Installation & Service Manual
331
Downgrade the IP Board ARM Software
d
Select
Frame Message Log
(left), then
Current
(it can take several minutes for data
to transfer to the Frame Message Log, continue to select the
Frame Message Log
button until all boards report the new version).
CAUTION: Do not power cycle or reset the Frame until the following result
is displayed, showing that all boards are updated. Doing so
can corrupt the SD card.
Results will be similar to the following example in the Message Log, reporting the new
version for
all
boards:
* 28 Nov 2018 14:55:09 (72378) PTP: Set to RUN from
WAIT_FOR_RUN_AFTER_RESET
* 28 Nov 2018 14:55:06 (72378) PTP reports SD Image version: V14.3.1
Downgrade the IP Board ARM Software
When downgrading the switcher software, the GV K-Frame X and V-series systems with IP
boards installed require the Board ARM software version to be downgraded to match using
the ‘Flash All SD Cards’ console command.
1
Install the
earlier
version of the software (see the
Kayenne/Karrera/GV Korona Release
Notes
for specific instructions).
2
Open the Frame door and attach the serial console cable to the front edge of the
Controller board.
3
Upgrade or verify that the board FPGA HADs are up to date
.
4
To check the HAD status, enter checkHADs at the prompt:
->checkHADs
Result:
HADs up-to-date:
value = 1 = 0x1
HADs out-of-date:
value = 0 = 0x0
5
If the HADs are out of date, continue to the next steps.
6
Enter the console menu by typing consoleMenu at the prompt:
->consoleMenu
Result:
7
Enter the number nine [9] for the Debug menu, at the prompt:
->9
Result:
CAUTION: Do not downgrade to switcher software versions earlier
than 14.1.0 from 14.3.x with IP I/O boards installed.
Summary of Contents for KARRERA
Page 47: ...Installation Service Manual 23 15 RU Dimensions Side View ...
Page 49: ...Installation Service Manual 25 15RUVideo Processor Views 15 RU Front View withDoor Removed ...
Page 50: ...Frame Installation 26 15 RU Rear ViewIP Gearbox Conversion 15RU Front View withDoor Removed ...
Page 52: ...Frame Installation 28 PowerSupplyFrameDimensions TopView ...
Page 171: ...Installation Service Manual 147 ...
Page 204: ...Basic Configuration 180 ...
Page 208: ...Basic Configuration 184 green ...
Page 234: ...Basic Configuration 210 ...
Page 265: ...Installation Service Manual 241 ...
Page 296: ...External Interfaces 272 PBus and GPI Enables ...
Page 366: ...Maintenance 342 ...
Page 367: ...Installation Service Manual 343 ...
Page 368: ...Maintenance 344 ...