B.8
Current transducers and accessories
B.8.1
Current transducers
Gxxx: Current Transducers (Option, to be ordered separately)
Current loop (compensated) current transducers (CT) using an extremely accurate zero flux detector with excellent linearity and low temperature
drift. Electrostatic shield between primary and secondary circuit, with low insertion loss and high immunity to electrostatic and magnetic fields.
To be used with CT power supply and burden resistor to measure high frequency currents.
IT 60-S Ultrastab
IT 700-S Ultrastab
IT 1000-S/SP1 Ultrastab
IT 200-S Ultrastab
IT 400-S Ultrastab
y
x
S
D
-
+
Power
Amplifier
Output
Amplifier
Standard
Resistor
I
out
I
p
I
p
I
S
N
=
Flux
Detector
Figure B.34:
Simplified block diagram and image
Isolation
150 V RMS reinforced isolation
300 V RMS single isolation
Linearity
≤ 3 ppm
Temperature coefficient of I
oe
≤ 0.5 ppm/
o
C (
±
0.9 ppm /
o
F)
Supply voltages
+ 15 V (
±
5%) and
-
15 V (
±
5%), ≤ 80 mA + I
s
Original manufacturers part number
LEM ULTRASTAB series
Operating temperature range
10
o
C to +50
o
C (50 °F to 122 °F)
Device
IT 1000
-
S/SP1
IT 700
-
S
IT400
-
S
IT 200
-
S
IT 60
-
S
Primary nominal current DC
1000 A DC
700 A DC
400 A DC
200 A DC
60 A DC
Primary nominal current AC
707 A RMS
495 A RMS
282 A RMS
141 A RMS
42 A RMS
Secondary nominal current DC
1000 mA DC
400 mA RMS
200 mA RMS
200 mA RMS
100 mA DC
Conversion ratio (N)
1000:1
1750:1
2000:1
1000:1
600:1
Burden recommendation
HBR1.0
HBR2.5
HBR2.5
HBR2.5
HBR10.0
dI/dt risetime
≥100 A/µs
≥100 A/µs
≥100 A/µs
≥100 A/µs
≥25 A/µs
Small signal bandwidth (
-
3 dB)
500 kHz
500 kHz
500 kHz
500 kHz
800 kHz
Weight (typical)
1.0 kg (35.3 oz)
0.8 kg (28.2 oz)
0.3 kg (10.6 oz)
0.3 kg (10.6 oz)
0.3 kg (10.6 oz)
Dimensions
Cable diameter
30 mm (1.18")
30 mm (1.18")
26 mm (1.02")
26 mm (1.02")
26 mm (1.02")
Width
128 mm (5,03”)
128 mm (5,03”)
93 mm (3,66”)
93 mm (3,66”)
93 mm (3,66”)
Height
106 mm (4,17”)
106 mm (4,17”)
77.7 mm (3,05”)
77.7 mm (3,05”)
77.7 mm (3,05”)
Depth
85 mm (3,34”)
67 mm (2,63”)
57 mm (2,24”)
57 mm (2,24”)
57 mm (2,24”)
GEN3i
I3763-3.1 en HBM: public
751