 4 Run the test again 5 Execute the standard DSA memory diagnostics to validate all memory 6 If the failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM DSA Nvidia GPU test results The following messages can result when you run the Nvidia...

Page 964: ...ion Nvidia GPU Query test passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 409 005 000 Nvidia DiagnosticServiceProvider Matrix Test Passed Explanation Nvidia GPU Matrix test passed Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Sup...

Page 965: ...er Diagnostic test was canceled Severity Event Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 409 803 000 Nvidia DiagnosticServiceProvider Bandwidth Test Aborted Explanation Nvidia GPU Bandwidth test was canceled Severity Warning Serviceable No Recoverable No Automatically notify Support No Related L...

Page 966: ...a GPU Matrix test was canceled Severity Warning Serviceable No Recoverable No Automatically notify Support No Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 409 806 000 Nvidia DiagnosticServiceProvider Binomial Test Aborted Explanation Nvidia GPU Binomial test was canceled Severity Warning Serviceable No Recoverable No Automatically notify Support No Related Li...

Page 967: ...rt Website v Latest level of DSA v Latest level of BMC IMM 409 903 000 Nvidia DiagnosticServiceProvider Bandwidth Test Failed Explanation Nvidia GPU Bandwidth Test Failed Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU Then power cycle the system ...

Page 968: ...t Website v Latest level of DSA v Latest level of BMC IMM 409 905 000 Nvidia DiagnosticServiceProvider Matrix Test Failed Explanation Nvidia GPU Matrix Test Failed Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU Then power cycle the system 2 Verif...

Page 969: ...r cable 4 Rerun the diagnostics using the same GPU on system that is known to be working A variety of system issues can cause diagnostic failure 5 If the problem remains contact your IBM technical support representative Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM DSA optical drive test results The following messages can result when you run the optical drive ...

Page 970: ...elated Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 215 802 000 Optical Drive Test Aborted Explanation Optical Drive Test Aborted A read error was encountered Severity Warning Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Insert a new CD or DVD into the drive and wait for 15 seconds for the media to be rec...

Page 971: ...ning Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Close the media tray and wait for 15 seconds for the media to be recognized Run the test again 2 Insert a new CD or DVD into the drive and wait for 15 seconds for the media to be recognized Rerun the test 3 Check the drive cabling for loose or broken connections at both ends or damage t...

Page 972: ...BM Support Website v Latest level of DSA v Latest level of BMC IMM 215 902 000 Optical Drive Test Failed Explanation Optical Drive Test Failed Read miscompare Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Insert a new CD or DVD into the drive and wait for 15 seconds for the media to be recognized Rerun the test 2 Check th...

Page 973: ...talled firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 5 Run the test again 6 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM DSA system management test results The follo...

Page 974: ...se Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 166 803 001 IMM I2C Test Aborted Explanation Node Busy Try later Severity Warning Se...

Page 975: ...ctions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 166 806 001 IMM I2C Test Aborted Explanation Timeout while processing command Severity Warning Servi...

Page 976: ...e actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 166 809 001 IMM I2C Test Aborted Explanation Request data truncated Severity Warning Serviceable ...

Page 977: ...nse Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 166 812 001 IMM I2C Test Aborted Explanation Parameter out of range Severity Warnin...

Page 978: ... Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 166 815 001 IMM I2C Test Aborted Explanation Invalid data field in Request Severity Wa...

Page 979: ...response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 166 818 001 IMM I2C Test Aborted Explanation Cannot execute duplicated request...

Page 980: ...ponse Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 166 821 001 IMM I2C Test Aborted Explanation Command response could not be provid...

Page 981: ...sponse Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 166 824 001 IMM I2C Test Aborted Explanation Cannot execute command Severity War...

Page 982: ... Website v Latest level of DSA v Latest level of BMC IMM 166 907 001 IMM I2C Test Failed Explanation IMM Indicates failure in PCA9545 4 Channel I2C Switch bus BUS 6 Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 s...

Page 983: ...atest level 3 Run the test again 4 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM DSA tape drive test results The following messages can result when you run the tape drive test 264 000 000 Tape Test Passed Explanation Tape Test Pass...

Page 984: ...ated Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 264 902 000 Tape Test Failed Explanation Tape Test Failed Media is not detected Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Clean the tape drive using the appropriate cleaning media and install new media 2 Run the test again 3 Make sure tha...

Page 985: ...C IMM 264 904 000 Tape Test Failed Explanation Tape Test Failed Drive hardware error Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Check the tape drive cabling for loose or broken connections or damage to the cable Replace the cable if damage is present 2 Clean the tape drive using the appropriate cleaning media and insta...

Page 986: ...Related Links v IBM Support Website v Latest level of DSA v Latest level of BMC IMM 264 906 000 Tape Test Failed Explanation Tape Test Failed Unrecognized error Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Clean the tape drive using the appropriate cleaning media and install new media 2 Run the test again 3 Make sure tha...

Page 987: ...site v Latest level of DSA v Latest level of BMC IMM 264 908 000 Tape Test Failed Explanation An error was found in getting tape capacity Severity Error Serviceable Yes Recoverable No Automatically notify Support No User response Complete the following steps 1 Make sure that medium is present 2 Clean the tape drive using the appropriate cleaning media and install new media Related Links v IBM Supp...

Page 988: ...972 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 989: ...ance contract Your IBM service technician will request that you upgrade your software and firmware if the problem has a documented solution within a software upgrade v If you have installed new hardware or software in your environment check http www ibm com systems info x86servers serverproven compat us to make sure that the hardware and software is supported by your IBM product v Go to http www i...

Page 990: ...Wide Web where you can get the latest technical information and download device drivers and updates To access these pages go to http www ibm com supportportal Getting help and information from the World Wide Web Up to date information about IBM products and support is available on the World Wide Web On the World Wide Web up to date information about IBM systems optional devices services and suppor...

Page 991: ... planetwide for support telephone numbers In the U S and Canada call 1 800 IBM SERV 1 800 426 7378 Hardware service and support You can receive hardware service through your IBM reseller or IBM Services To locate a reseller authorized by IBM to provide warranty service go to http www ibm com partnerworld and click Business Partner Locator For IBM support telephone numbers see http www ibm com plan...

Page 992: ...976 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 993: ...0504 1785 U S A INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not app...

Page 994: ...gistered trademark of The Open Group in the United States and other countries Important notes Processor speed indicates the internal clock speed of the microprocessor other factors also affect application performance CD or DVD drive speed is the variable read rate Actual speeds vary and are often less than the possible maximum When referring to processor storage real and virtual storage or channel...

Page 995: ...her This specification sets forth limits for particulates and gases that are intended to avoid such damage The limits must not be viewed or used as definitive limits because numerous other factors such as temperature or moisture content of the air can influence the impact of particulates or environmental corrosives and gaseous contaminant transfer In the absence of specific limits that are set for...

Page 996: ...ity standards If you experience difficulties when you use the PDF files and want to request a web based format or accessible PDF document for a publication direct your mail to the following address Information Development IBM Corporation 205 A015 3039 E Cornwallis Road P O Box 12195 Research Triangle Park North Carolina 27709 2195 U S A In the request be sure to include the publication part number...

Page 997: ...and grounded cables and connectors must be used in order to meet FCC emission limits IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment Unauthorized changes or modifications could void the user s authority to operate the equipment This device complies with Part 15...

Page 998: ...t den Schutzanforderungen der EU Richtlinie 2004 108 EG zur Angleichung der Rechtsvorschriften über die elektromagnetische Verträglichkeit in den EU Mitgliedsstaaten und hält die Grenzwerte der EN 55022 Klasse A ein Um dieses sicherzustellen sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen we...

Page 999: ...York 10504 914 499 1900 Der verantwortliche Ansprechpartner des Herstellers in der EU ist IBM Deutschland GmbH Technical Regulations Abteilung M372 IBM Allee 1 71139 Ehningen Germany Telephone 49 7032 15 2941 Email lugi de ibm com Generelle Informationen Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse A Japan VCCI Class A statement This is a Class A product based on the...

Page 1000: ...s greater than 20 A per phase Korea Communications Commission KCC statement This is electromagnetic wave compatibility equipment for business Type A Sellers and users need to pay attention to it This is for any areas other than home Russia Electromagnetic Interference EMI Class A statement People s Republic of China Class A electronic emission statement 984 System x3650 M5 Type 5462 Installation a...

Page 1001: ...Taiwan Class A compliance statement Notices 985 ...

Page 1002: ...986 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 1003: ... replacing 243 before you install a legacy operating system 47 blue screen capture feature overview 57 blue screen feature 57 Boot Manager 55 Boot Manager program 44 button presence detection 21 buttons system board 30 C cabling 131 12x3 5 inch drive backplane 144 3 5 inch drive backplane 142 8x3 5 inch drive backplane 142 the 16x2 5 inch hot swap drive backplane 135 the 24x2 5 inch hot swap drive...

Page 1004: ...system 81 event logs clearing 83 event logs methods for viewing 82 expansion slot locations 26 external connectors 29 F fan cage assembly removing 172 replacing 173 fans 13 FCC Class A notice 981 features 8 ServerGuide 47 Features on Demand 13 finding updated documentation 6 firmware updates 1 firmware updates 1 firmware server recovering 117 firmware updating 43 front view 19 front USB assembly r...

Page 1005: ...cal area network LAN 13 logging 59 M management system 13 media cage installing 178 removing 176 memory 13 memory module installing 167 removing 166 memory support 13 menu choices Setup utility 49 messages diagnostic POST UEFI 817 method 119 methods viewing event logs 82 microprocessor 13 problems 96 removing 258 replacing 264 model name location 116 N New Zealand Class A statement 981 NMI button ...

Page 1006: ... two hard disk drive kit 197 air baffle 149 battery system 243 components 131 dedicated slotless RAID controller 184 DIMM 170 EIA 216 fan cage assembly 173 front USB assembly 152 heat sink 264 heat sink retention module 275 hot swap ac power supply 229 hot swap drive backplane 233 hot swap fan 175 hot swap hard disk drive 155 LCD system information display panel 248 microprocessor 264 operator inf...

Page 1007: ...ent log deassertion event 81 systems management 13 systems management tool IBM Systems Director 16 T Taiwan Class A electronic emission statement 985 telecommunication regulatory statement 980 telephone numbers 975 test log viewing 87 thermal grease 273 tools call home 87 tools diagnostic 76 top cover removing 146 replacing 147 trademarks 978 troubleshooting 71 symptom 88 turning off the server 40...

Page 1008: ...992 System x3650 M5 Type 5462 Installation and Service Guide ...

Page 1009: ......

Page 1010: ... Part Number 00AK781 Printed in USA 1P P N 00AK781 ...

Reviews: