Basic Configuration
146
Hot Swappable IP I/O Boards and SFPs
Hot Swappable IP I/O Boards and SFPs
IP I/O boards are hot swappable. SFPs are also hot swappable on each board, provided the
SFP modules are all of the same (supported) type. Swapping an SFP module on a board
requires that the new module be identical to the one being replaced.
Troubleshooting
When the Frame IP Address is entered into a browser, the IP SFP Statistics web page
provides useful data for determining if the bandwidth for an SFP has been exceeded in
relation to the image format speed (Gb/s), Board SFP Speed (Gb/s), and Streams/SFPs mode
selected (e.g. 4 inputs/2 outputs, 8 inputs, 2 outputs).
Additionally, it can be determined if an SFP is passing video; if an SFP is configured and the
Gb/s throughput column displays a number lower than the configured SFP speed, there
may be an issue with the SFP module or the bandwidth has been exceeded.
Open the GV K-Frame Web Access pages by entering the Frame IP Address into a browser
on the system network and selecting
IP SFP Statistics
on the left.
Note:
The Phy Link/Lock Status column (far right) in the SFP Statistics
Web Access page, provides Ethernet link status. If the status is “Up”, the
Ethernet link is up and locked, the speed is matched between the
switcher and the external device, and it is working properly. If the status
is “Down”, there is either an issue with the link connection or a mis-match
of Ethernet link speed.
In the example following, the SFP Stream mode type is 8 inputs/4 outputs and the Rx
Throughput is over 10Gb/s, requiring a 25Gb/s SFP IP board configuration. The image
format speed coupled with the 8/4 mode selection requires 25Gb/s of bandwidth. The Link
Speed (Gb/s) column (second from the right) shows that the IP board SFPs are configured as
25Gb/s.
CAUTION: Exceeding the SFP bandwidth will result in a signal loss for
the associated SFP ports.
Summary of Contents for KARRERA
Page 47: ...Installation Service Manual 23 15 RU Dimensions Side View ...
Page 49: ...Installation Service Manual 25 15RUVideo Processor Views 15 RU Front View withDoor Removed ...
Page 50: ...Frame Installation 26 15 RU Rear ViewIP Gearbox Conversion 15RU Front View withDoor Removed ...
Page 52: ...Frame Installation 28 PowerSupplyFrameDimensions TopView ...
Page 171: ...Installation Service Manual 147 ...
Page 204: ...Basic Configuration 180 ...
Page 208: ...Basic Configuration 184 green ...
Page 234: ...Basic Configuration 210 ...
Page 265: ...Installation Service Manual 241 ...
Page 296: ...External Interfaces 272 PBus and GPI Enables ...
Page 366: ...Maintenance 342 ...
Page 367: ...Installation Service Manual 343 ...
Page 368: ...Maintenance 344 ...