80010202-0701ffff
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted. (CMOS
Battery)
Explanation:
This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102020701ffff or 0x800102020701ffff
Severity:
Error
Alert Category:
Critical - Voltage
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0480
SNMP Trap ID:
1
Automatically notify Support:
Yes
User response:
If the specified sensor is CMOS battery, replace the system battery. If the specified sensor is Planar
3.3V or Planar 5V, (trained technician only) replace the system board. If the specified sensor is Planar 12V, complete
the following steps until the problem is solved:
1.
Check power supply n LED.
2.
Remove the failing power supply.
3.
Follow actions in "Power Problems and Solving Power Problems".
4.
(Trained technician only) Replace the system board. (n = power supply number)
80010204-1d01ffff
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted. (Fan
1A/1B Tach)
Explanation:
This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102041d01ffff or 0x800102041d01ffff
Severity:
Error
Alert Category:
Critical - Fan Failure
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0480
SNMP Trap ID:
11
Automatically notify Support:
No
User response:
1.
Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system board.
2.
Replace the failing fan. (n = fan number)
80010202-0701ffff • 80010204-1d01ffff
Appendix A. Integrated management module II (IMM2) error messages
365
Summary of Contents for System x3650 M5
Page 1: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Page 8: ...vi System x3650 M5 Type 5462 Installation and Service Guide ...
Page 16: ...xiv System x3650 M5 Type 5462 Installation and Service Guide ...
Page 58: ...42 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 86: ...70 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 320: ...304 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 832: ...816 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 988: ...972 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 992: ...976 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1001: ...Taiwan Class A compliance statement Notices 985 ...
Page 1002: ...986 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1008: ...992 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1009: ......
Page 1010: ... Part Number 00AK781 Printed in USA 1P P N 00AK781 ...