806f0207-2584ffff
[ProcessorElementName] has Failed with FRB1/BIST condition. (All CPUs)
Explanation:
This message is for the use case when an implementation has detected a Processor Failed - FRB1/BIST
condition.
May also be shown as 806f02072584ffff or 0x806f02072584ffff
Severity:
Error
Alert Category:
Critical - CPU
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0044
SNMP Trap ID:
40
Automatically notify Support:
Yes
User response:
1.
Make sure that the latest levels of firmware and device drivers are installed for all adapters and standard devices
such as Ethernet and storage adapters. Important: Some cluster solutions require specific code levels or
coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is
supported for the cluster solution before you update the code.
2.
Update the firmware (UEFI and IMM) to the latest level (Updating the firmware).
3.
Run the DSA program.
4.
Remove the adapter to see if the problem is follwed adapter. if not, replace the adapter.
5.
(Trained technician only) Replace microprocessor n.
6.
(Trained technician only) Replace the system board. (n = microprocessor number)
806f020d-0400ffff
Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive 0)
Explanation:
This message is for the use case when an implementation has detected an Array Failure is Predicted.
May also be shown as 806f020d0400ffff or 0x806f020d0400ffff
Severity:
Warning
Alert Category:
System - Predicted Failure
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0168
SNMP Trap ID:
27
Automatically notify Support:
Yes
User response:
1.
Run the hard disk drive diagnostic test on drive n.
2.
Reseat the following components: a. Hard disk drive b. Cable from the system board to the backplane.
3.
Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard
disk drive. b. Cable from the system board to the backplane. c. Hard disk drive backplane. (n = hard disk drive
number)
806f0207-2584ffff • 806f020d-0400ffff
478
System x3650 M5 Type 5462: Installation and Service Guide
Summary of Contents for System x3650 M5
Page 1: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Page 8: ...vi System x3650 M5 Type 5462 Installation and Service Guide ...
Page 16: ...xiv System x3650 M5 Type 5462 Installation and Service Guide ...
Page 58: ...42 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 86: ...70 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 320: ...304 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 832: ...816 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 988: ...972 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 992: ...976 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1001: ...Taiwan Class A compliance statement Notices 985 ...
Page 1002: ...986 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1008: ...992 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1009: ......
Page 1010: ... Part Number 00AK781 Printed in USA 1P P N 00AK781 ...