85
Installation & Service Manual
Ethernet Switch
Ethernet Switch
The Ethernet switch built into the GV K-Frame XP auto-detects speed and polarity, and is
10/100/1000 Mbps capable. Either straight-through or crossover Ethernet cabling can be
used. Available Ethernet connectors may be connected to the Facility LAN or other devices,
as needed. However, should the Frame power down, the internal Ethernet switch will also
power down, interrupting communication to devices connected to that Frame’s internal
Ethernet switch. Only connect devices that are system related.
Customer Supplied Ethernet Routers and Switches
Existing facility Ethernet switches can be used in conjunction with a switcher system. If
connecting to a network area outside that used by the switcher system, use of an
appropriately configured Ethernet Router is strongly advised. This reduces network traffic
on the GV K-Frame XP network and keeps it isolated. Any Ethernet switches added
specifically for use with the switcher system should be 1000 Mbps capable for the most
efficient operation.
Ethernet Specifications
Cables
Type
10BaseT, 100BaseT, 1000BaseT compatible
Category 5 cable, 8 conductor twisted pair
The system will work at lower ratings with reduced
performance. 1000BaseT components are highly
recommended.
Connectors
RJ-45 male connector at each end of cable.
Length
100BaseT, 1000BaseT: 328 ft. (100 m) maximum.
10BaseT: 984 ft. (300 m) maximum.
Use additional switches to exceed maximum cable
runs.
Switch
Speed
10/100/1000 Mbps
Ports
RJ-45 auto-negotiating 10/100/1000 Mbps; number of
ports required is dependent upon system size. Frame
and PCU ports are capable of 1000 Mbps. Using a 1000
Mbps Ethernet switch enhances Image Store transfer
speeds.
Unmanaged
Recommended. Configuration not required, but does
not provide remote monitoring capability.
Managed
May be used. Requires configuration, but offers remote
monitoring capability.
To integrate GV K-Frame XP devices into an existing network, ask the local network
administrator for that network’s subnet mask. Before changing IP addresses always set the
subnet masks of the GV K-Frame XP devices to the mask of the local network.
Summary of Contents for KARRERA
Page 47: ...Installation Service Manual 23 15 RU Dimensions Side View ...
Page 49: ...Installation Service Manual 25 15RUVideo Processor Views 15 RU Front View withDoor Removed ...
Page 50: ...Frame Installation 26 15 RU Rear ViewIP Gearbox Conversion 15RU Front View withDoor Removed ...
Page 52: ...Frame Installation 28 PowerSupplyFrameDimensions TopView ...
Page 171: ...Installation Service Manual 147 ...
Page 204: ...Basic Configuration 180 ...
Page 208: ...Basic Configuration 184 green ...
Page 234: ...Basic Configuration 210 ...
Page 265: ...Installation Service Manual 241 ...
Page 296: ...External Interfaces 272 PBus and GPI Enables ...
Page 366: ...Maintenance 342 ...
Page 367: ...Installation Service Manual 343 ...
Page 368: ...Maintenance 344 ...