Basic Configuration
174
outputs for external devices or other specific uses. Output Blanking is provided in the Eng
Setup, Outputs menu to allow this specialized control.
You can also choose to pass ancillary data or regenerate blanking for all Aux or all Fixed
outputs in the Outputs menu. For example, if you selected All Aux Outputs to Pass Ancillary
Data in the Outputs menu, you could then set individual aux outputs to Regenerate
Blanking. This allows fast configuration of a large number of outputs.
Configure Aux Output Blanking
Configure Aux Output Blanking for all or individual Aux outputs to pass or blank ancillary
data in the Eng Setup, Outputs menu.
1
In the Eng Setup, Outputs menu, select either
Output
or
Modular I/O
.
2
Select an Aux output from the Physical Outputs scrolling list or select
Aux
in the Output
Type pane to display the Aux Outputs menu.
3
Result: The Logical Aux Bus selection pane is displayed (center) along with other Aux
output parameter functions.
4
In the All Aux Outputs pane (right), select either the
Pass Ancillary Data
or
Regen
Blanking
button to configure all Aux outputs.
With all outputs set to pass or blank ancillary data, you can change individual outputs
to the opposite state.
5
Select any output in the Logical Aux Buses scrolling list (center).
6
Select either the
Pass Ancillary Data
or
Regen Blanking
buttons under the Output
Blanking label to set Output Blanking for an individual output.
7
Outputs set to blanking have the word Regen in the upper right of the data pad (all
other states are blank), in the Physical Outputs scrolling list.
Configure Fixed Output Blanking
Configure Fixed Output Blanking for all or individual Fixed outputs to pass or blank ancillary
data in the Eng Setup, Outputs menu.
1
In the Eng Setup, Outputs menu, select either
Output
or
Modular I/O
.
2
Select a Fixed output from the Physical Outputs scrolling list or select
Fixed
in the
Output Type pane to display the Fixed Outputs menu.
3
Result: The Logical Sources/ Fixed Sources scrolling list is displayed (right) along with
other Fixed output parameter functions.
4
In the All Aux Outputs pane (right), select either the
Pass Ancillary Data
or
Regen
Blanking
button to configure all Aux outputs.
With all outputs set to pass or blank ancillary data, you can change individual outputs
to the opposite state (see
About Passing/Blanking Ancillary Data for Individual
Outputs
).
5
Select any output in the Logical Aux Buses scrolling list (center).
6
Select either the
Pass Ancillary Data
or
Regen Blanking
buttons under the Output
Blanking label to set Output Blanking for an individual output.
Outputs set to blanking have the word Regen in the upper right of the data pad (all other
states are blank), in the Physical Outputs scrolling list.
Summary of Contents for KARRERA
Page 47: ...Installation Service Manual 23 15 RU Dimensions Side View ...
Page 49: ...Installation Service Manual 25 15RUVideo Processor Views 15 RU Front View withDoor Removed ...
Page 50: ...Frame Installation 26 15 RU Rear ViewIP Gearbox Conversion 15RU Front View withDoor Removed ...
Page 52: ...Frame Installation 28 PowerSupplyFrameDimensions TopView ...
Page 171: ...Installation Service Manual 147 ...
Page 204: ...Basic Configuration 180 ...
Page 208: ...Basic Configuration 184 green ...
Page 234: ...Basic Configuration 210 ...
Page 265: ...Installation Service Manual 241 ...
Page 296: ...External Interfaces 272 PBus and GPI Enables ...
Page 366: ...Maintenance 342 ...
Page 367: ...Installation Service Manual 343 ...
Page 368: ...Maintenance 344 ...