
3.
If the problem is related to a DIMM, replace the failing DIMM indicated by the error LEDs.
4.
If the problem occurs on the same DIMM connector, swap the affected DIMMs (as indicated by the error LEDs
on the system board or the event logs) to a different memory channel or microprocessor.
5.
If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any
foreign material or is damaged, replace the system board.
6.
(Trained service technician only) Remove the affected microprocessor and check the microprocessor socket pins
for any damaged pins. If a damage is found, replace the system board.
7.
(Trained service technician only) If the problem is related to microprocessor socket pins, replace the system
board.
806f030c-2016ffff
Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
(DIMM 22)
Explanation:
This message is for the use case when an implementation has detected a Memory Scrub failure.
May also be shown as 806f030c2016ffff or 0x806f030c2016ffff
Severity:
Error
Alert Category:
Critical - Memory
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0136
SNMP Trap ID:
41
Automatically notify Support:
No
User response:
Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
2.
Make sure that the DIMMs are firmly seated and no foreign material is found in the DIMM connector. Then,
retry with the same DIMM.
3.
If the problem is related to a DIMM, replace the failing DIMM indicated by the error LEDs.
4.
If the problem occurs on the same DIMM connector, swap the affected DIMMs (as indicated by the error LEDs
on the system board or the event logs) to a different memory channel or microprocessor.
5.
If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any
foreign material or is damaged, replace the system board.
6.
(Trained service technician only) Remove the affected microprocessor and check the microprocessor socket pins
for any damaged pins. If a damage is found, replace the system board.
7.
(Trained service technician only) If the problem is related to microprocessor socket pins, replace the system
board.
806f030c-2016ffff
Appendix A. Integrated management module II (IMM2) error messages
507
Summary of Contents for System x3650 M5
Page 1: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Page 8: ...vi System x3650 M5 Type 5462 Installation and Service Guide ...
Page 16: ...xiv System x3650 M5 Type 5462 Installation and Service Guide ...
Page 58: ...42 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 86: ...70 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 320: ...304 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 832: ...816 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 988: ...972 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 992: ...976 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1001: ...Taiwan Class A compliance statement Notices 985 ...
Page 1002: ...986 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1008: ...992 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1009: ......
Page 1010: ... Part Number 00AK781 Printed in USA 1P P N 00AK781 ...