Installation & Service Manual
183
Set Source Names with External Ethernet Tally
Set Source Names with External Ethernet Tally
Support for setting source names through external Ethernet tally clients can be added by
tally client developers. Once enabled, the tally client can send data to the Frame that will
modify any or all source names in the system, including the Engineering Names for each
source. Additionally, the Control Panel, OLED, and Menu names for each logical source in
each suite can be set externally.
1
Select
Eng Setup, Ports & Devices, Tally Ports
.
2
Select an Ethernet Tally IP Address data pad, enter the IP Address of the external tally
system in the pop-up keypad, and select
Enter
.
The Connection Status indicator for that tally contributor turns green when connected. The
Tally Clients pane (right) displays which suites have external Ethernet tally contribution
(S1-S4) and tally system information.
Connection Status Indicator colors:
•
White—no external Ethernet tally connection
•
Green—external Ethernet tally client is connected
•
Red—external Ethernet tally connection error
3
Select the Connection Status
Enable
button to connect to the external Ethernet tally
client.
4
Enable the Source Name Control by selecting the
Enable
button for the external
Ethernet tally connection.
Note:
Source name control is enabled only when the Connection Status
and Source Name Control
Enable
buttons are both enabled (highlighted
Summary of Contents for KARRERA
Page 47: ...Installation Service Manual 23 15 RU Dimensions Side View ...
Page 49: ...Installation Service Manual 25 15RUVideo Processor Views 15 RU Front View withDoor Removed ...
Page 50: ...Frame Installation 26 15 RU Rear ViewIP Gearbox Conversion 15RU Front View withDoor Removed ...
Page 52: ...Frame Installation 28 PowerSupplyFrameDimensions TopView ...
Page 171: ...Installation Service Manual 147 ...
Page 204: ...Basic Configuration 180 ...
Page 208: ...Basic Configuration 184 green ...
Page 234: ...Basic Configuration 210 ...
Page 265: ...Installation Service Manual 241 ...
Page 296: ...External Interfaces 272 PBus and GPI Enables ...
Page 366: ...Maintenance 342 ...
Page 367: ...Installation Service Manual 343 ...
Page 368: ...Maintenance 344 ...