a.
Identify which release lever is labeled as the first release lever to open and
open it.
b.
Open the second release lever on the microprocessor socket.
c.
Open the microprocessor retainer.
Attention:
Do not touch the microprocessor contacts. Contaminants on
the microprocessor contacts, such as oil from your skin, can cause
connection failures between the contacts and the socket.
9.
Remove the microprocessor from the socket.
a.
Select the empty installation tool and ensure that the handle is in the
unlocked position. If the installation tool handle is not in the unlocked
position, use the following instructions for your installation tool:
v
▌1▐
lift the interlock latch and hold it up while you
▌2▐
twist the
microprocessor installation tool handle counterclockwise to the unlocked
position, and then release the interlock latch. The following illustration
of the installation tool shows the location of the interlock latch and
counterclockwise rotation of the handle before loading the
microprocessor.
1
3
2
Microprocessor
release lever
Microprocessor
release lever
Figure 218. Microprocessor socket levers and retainer disengagement
Chapter 5. Removing and replacing components
261
Summary of Contents for System x3650 M5
Page 1: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Page 8: ...vi System x3650 M5 Type 5462 Installation and Service Guide ...
Page 16: ...xiv System x3650 M5 Type 5462 Installation and Service Guide ...
Page 58: ...42 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 86: ...70 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 320: ...304 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 832: ...816 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 988: ...972 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 992: ...976 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1001: ...Taiwan Class A compliance statement Notices 985 ...
Page 1002: ...986 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1008: ...992 System x3650 M5 Type 5462 Installation and Service Guide ...
Page 1009: ......
Page 1010: ... Part Number 00AK781 Printed in USA 1P P N 00AK781 ...